Hydrotech 785UF Quick Setup Manual

Page 1
785UF Valve Softener Quick Set Up Manual
Step 1 – Inspection
Check to make sure you got everything supplied by factory and there is no visible or concealed damage. In case of missing items, please contact customer service immediately and have the Product Serial # handy. (Product Serial # can be found at the back of the control valve, see below)
The items you will expect are:
1. Tank with Softener Media loaded
2. Control Valve
3. Parts Kit
4. Brine Tank (Round or Square ) and Components
3. Parts Kit
3/4” Elbow Fitting X 2
Product Serial #
Bypass Tool
Set of Injectors
1. Tank with Softener
Media loaded
Spill Cap
D-Tube
4. Brine Tank (Round or Square ) and Components
Brine Tank (Round or Square)
2. Control Valve
Brine Elbow
Bypass Test Port Clip X 2
Drain Hose Fitting
Drain Clip
Bypass
Bypass Cllips X 2
Brine Tank Tubing
1” Straight Fitting X 2
Upper Basket/ Strainer
Brine line Plug ((used for Filters))
Grease port Orings using brush (not included) or your finger (Make sure to wear protective gloves)
Set of Washers
Step 2 – Installing Valve to the Tank
Select a Installation location and make sure there is access to 110V power outlet and drain line. Lube the bottom Valve Orings with the grease supplied, Attach the Upper Basket. Unscrew the spill cap. Carefully Slide the D-Tube inside the Valve and Screw the Valve inside the Tank such that the power cord doesnt get caught between the valve and the tank. Make sure the D-Tube slides inside the valve.
Transformer
Grease Packet
Grid Legs (3 for Round and 4 for Square)
Grid (Round or Square)
Unscrew Spill Cap
D-Tube
Brine Well/ Safety Float
Brine Tank Lid
Attach Upper Basket
CAUTION: Make sure the power cord of the valve doesnt get caught between the threads
Page 2
Step 3 – Assembling Brine Tank
'
a. Attach the three brine grid legs to grid plate. The legs will snap on to the tabs of the salt plate making a “click” sound. For square brine tank there are four legs.
b. Insert the brine well assembly inside the grid plate as well below.
c. Drop the brine grid with brine well inside the brine tank such that the nut fitting
faces the hole on the brine tank. Then press the grid evenly inside the brine tank until the brine grid legs touches the bottom of the brine tank.
d. Take the brine tube and insert the nut and plastic sleeve as shown below.
Insert Sleeve
e. Insert the tube in the float assembly elbow and hand tighten the nut. In many cases the brine line already come installed from the factory. Leave the other end of the brine line tube inside the brine tank
f. For installation of brine tank at the installation site, pull the other end of the brine tube from the hole on the brine tank. The completed assembly is shown below.
IMPORTANT: IN ROUND BRINE TANK, IT IS IMPORTANT TO ALIGN THE HANDLE TO THE BRINE WELL AS SHOWN
The hole in the brine tank should line up with the brine line as shown for round and square brine tank.
Step 5 – Power and Program Valve
Key Pad Conguration
SETTINGS This function is to enter the basic set up information required at the time of installation.
MANUAL This function is to initiate an immediate or delayed manual REGEN regeneration.
DOWN / Increase or decrease the value of the settings while in the UP programming mode.
6(77,1*60$18$/
5(*(1
83
2:1
Hole
Settings Press SETTINGS key (3 SECONDS / BEEP)
TIME OF DAY
12:01 PM
Press SETTINGS key
Press SETTINGS key
MONTH
AUGUST
Press SETTINGS key
Press SETTINGS key
YEAR
2016
DAY
Step 4 – Attaching Brine Tubing to the Valve
Put insert inside the brine tubing
SALT SETTING
Press SETTINGS key
SET HARDNESS
20 GRAINS
Press SETTINGS key
SET PEOPLE
4
Press SETTINGS key
SALT SETTING
HIGH EFFICIENCY
STANDARD
IRON & MN
21
Press SETTINGS key
Press SETTINGS key
WATER TYPE
MUNICIPAL
WELL / OTHER
Press SETTINGS key
REGEN TIME
2:00 AM
Press SETTINGS key
PROGRAMMING
COMPLETE
Choose HIGH EFFICIENCY to minimize salt usage. Your system will regenerate a little more often but your salt usage can be reduced by 20% compared to the STANDARD setting. Choose STANDARD when you need to maximize your capacity but still operate the system with good efficiency. Choose IRON & MN if you have problem water containing these minerals. The high salt setting will be needed since these minerals are more difficult to clean out of the resin bed. Note: A resin cleaner will also need to periodically added to the brine tank to insure proper operation.
WATER TYPE
This setting will determine if the BACKWASH OVERIDE function will be on or off. Select MUNICIPAL if the water source is clean (<1NTU turbidity) and the system will skip the back wash cycle based on the setting in BACKWASH OVERIDE. Select WELL / OTHER if any Iron or Manganese is present or if the water source is not clean (< 1NTU turbidity). The system will back wash every time. his setting determines the time of day to perform a scheduled regeneration.
TOLL-FREE: 1-877-288-9888
Regina, SK • Cambridge, ON • Carmel, IN • Fridley, MN • Phoenix, AZ
www.hydrotechwater.com
Follow the Instruction Manual to Complete the Installation of the Product