785UF Valve Softener
Quick Set Up Manual
Step 1 – Inspection
Check to make sure you got everything supplied by factory and there is no visible or concealed damage. In case of missing items, please contact customer service immediately
and have the Product Serial # handy. (Product Serial # can be found at the back of the control valve, see below)
The items you will expect are:
1. Tank with Softener Media loaded
2. Control Valve
3. Parts Kit
4. Brine Tank (Round or Square ) and Components
3. Parts Kit
3/4” Elbow
Fitting X 2
Product Serial #
Bypass Tool
Set of Injectors
1. Tank with Softener
Media loaded
Spill Cap
D-Tube
4. Brine Tank (Round or Square ) and Components
Brine Tank
(Round or
Square)
2. Control Valve
Brine
Elbow
Bypass Test Port Clip X 2
Drain Hose
Fitting
Drain Clip
Bypass
Bypass
Cllips X 2
Brine Tank
Tubing
1” Straight
Fitting X 2
Upper Basket/
Strainer
Brine line Plug ((used for Filters))
Grease port Orings using brush (not included) or
your finger (Make sure to wear protective gloves)
Set of
Washers
Step 2 – Installing Valve to the Tank
Select a Installation location and make sure there
is access to 110V power outlet and drain line. Lube
the bottom Valve Orings with the grease supplied,
Attach the Upper Basket. Unscrew the spill cap.
Carefully Slide the D-Tube inside the Valve and
Screw the Valve inside the Tank such that the power
cord doesnt get caught between the valve and the
tank. Make sure the D-Tube slides inside the valve.
Transformer
Grease
Packet
Grid Legs (3 for
Round and 4 for
Square)
Grid (Round or Square)
Unscrew Spill Cap
D-Tube
Brine Well/
Safety Float
Brine Tank Lid
Attach
Upper
Basket
CAUTION: Make sure the power cord of the
valve doesnt get caught between the threads

Step 3 – Assembling Brine Tank
a. Attach the three brine grid legs to grid plate. The legs will snap on to the tabs of
the salt plate making a “click” sound. For square brine tank there are four legs.
b. Insert the brine well assembly inside the grid plate as well below.
c. Drop the brine grid with brine well inside the brine tank such that the nut fitting
faces the hole on the brine tank. Then press the grid evenly inside the brine tank
until the brine grid legs touches the bottom of the brine tank.
d. Take the brine tube and insert the nut and plastic sleeve as shown below.
Insert Sleeve
e. Insert the tube in the float assembly elbow and hand tighten the nut. In many
cases the brine line already come installed from the factory. Leave the other end
of the brine line tube inside the brine tank
f. For installation of brine tank at the installation site, pull the other end of the
brine tube from the hole on the brine tank. The completed assembly is
shown below.
IMPORTANT: IN
ROUND BRINE TANK,
IT IS IMPORTANT TO
ALIGN THE HANDLE TO
THE BRINE WELL AS
SHOWN
The hole in the brine tank
should line up with the brine
line as shown for round and
square brine tank.
Step 5 – Power and Program Valve
Key Pad Conguration
SETTINGS This function is to enter the basic set up information required at the
time of installation.
MANUAL This function is to initiate an immediate or delayed manual
REGEN regeneration.
DOWN / Increase or decrease the value of the settings while in the
UP programming mode.
6(77,1*60$18$/
5(*(1
83
2:1
Hole
Settings
Press SETTINGS key
(3 SECONDS / BEEP)
TIME OF DAY
12:01 PM
Press SETTINGS key
Press SETTINGS key
MONTH
AUGUST
Press SETTINGS key
Press SETTINGS key
YEAR
2016
DAY
Step 4 – Attaching Brine Tubing to the Valve
Put insert
inside the
brine tubing
SALT SETTING
Press SETTINGS key
SET HARDNESS
20 GRAINS
Press SETTINGS key
SET PEOPLE
4
Press SETTINGS key
SALT SETTING
HIGH EFFICIENCY
STANDARD
IRON & MN
21
Press SETTINGS key
Press SETTINGS key
WATER TYPE
MUNICIPAL
WELL / OTHER
Press SETTINGS key
REGEN TIME
2:00 AM
Press SETTINGS key
PROGRAMMING
COMPLETE
Choose HIGH EFFICIENCY to minimize salt usage. Your system will regenerate
a little more often but your salt usage can be reduced by 20% compared to
the STANDARD setting. Choose STANDARD when you need to maximize your
capacity but still operate the system with good efficiency. Choose IRON & MN
if you have problem water containing these minerals. The high salt setting
will be needed since these minerals are more difficult to clean out of the
resin bed. Note: A resin cleaner will also need to periodically added to the
brine tank to insure proper operation.
WATER TYPE
This setting will determine if the BACKWASH OVERIDE function will be on
or off. Select MUNICIPAL if the water source is clean (<1NTU turbidity) and
the system will skip the back wash cycle based on the setting in BACKWASH
OVERIDE. Select WELL / OTHER if any Iron or Manganese is present or if the
water source is not clean (< 1NTU turbidity). The system will back wash
every time.
his setting determines the time of day to perform a scheduled regeneration.
TOLL-FREE: 1-877-288-9888
Regina, SK • Cambridge, ON • Carmel, IN • Fridley, MN • Phoenix, AZ
www.hydrotechwater.com
Follow the Instruction Manual to Complete
the Installation of the Product
55227 05/16