Step 1 – Inspection
Check to make sure you got everything supplied by factory and there is no visible or concealed damage. In case of missing items, please contact customer service immediately
and have the Product Serial # handy. (Product Serial # can be found at the back of the control valve, see below)
,WHP
<0/
'HVF
6HULDO
<0/
')
The items you will expect are:
1. Tank with Carbon Media loaded
2. Control Valve
3. Parts Kit
Product Serial #
3. Parts Kit
3/4” Elbow
Fitting X 2
1. Tank with Carbon
Media loaded
Spill Cap
D-Tube
Bypass Tool
Set of Injectors
2. Control Valve
Brine
Elbow
Drain Clip
Drain Hose Fitting
Bypass Test Port Clip X 2
Bypass
Bypass
Cllips X 2
1” Straight
Fitting X 2
Upper Basket/
Strainer
Grease port Orings using brush (not included) or
your finger (Make sure to wear protective gloves)
Step 2 – Installing Valve to the Tank
Select a Installation location and make sure there
is access to 110V power outlet and drain line. Lube
the bottom Valve Orings with the grease supplied,
Attach the Upper Basket. Unscrew the spill cap.
Carefully Slide the D-Tube inside the Valve and
Screw the Valve inside the Tank such that the power
cord doesnt get caught between the valve and the
tank. Make sure the D-Tube slides inside the valve.
Brine line Plug ((used for Filters))
Set of
Washers
Unscrew Spill Cap
Transformer
Grease
Packet
D-Tube
Attach
Upper
Basket
CAUTION: Make sure the power cord of the
valve doesnt get caught between the threads

Step 3 – Attaching Brine Port Plug
Push the Plug inside
the Brine Elbow here
Step 4 – Change Drain Line Flow Washer
1. Remove the red clip as shown
2. Pull the drain elbow
3. Remove and Replace the washer as shown.
For 1 CF - use #5 (3.5 GPM)
For 1.5 CF - use #6 (4.0 GPM)
1.
2. 3.
Step 5 – Power the Valve and Master Program to Filter Conguration
Attach the Transformer cable to the valve and plug in the transformer to the 110V Power outlet. you will notice the two screens on right will alternate.
CALENDAR
CLOCK
TIME
08:27 AM
6(77,1*6 83
1. Hold UP and DOWN button for 5 seconds and Adjust Valve Type to “CALENDAR CLOCK”. PRESS SELECT
2. Adjust Regeneration Time. Press UP and DOWN key to quickly advance the hour and minuted. When desired time is displayed, press SELECT to Backwash
3. Adjust Backwash Time to 10 Minutes. UP and DOWN key to quickly change the minutes. When desired minutes press SELECT to Brine
4. Adjust Brine Time to 1 Minute. Press UP and DOWN key to quickly change the minutes. When desired minutes press SELECT to Rinse
'2:16(/(&7
5. Adjust Rinse Time to 10 Minutes. Press UP and DOWN key to quickly change the minutes. When desired minutes press SELECT to Refill
6. Adjust Refill Time to 0.0 Minutes. Press UP and DOWN key to quickly change the minutes. When desired minutes press SELECT to complete the programming
KEYPAD
TIME
08:27 AM
REMAIN
GAL 1060
BACKWASH
10 MIN
BRINE
01 MIN
RINSE
10 MIN
REG TIME
02:00 AM
REFILL
0.0 MIN
Step 6 – Program the Valve
1. Press SETTINGS key to advance to TIME OF DAY. TIME OF DAY will flash.
2. Press the UP or DOWN key to adjust the TIME OF DAY. Press & hold the UP or DOWN key to quickly advance the hour and minutes. When desired time is displayed press SELECT to advance to the
REGEN DAYS setting. REGEN DAYS will flash.
REG. DAYS
03
3. Press SELECT to complete pro-gramming. Now you will notice that two screens below will alternate. Time and Reg Days
TIME
08:27 AM
TIME
08:27 AM
REMAIN
DAYS 03
TOLL-FREE: 1-877-288-9888
Regina, SK • Cambridge, ON • Carmel, IN • Fridley, MN • Phoenix, AZ
www.hydrotechwater.com
Follow the Instruction Manual to Complete
the Installation of the Product
55119 05/16