Step 1 – Inspection
Check to make sure you got everything supplied by factory and there is no visible or concealed damage. In case of missing items, please contact customer service immediately and have the Product Serial # handy. (Product Serial # can be found at the back of the control valve, see below)
,WHP
<0/
'HVF
6HULDO
<0/
')
The items you will expect are:
1. Tank with Carbon Media loaded
2. Control Valve
3. Parts Kit
Product Serial #
3. Parts Kit
3/4” Elbow Fitting X 2
1. Tank with Carbon
Media loaded
Spill Cap
D-Tube
Bypass Tool
Set of Injectors
2. Control Valve
Brine Elbow
Drain Hose Fitting
Bypass Test Port Clip X 2
Bypass
Bypass Cllips X 2
1” Straight Fitting X 2
Upper Basket/ Strainer
Grease port Orings using brush (not included) or your finger (Make sure to wear protective gloves)
Step 2 – Installing Valve to the Tank
Select a Installation location and make sure there is access to 110V power outlet and drain line. Lube the bottom Valve Orings with the grease supplied, Attach the Upper Basket. Unscrew the spill cap. Carefully Slide the D-Tube inside the Valve and Screw the Valve inside the Tank such that the power cord doesnt get caught between the valve and the tank. Make sure the D-Tube slides inside the valve.
Brine line Plug ((used for Filters))
Set of Washers
Unscrew Spill Cap
Transformer
Grease Packet
D-Tube
Attach Upper Basket
CAUTION: Make sure the power cord of the valve doesnt get caught between the threads
Page 2
Step 3 – Attaching Brine Port Plug
Push the Plug inside the Brine Elbow here
Step 4 – Change Drain Line Flow Washer
1. Remove the red clip as shown
2. Pull the drain elbow
3. Remove and Replace the washer as shown.
For 1 CF - use #5 (3.5 GPM) For 1.5 CF - use #6 (4.0 GPM)
1.
2. 3.
Step 5 – Power the Valve and Master Program to Filter Conguration
Attach the Transformer cable to the valve and plug in the transformer to the 110V Power outlet. you will notice the two screens on right will alternate.
CALENDAR CLOCK
TIME 08:27 AM
6(77,1*6 83
1. Hold UP and DOWN button for 5 seconds and Adjust Valve Type to “CALENDAR CLOCK”. PRESS SELECT
2. Adjust Regeneration Time. Press UP and DOWN key to quickly advance the hour and minuted. When desired time is displayed, press SELECT to Backwash
3. Adjust Backwash Time to 10 Minutes. UP and DOWN key to quickly change the minutes. When desired minutes press SELECT to Brine
4. Adjust Brine Time to 1 Minute. Press UP and DOWN key to quickly change the minutes. When desired minutes press SELECT to Rinse
'2:16(/(&7
5. Adjust Rinse Time to 10 Minutes. Press UP and DOWN key to quickly change the minutes. When desired minutes press SELECT to Refill
6. Adjust Refill Time to 0.0 Minutes. Press UP and DOWN key to quickly change the minutes. When desired minutes press SELECT to complete the programming
KEYPAD
TIME 08:27 AM
REMAIN GAL 1060
BACKWASH 10 MIN
BRINE 01 MIN
RINSE 10 MIN
REG TIME 02:00 AM
REFILL
0.0 MIN
Step 6 – Program the Valve
1. Press SETTINGS key to advance to TIME OF DAY. TIME OF DAY will flash.
2. Press the UP or DOWN key to adjust the TIME OF DAY. Press & hold the UP or DOWN key to quickly advance the hour and minutes. When desired time is displayed press SELECT to advance to the
REGEN DAYS setting. REGEN DAYS will flash.
REG. DAYS 03
3. Press SELECT to complete pro-gramming. Now you will notice that two screens below will alternate. Time and Reg Days
TIME 08:27 AM
TIME 08:27 AM
REMAIN DAYS 03
TOLL-FREE: 1-877-288-9888
Regina, SK • Cambridge, ON • Carmel, IN • Fridley, MN • Phoenix, AZ
www.hydrotechwater.com
Follow the Instruction Manual to Complete the Installation of the Product