Hydro systems EvoRinse Installation And Operation Manual

EvoRinse
Installation and Operation Manual
HYD90098598 Rev A
Contents
1 Specification
Description Product Features Specification Intended Use Product Diagram Kit Contents
2 Installation
Site Survey & Installation Requirements Installation Diagram Mechanical Installation
Wall mounting Rinse discharge hose connection Rinse aid tube connection (product option) Water connection
Electrical Installation
Electrical connections Mains power wiring
3 Troubleshooting
Dead Unit
4 Maintenance
Maintenance Every Maintenance Visit Spray Nozzle Replacement
5 Spare Parts
6 Decommissioning & Disposal
7 Safety
8 EC Declaration of Conformity
9 WEEE
2
1. Specifications
1.1 Description
The EvoRinse is a rinse powder / solid rinse aid dissolver for use with EvoWash warewash machines.
1.2
Product Features
Bottle lockout feature to prevent non-approved chemicals being used in the product.
1.3 Specification
Product Dimensions (unboxed)
Size 254mm (W) x 366mm (L) x 234mm (D)
Weight 2.3 Kg
Product Dimensions (boxed)
Size 370mm (W) x 425mm (L) x 305mm (D)
Weight 3.4 Kg
Electrical
Input voltage / Frequency / Current 100 to 240 VAC / 50/60 Hz. / 1.5 A (Max.) Power 12W (Max) Electrical Class Class II
Installation Environment
Temperature 10°C to 50°C (max.) Humidity 95% relative humidity (max.) Indoor Installation Indoor use only. Must not be installed outdoors
Performance
Detergent dissolution rate Min-max
Water Inlet Connection
Water temperature 5°C to 60°C (max.) Pressure 0.2MPa (2 bar) - 0.6MPa (6 bar) Inbuilt backflow prevention - EN1717 DB - Category 4 chemicals
1.4 Intended Use
• The EvoRinse is intended for use in industrial applications and is not suitable for domestic use.
• The product must only be used for rinsing in dish and warewash applications. The manufacturer waives any responsibility arisen from incorrect usage or transportation.
3
x 4
x 4
x 4
2
x 2
1.5 Product Diagram
1
2
KEY:
1. Switch Lever
2. Keyway (optional)
3. Fixing Points (x4)
4. Water Inlet
5. Water Filter
6. Mesh Screen
7. Water Spray Nozzle
7
6
5
4
3
1.6 Kit Contents
4
2. Installation
CAUTION Before an installation takes place it is
advisable to complete a site survey to ensure the EvoRinse can be installed in a position that meets all the requirements below.
CAUTION Do not install unit in an ATEX environment
WARNING Electrical installation should be completed
by a qualified electrician. All local and national electrical regulations are to be observed.
2.1 Site Survey & Installation Requirements
• Unit is to be installed by a trained technician; all local and national water regulations are to be observed.
• Unit must be installed indoors, in an area that does not suffer excess temperature changes, direct sunlight, frost or precipitation of any kind.
• The area must be free of high levels of EMC disturbance.
• Ensue the unit is mounted in an accessible location, above the height of the dishwasher detergent and rinse inlet connections.
• Installer to ensure the suitability of the wall or mounting substrate, which should be flat and perpendicular to the floor.
• Unit location should be well lit for any maintenance, and should be free of high levels of dust particulates.
• Scheduled maintenance should be carried out on the unit at least once per year.
• It is a legal requirement that all water supply hose sets must be compliant with IEC 61770.
• Ensure that the chemicals being used are compatible with the tubing supplied. If you are unsure, please contact your local distributor.
5