Hydrel Paradox, Paradox PDX7 Installation Instructions Manual

PARADOX SERIES
PDX7
INSTALLATION INSTRUCTIONS
TO INSTALL:
1. Dig a hole to appropriate depth allowing for rough-in-section to
be secured to conduit.
Door Screws
Flush Pour Shield
Temporary Cover Plate
Rough-in-Section (RIS)
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
2. To install with door flush to finish grade:
2a. Mount Rough-in-Section
(RIS) with flush pour shield placed at finish grade.
Flush Pour Shield
Temporary Cover Plate
Rough-in­Section (RIS)
©2007 Acuity Brands Lighting, Inc. Rev. 11/28/07 INS-PDX7_REV0
Pour Screw
Finish Grade
Enlarged detail with temporary cover plate and flush pour shield.
Rough-in-Section (RIS) before
pouring finish grade
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
Door
Finish Grade
Rough-in-Section (RIS) after
pouring finish grade
Finish Grade
Enlarged detail with door installed.
Rough-in­Section (RIS)
12881 Bradley Ave
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548
PARADOX SERIES
PDX7
INSTALLATION INSTRUCTIONS
Door Screws
Flush Pour Shield
Temporary Cover Plate
Rough-in-Section (RIS)
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
3. To install with Rough-in-Section (RIS) flush to finish grade:
3a. Remove flush pour shield
from Rough-in-Section (RIS).
3b.Re-attach temporary cover
plate onto Rough-in-Section (RIS).
3c. Mount Rough-in-Section
with temporary cover plate placed at finish grade.
Rough-in­Section (RIS)
Temporary Cover Plate
Rough-in-Section (RIS) before
pouring finish grade.
Door Screw
Finish Grade
Enlarged detail with temporary cover plate.
Finish
Door
Finish Grade
Rough-in-Section (RIS) after
pouring finish grade.
Grade
1/8”1/8”
1/8”
1/8”1/8”
Enlarged detail with door installed.
Rough-in­Section (RIS)
©2007 Acuity Brands Lighting, Inc. Rev. 11/28/07 INS-PDX7_REV0
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
12881 Bradley Ave
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548
INSTALLATION INSTRUCTIONS
4. For optional rebar anchoring: Secure rebar as shown (rebar by others).
FINISH GRADE
Install fixture flush per step 2 / 3.
PARADOX SERIES
PDX7
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
Secure rough-in section to rebar to prevent “floating.”
Install suitable thread sealing compound when connecting conduit (side or bottom entry).
CONDUIT
CONDUIT
REBAR
CAUTION: When installing in organic mulch, surround rough-in section with approximately six inches (15cm) of sand or other non-organic substance.
©2007 Acuity Brands Lighting, Inc. Rev. 11/28/07 INS-PDX7_REV0
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
12881 Bradley Ave
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548
INSTALLATION INSTRUCTIONS
5. Remove temporary cover or tempo-
6. Loosen junction box screw and re-
PARADOX SERIES
PDX7
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
rary cover and flush pour shield.
move lid.
IMPORTANT NOTE:
NOT lose screw. Screw contains an O-ring seal. It
MUST be used to rein-
stall junction box lid in Step 9.
7. Connect 3/4” NPT conduit to junction box
(side or bottom entry). Seal conduit entry using suitable thread sealing compound to ensure conduit is watertight and to prevent moisture penetration from con­duit system.
8. Pull electrical supply conductors and make wire splice in accordance with
Do
NEC.
9. Reinstall junction box lid with O-ring screw provided.
CAUTION: DO NOT OVER TIGHTEN (20 IN-LBS OR 2 n-M).
©2007 Acuity Brands Lighting, Inc. Rev. 11/28/07 INS-PDX7_REV0
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
12881 Bradley Ave
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548
INSTALLATION INSTRUCTIONS
electrician in accordance with the National Electrical Code
10. Insert power supply module (HID Bal­last, Fluorescent Ballast, LED Power Supply, Low Voltage Transformer) into housing. Connect using Hydrel pro­vided quick connector to pre-installed housing wiring.
PARADOX SERIES
PDX7
Installation should be performed by a qualified
and relevant local codes.
11. Install lamp module. Connect to modular power supply using Hydrel provided quick connector.
©2007 Acuity Brands Lighting, Inc. Rev. 11/28/07 INS-PDX7_REV0
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
12881 Bradley Ave
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548
INSTALLATION INSTRUCTIONS
12. Adjust lamp/reflector assembly to aim. Secure with locking/aiming screws.
13. Install door lens assembly ensuring screws are tight.
PARADOX SERIES
PDX7
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
LAMP ADJUSTMENT DETAIL
1. Loosen two tilt screws.
4. Lock rotational ring screw.
2. Tilt lamp.
3. Tighten two
tilt screws.
©2007 Acuity Brands Lighting, Inc. Rev. 11/28/07 INS-PDX7_REV0
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
12881 Bradley Ave
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548