Hydor HV800, HV2000, HV1000, HV1250A, HV1500 Installation And Maintenance Instructions Manual

...
HV Inst Issue 2: 18.06.15
Installation and Maintenance Instructions.
THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.
Owner / installer: The life of this apparatus and its eciency will be increased if
its use and maintenance is carried out in accordance with these instructions and current statutory requirements. The installation and initial adjustments should be carried out by a qualified and competent technician. Hydor Limited should be consulted before substituting or fitting parts from another manufacturer. It is the responsibility of the installer to verify that the installation is in accordance with the following standards and the owner is given the current User’s Manual.
Any modifications to the fan or its installation, even the smallest modification, change or elimination of security components or pieces that influence the eciency or loss of ventilation, will result in the CE Certification and Hydor’s warranty being cancelled.
Single Phase
Model
Speed
r/min
Supply
V-Ph-Hz
PowerkwFLC
Amps
Start
Amps
Blade Mattl.
Weight
kg
Weight kg incl.
Louvre
HV800 530 230-1-50 0750 4.5 14.3 st.st 31 44
HV1000 600 230-1-50 0750 5.4 14.9 st.st 40 50
HV1250 410 230-1-50 1,100 7.2 25.7 st.st 50 70
HV1250A 425 230-1-50 1,100 7.5 25.7 ali. 50 70
HV1250 425 230-1-50 1,500 8.4 29.5 st.st 52 72
HV1500 360 230-1-50 1,500 9.4 33.0 st.st 55 85
HV2000 375 230-1-50 1,500 10.0 35.0 st.st 75 100
HV Belt Drive Fan
incorrect
correct, minimum height 5mm
HV Inst Issue 2: 18.06.15HV Inst Issue 2: 18.06.15
Three Phase
Model
Speed
r/min
Supply
V-Ph-Hz
Power
Watts
FLC
Amps
Start
Amps
Blade Mattl.
Weight
Kg
Weight Kg incl. Louvre
HV800 530 400-3-50 0750 2.0 5.9 st.st 32 44
HV1000 600 400-3-50 0750 2.6 7. 8 st.st 40 50
HV1250 410 400-3-50 1,100 2.89 8.7 st.st 50 70
HV1250A 425 400-3-50 1,100 2.89 8.7 ali. 50 70
HV1250 425 400-3-50 1,500 3.2 9.6 st.st 52 72
HV1500 360 400-3-50 1,500 3.6 10.8 st.st 55 85
HV2000 375 400-3-50 1,500 3.8 12.5 st.st 75 100
1. Description
1.1 It is important these Installation and Maintenance Instructions are fully adhered to.
1.2 Full details of the unit supplied are shown on the product nameplate. If in doubt about any detail contact Hydor or its agents for clarification.
1.3 All electrical installations must be carried out by suitably qualified and competent personnel in accordance with all current statutory requirements.
1.4 These instructions cover only the Hydor product and do not include the supply or installation of any safety equipment that may be required e.g. proper electrical isolation.
1.5 Any declarations made by Hydor about product installation and safety, are dependent on the fan unit being used within installations which themselves meet the requirements of the relevant Standards and Directives of your region.
1.6 The fan unit is designed for use in an ambient temperature of up to 50°C and 95% relative humidity. The fan unit is not suitable for corrosive or explosive atmospheres.
1.7 The installer should provide easy access to the fan to facilitate future maintenance.
1.8 The installer should ensure the fan unit is mounted slightly tilted forward at the top towards the outside of the building and adequately supported. Holes are provided in the base of the casing to assist drainage.
1.9 This product is not intended for the use of young children or infirm persons unless they have been dequately supervised by a responsible person to ensure that they can use the product safely. Young children should be supervised to ensure that they do not play with the appliance.
WARNING The fan unit must be isolated from the power supply during
installation and maintenance. The fan must be earthed in accordance with the local regulations.
2. Installation
2.1 Upon receipt, the fan unit should be visually inspected to check for any damage. Ensure that the impeller is free to rotate.
2.2 If there are any queries concerning the fan unit, HYDOR should be contacted prior to installation. air space, in front and behind the fan. A minimum of 2 metres is required.
2.3 If the unit is to be suspended, attach a chain to each eyebolt using separate D shackles for each chain. Form a “V ” using two chains [one pair in front and one pair rear] and two small D shackles attached to one large D shackle each. In some instances it will be beneficial to suspend the fan leaning forward by adjusting the chains to direct the air downwards.
NOTE Chain and D-shackles are not provided. Ensure that chain used
will support weight of unit. Additionally, in some instances using long chains may cause a pendulum eect to develop; an additional check chain or rope will prevent this.
2.4 Where a fan is installed in a wall of the building, ensure that the access to the terminal plate and panel is available. Secure the fan unit using angled steel to fix to a surrounding wall.
NOTE Ensure the unit is installed square; failure to do so may result in
poor operation of the back-draught shutter blades.
2.5 Check the details on the motor rating plate to ensure that the correct power supply (voltage, frequency).
2.6 Eyebolts are provided as extras; for units which are to be suspended.
2.7 Refer to the appropriate wiring diagram. Means for electrical disconnection must be incorporated in the wiring installation in accordance with the relevant wiring and electrical regulations. Ensure that all earth connections are made and secure. Fuses/circuit breakers are used to provide short circuit protection only. A starter panel with overload protection must be fitted to protect the motor.
2.8 If the fan is being used through a speed control device, either electrically or electronically, refer to the relevant control device instructions before commencing installation.
Loading...
+ 3 hidden pages