Hyco IN60T, IN44T Installation Instructions

Product Instruction Manual
Rho
IN44T & IN60T
Instantaneous inline water heater
Version 3.2 Jan 2015
V15.6/3
2
1. Important safety points
The appliance must only be connected to a single phase supply.
Isolate electrical and water supply before installation.
Electrical installation must be carried out by a qualified electrician in accordance with the latest edition of the IEE wiring regulations.
Only connect the appliance to a power supply that conforms to the specification stated on rating plate.
The appliance must be earthed at all times.
The appliance must be permanently connected to the electrical supply through an isolating switch with a contact separation of no less than 3mm in all poles.
Do not use the appliance if there is any possibility of the water supply being frozen.
Never remove the cover of the appliance without first isolating it from the electrical power supply.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use a supply with incoming water temperatures greater than 600C.
3
2. Installation
Wall Mounting
Do not install if there is a risk of water freezing in the heater.
Do not install the heater where the consequences of a leak could be unusually severe. (e.g. above computer equipment).
When choosing a location for the heater, consider the visibility of any leak that might arise. This is particularly important when locating in a concealed area such as a cupboard.
The heater must be mounted horizontally with the inlet and outlet connections
at the top of the heater.
Before attaching the heater to the wall, consider the wiring route to the heater.
It is advised that the heater be located as close as practical to the hot water outlet in order to avoid unnecessary heat losses through the pipework.