Warning3
General Information4
Entyce Hot Cold Lifting Instructions5
Close-Off Removal7
TY3 4X4E-S Cold Section8
Installation10
Electrical11
Wiring Diagram Index11
Wiring Diagram12
Controller Programmed Parameters14
TY Cold Maintenance16
Service Tips18
Controller Manual19
TY 4X5E-H Hot Section43
Start up44
Standard Hot Case Settings46
Operation47
Electrical48
Wiring Diagram Index48
Wiring Diagram49
Cleaning and Maintenance53
TY Hot Maintenance56
2
Warning
3
General Information
Case Descrip on:
This Booklet specifi cally covers the
Following models:
EntyceTY3
TY4
Descrip on: The ENTYCE-HOT/COLD model series are Mul -deck island merchandisers designed for medium
temperature applica ons such as: Deli/Dairy/Beverage. The case is a combina on of a remote type models,
which require separate condensing unit connec ons as well as a self-contained model. Each self-contained
model will have it’s own condensing unit, factory installed beneath the display area of the case ready for
opera on when electrical service is connected.
Shipping Damage: All equipment should be thoroughly examined for shipping damage before and during
unloading. This equipment has been carefully inspected at our factory and the carrier has assumed
responsibility for safe arrival. If damaged, either apparent or concealed, claim must be made to the carrier.
Apparent Loss or Damage: If there is an obvious loss or damage, it must be noted on the freight bill or express
receipt and signed by the carrier’s agent; otherwise, carrier may refuse claim. The carrier will supply necessary
claim forms.
Concealed Loss or Damage: When loss or damage is not apparent un l a er all equipment is uncrated, a claim
for concealed damage is made. Make request in wri ng to carrier for inspec on within 15 days, and retain all
packaging. The carrier will supply inspec on report and required claim forms.
Loca on/Store Condi ons: The refrigerated merchandisers have been designed for use only in air condi oned
stores where temperature and humidity are maintained either75°F ambient and 55% RH. DO NOT allow
air condi oning, electric fans, ovens, open doors or windows (etc.) to create air currents around the
merchandiser, as this will impair its correct opera on.
Shortages: Check your shipment for any possible shortages of material. If a shortage should exist and is found
to be the responsibility of Hussmann Chino, no fy Hussmann Chino. If such a shortage involves the carrier,
no fy the carrier immediately, and request an inspec on. Hussmann Chino will acknowledge shortages within
ten days from receipt of equipment.
Hussmann Chino Product Control: The serial number and shipping date of all equipment has been recorded
in Hussmann’s fi les for warranty and replacement part purposes. All correspondence pertaining to warranty
or parts ordering must include the serial number of each piece of equipment involved, in order to provide the
customer with the correct parts.
Keep this booklet with the case at all times for future reference.
/CHINO
A publication of HUSSMANN®Chino
13770 Ramona Avenue • Chino, California 91710
(909) 628-8942 FAX
(909) 590-4910
(800) 395-9229
4
Entyce Hot Cold Lifting Instructions
5
Installation
J-Bar lift points typical for Cold
and Hot section of case.
6
Close-Off Removal
Close-off removal for Entyce case Typical
Step 1
Slide bottom of close-off in upward motion to
remove from tabs.
Step 2
Pull Close-off in outward then downward motion
to completely remove side panel close-off
Cold Case Condensate Access Vent.
Self Contained case has 2 vented panels on
each side of the case for proper circulation
through condensing unit area.
See illustrations below for access to panels.
Step 3
Once side panel close-off has been removed
from case four screws will be visible which fasten
the round close-off to the case. Remove the
four screws 2 on each end to remove the end
close-off.
Hot Case Heating Control Panels
Hot case section has an access panels on the
side of the case for access to heating controls for
shelves and overhead heating.
See illustrations below for access to panel.
7
TY3 4X4E-S Cold Section
8
Cold Sec on Start up
1. Apply power to the merchandiser.
2. Wait for the self check to complete.
•During the self check, each LED fl ashes for one second, then
all LEDs turn on for two seconds.
•If the LEDs do not fl ash, make sure the adjustment knob is
not in the Off posi on.
3. The compressor will start for 30 seconds a er the self check
is complete.
•The merchandiser temperature displays at startup
•An ini al defrost occurs two hours a er startup
•The compressor runs un l it reaches its setpoint tempera-
ture un l defrost.
4. Refrigera on: The compressor will con nue to cycle on-and-
off normal un l defrost occurs.
5. Defrost: Defrost is scheduled to occur every 8 hours, or ear-
lier if triggered by a demand defrost.
•Defrost con nues for a set me period, or un l the defrost
termina on temperature is reached.
•During defrost the display shows the ini al defrost tem-
perature (temperature at start of defrost)
•This ini al defrost temperature is displayed for the set me
period (even if refrigera on mode resumes before the end
of this period).
6. If power is interrupted, the process will start over at step 1.
Opera on
1. DO NOT LOAD PRODUCT un l case reaches desired opera ng
temperature (approx. 4 hrs).
2. Food Product temperature must be below 38°F when loading
a case. Case is not designed to chill food.
3. Check shelf loading. Overstock will reduce case performance
and opera on.
4. DO NOT block discharge or return air. DO NOT display pack-
ages over the air inlet located at the front of the lowest deck.
This restricts airfl ow, and will result in warmer temperature in
the case.
5. DO NOT display more than 150 pounds of product per shelf.
Addi onal weight will damage the shelves.
Alarms and codes
See Controller Manual for details
Installa on Store Condi ons
•Case is designed to operate at temperatures 80°F and or
below 55% rela ve humidity. Case must be kept in that
environment to ensure case performance and product
safety.
Temperature Adjustment
See Controller Manual for details
For prompt service when contac ng the factory regarding
problems, be sure to have the Case Model and Serial Number
handy. This informa on is on a plate located on itself.
www.hussmann.com (909) 590-4910 (800) 395-9229
Installation
Store Conditions
Do Not Install the Vented Panels of the
self-contained model against a wall or
other storage fi xture.
Located in the lower front and rear of the self-contained
models are vented panels. These panels allow air circulation
to the condensing unit. Blocking or restricting air circulation
through these panels can cause poor performance and
damage the refrigeration system.
Exterior Loading
Thesemodelshavenot beenstructurallydesignedto support
excessive external loading. Do not walk on their tops;
This could cause serious personal injury and damage to
the fi xture.
Uncrating the Stand
Place the fixture as close to its permanent position as
possible. Remove the top of the crate. Detach the walls from
each other and remove from the skid. Unbolt the case from
the skid. The fi xture can now be lifted off the crate skid. Lift
only at base of stand!
Leveling
A LEVEL CASE IS NECESSARY TO INSURE PROPER
OPERATION AND WATER DRAINAGE.
Note: To avoid removing concrete fl ooring, begin lineup
leveling from the highest point of the store fl oor.
Condensate Pan Setup
There is one condensate evaporator pan on this unit. The drain pipe from the case feed into the condensate pan, once
water levels are high enough in the condensate pan the fl oat switch level is triggered which will then trigger the heater to
raise temperature therefore evaporating the water into the case airstream.
10
Electrical
CASE MUST BE GROUNDED
NOTE: Refer to label affi xed to case to determine the
actual confi guration as checked in the “TYPE
INSTALLED” boxes.
Field Wiring and Serial Plate Amperage
Field Wiring must be sized for component amperes printed
on the serial plate.Actual ampere draw may be less
than specifi ed. Field wiring from the refrigeration control
panel to the merchandisers is required for refrigeration
thermostats. Case amperes are listed on the wiring
diagram, but always check the serial plate.
Standard lighting forall refrigerated modelswillbefulllength
LED Lights located within the case at the top.
Wiring Diagram Index
ModelTierDescriptionSizeDiagram #
EntyceTY4TY4-4X4E-S4’3042639
11
Wiring Diagram
15A
12
ControllerProgrammedParameters
14
15
TY Cold Maintenance
Case Cleaning
To insure long life, proper sanitation and minimum
maintenance costs, the refrigerator should be thoroughly
cleaned frequently. SHUT OFF FAN BEFORE CLEANING:
It can be unplugged within the case, or shut off entire case
at the source. The interior bottom may be wiped with any
domestic soap or detergent based cleaners. Sanitizing
solutions will not harm the interior bottom,
WARNING! DO NOT USE WATER HOSES! A self
contained case empties into an evaporator pan that WILL
OVERFLOW IF TOO MUCH WATER IS INTRODUCED
during cleaning
Service
Tips and Troubleshooting
Before calling for service:
16
TY Cold Maintenance
Stainless Steel Cleaning and Care
There are three basic things, which can break down your
stainless steel’s passivity layer and allow corrosion.
Don’t Despair! Here are a few steps that can help prevent
stainless steel rust.
17
Service Tips
WARNING
ALWAYS DISCONNECT THE ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR
REPLACING ANY ELECTRICAL COMPONENT OF THIS REFRIGERATOR. THIS INCLUDES, BUT IS NOT
LIMITED TO SUCH ITEMS AS FANS AND THERMOSTATS.
Fan Blade Replacement
The evaporator fan is located directly under the deck pan.
Shouldthefanbladeever needservicing.ALWAYS REPLACE
THE FAN BLADE WITH THE RAISED EMBOSSING SIDE
OF THE BLADE INSTALLED TOWARD THE MOTOR.
Honeycomb Removal & Cleaning
CAUTION: DO NOT TEAR THE HONEYCOMB
1) Remove the honeycomb assembly as follows:
Insert asmall Phillipsscrewdriver behind therearedge ofthe
honeycomb on the right hand end and gently pull down. The
bottom of the honeycomb will drop down. Continuedown the
length of the case, lifting the honeycomb out.
2) To clean honeycomb:
Mix powdereddetergent, in warm water.(5 to 7 Tablespoons
per gallon)
Immerse or spot clean the honeycomb. Use care not to
damage the cell structure of the honeycomb.
Rinse thoroughly in clean water. Shake excess water from
the honeycomb and dry.(If heat isused, do not exceed 140°
F dry heat)
3) Install honeycomb by inserting the notched side up
against the defl ector and press upwards inserting the bottom
of the honeycomb into the back ledge. Slide along the
honeycomb, pressing the front edge upward into the ledge.
Becareful no todamage the cellsor cut yourselfon the edges
of the honeycomb.
Ballast/LED Driver Replacement
The power supply for the LED fi xtures is located under the
case in a dedicated electrical box.
For access to the ballast:
-
Stocking
Improper temperature and lighting will cause serious
product loss. Discoloration, dehydration and spoilage can be
controlled with proper use of the equipment and handling of
product. Product temperature should always be maintained
at a constant and proper temperature. This means that from
thetimethe product is received,through storage, preparation
anddisplay, thetemperatureof theproductmustbe controlled
to maximize life of the product. Hussmann cases were not
designed to “heat up” or “cool down” product - but rather to
maintain an item’s proper temperature for maximum shelf
life. To achieve the protection required always:
1. Minimize processing time to avoid damaging temperature rise to theproduct. Product should be at
proper temperature.
2. Keep the air in and around the case area free
of foreign gassesand fumes or food will rapidly
deteriorate.
3. Maintain the display merchandisers temperature
controls as outlined in the refrigerator section of
this manual.
4. Do not place anyproduct into these refrigerators
until all controls havebeen adjusted and they are
operating at the propertemperature.Allow merchandiser to operate a minimum of three (3) hours
before stocking with any product.
5. Whenstocking, never allow the product to extend
beyond the recommended load limit.Air dis-
charge and return air fl ue must be unobstructed at
all times to provide proper refrigeration.
6. Avoid the use of supplemental fl ood or spot light-
ing.Displaylightintensityhasbeendesignedfor
maximum visibility and product lifeat the factory.
-
-
18
Loading...