Hussmann SMGV Specifications

Page 1
T'Stat Bulb
Location
(Optional
Lights)
D
C
A
D
B
SMGV
P/N 0518276_A
NSF
®
Certified
October 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A. 0392457 Fan Motor, Evaporator (120V) (1)
(MO.4410101)
0420242 Fan Blade (120V) (FB.4780638)
embossing toward motor
B. 0137880 Optional Adjustable (2)
Refrigeration Thermostat ((CT)4481084)
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
C. Ballast, Electronic (3)
0355716 2 lamps (120V) (BA.0355716) 0355398 3 lamps (120V) (BA.4480188)
D. Fluorescent Lamp (4)
Replace with like fixtures
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
P/N_0518276_A
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Page 2
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length* 48 1/
4 (1226) 72
1
/
4 (1835) 96
3
/
8 (2448) 144
1
/
2 (3670)
Maximum O/S dimension of case back to front 44
5
/
8 (1134) 44
5
/
8 (1134) 44
5
/
8 (1134) 44
5
/
8 (1134)
(Note: Includes bumper)
Back of case to front of splashguard 33
3
/
8 (848) 33
3
/
8 (848) 33
3
/
8 (848) 33
3
/
8 (848)
Center of rear legs to center of front legs 25
5
/8 (651) 25 5/8 (651) 25 5/8 (651) 25 5/8 (651)
Each End and Partition adds 1 1/2 in. (38 mm) to the length of the lineup.
Electrical Service
(B) RH end of case to Electrical raceway right edge 7 (178) 7 (178) 7 (178) 7 (178) (C) RH end of case to Electrical raceway left edge 41 3/
8 (1051) 32
3
/
4 (831) 44
1
/
2 (1131) 44
1
/
2 (1131)
Back of case to center of knockout 3
5
/8 (92) 3 5/8 (92) 3 5/8 (92) 3 5/8 (92)
* Electrical Field Wiring Connection Point
Waste Outlet
(D) RH end of case to the center of waste outlet 24 (610) 24 (610) 24 (610) 72
1
/4 (1835)
Back of case to center of waste outlet 25 5/
8 (652) 25
5
/
8 (652) 25
5
/
8 (652) 25
5
/
8 (652)
Water Seal
Center of tee to center of waste outlet 11
3
/8 (289) 11 3/8 (289) 11 3/8 (289) 11 3/8 (289)
Outside diameter of drip piping 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
** Field installed water seal outlets, tees, and connectors are shipped with the merchandiser.
Refrigeration Outlet
Back of case to center of refrigeration outlet 28 3/4 (731) 28 3/4 (731) 28 3/4 (731) 28 3/4 (731)
(E) RH end of case to center of refrigeration outlet 9 3/8 (238) 9 3/8 (238) 9 3/8 (238) 9 3/8 (238)
Outside diameter of the liquid line
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
Outside diameter of the suction line
5
/
8 (16)
5
/
8 (16)
5
/
8 (16)
5
/
8 (16)
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
SMGV Technical Data Sheet2 of 7
Engineering
Plan Views
C
L
(See Note*)
25
5
/
8
(651)
25
5
/
8
(651)
Legs
28
3
/
4
(730)
Front
Refrigeration Outlet
Water Seal
Waste Outlet
Leg Center Lines
Electrical
44
5
/
8
(1133)
33
3
/
8
(849)
(See Note**)
SMBV SMGV SSGV
A
B
D
C
E
Meat & Delicatessen
Multi-Pane Flat Glass
Models
Dimensions shown as in. and (mm).
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H. Schedule defrost at night while lights are off.
SMGV
Discharge Air (°F) 25
Evaporator (°F) 20
Unit Sizing (°F) 18
Btu/hr/ft SMGV
Parallel
210
Conventional
220
DEFROST DATA
SMGV
Frequency (hr) 24
Defrost Water (lb/ft/day) 0.10
(± 15% based on case configuration and
product loading).
SMGV
O
FFTIME (minutes) 70
Failsafe (minutes) 90
E
LECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
SMGV
CI/CO (Temp °F)* 13°F / 3°F
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)**
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Estimated Charge (lb)**
4 ft 0.75 lb 12 0z 0.35 kg
6 ft 1.0 lb 16 0z 0.5 kg
8 ft 1.5 lb 24 0z 0.7 kg
12 ft 2.0 lb 32 oz 0.9 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg).
Length Added to Lineup by:
Each Plastic End w/ Bumper (in.) 3
1
/2
Each End/Partition (in.) 1
1
/2
3 of 7P/N 0518276_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
10
(254)
SMGV
33
1
/2
(851)
25
5/8 (651)
28
3
/
4
(730)
34
(864)
20
(508)
25
1
/2
(648)
13
3
/4
(349)
33
3
/
8
(849)
44
5
/
8
(1133)
3
5
/8
(92)
FAN
11
3
/8
(289)
24
1
/2
(622)
Refrig.
Outlet
Elec.
25
O
52
(1321)
25
3
/4
(654)
C O
I
L
18
1
/2
(470)
24
(607)
Dimensions shown as in. and (mm).
Excel SMGV
Meat & Delicatessen
Multi-Pane Flat Glass, Gravity /w Blower Assist, 3 Display Level
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
SMGV Technical Data Sheet4 of 7
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Excel SMGV
Meat & Delicatessen
Electrical Data
Number of Fans 4 ft 6 ft 8 ft 12 ft Refrigeration (120V 60hz) – 4W 1 2 2 3
Export NA NA NA NA
Amperes Watts Merchandiser 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft Refrigeration Fans
Standard (120V 60hz) 0.31 0.62 0.62 0.93 24 48 48 72 Energy Efficient (120V 60hz) NA NA NA NA NA NA NA NA Export (230V 50 hz) NA NA NA NA NA NA NA NA
Ambient Air Wipe Fans NA NA NA NA NA NA NA NA
Constant On Anti-sweat Heaters NA NA NA NA NA NA NA NA
Cycling Anti-sweat Heaters NA NA NA NA NA NA NA NA
Minimum Circuit Ampacity
With Standard Fans (120V 60hz)
0.77 1.34 1.34 1.91
With Energy Efficient Fans
(120V 60hz)
NA NA NA NA
With Export Fans (230V 50 hz)
NA NA NA NA
Maximum Over Circuit Protection 120V 20 20 20 20
Electric Defrost Heaters (208V) NA NA NA NA NA NA NA NA Gas Defrost Heaters (208V) NA NA NA NA NA NA NA NA
Standard Lighting*
(120V 60hz) 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
2 Row Canopy 0.49 0.80 0.98 1.42 58 92 116 170
Optional Lighting
Third Row of Canopy 0.49 0.40 0.49 0.71 58 46 58 85 1 Row Ledge 0.49 0.40 0.49 0.71 58 46 58 85 2 Row Shelves 0.49 0.80 0.98 1.42 58 92 116 170
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52do
Page 5
5 of 7P/N 0518276_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
5
Glass /
Case Solid End Plastic End
4 ft 6 ft 8 ft 12 ft (each) (each)
lb (kg) 700 (318) 800 (363) 900 (408) 1300 (590) 70 (32) 100 (45)
5
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 2.86 ft3 /ft (0.27 m3 /m)
ARI Total Display Area
2
(Sq Ft/Ft) 2.15 ft2/ft (0.65 m2 /m)
Shelf Area 3(Sq Ft/Ft) 3.63 ft2/ft (1.10S m2 /m)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is one 7-inch shelf and one 10-inch shelf.
Excel SMGV
Meat & Delicatessen
Page 6
SMGV Technical Data Sheet6 of 7
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Fan Wiring
Offtime Defrost
= 120V POWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Refrigeration
Thermostat
To Condensing Unit
}
(Field Installed)
2
LB LB
Receptacles
MAROON
BAND
N.E.C.
TAGS
G
B
W
120V POWER
MAROON
BAND
120V NEUTRAL
BROWN BAND
Fans
BROWN BAND
120V POWER
120V NEUTRAL
1
Fans
8 ft case has 2 Fans
12 ft case has 3 Fans
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
R = Red G = Green BL = Blue LB = Light Blue DB = Dark Blue B = Black W = White
Electric Service Receptacle
Page 7
7 of 7P/N 0518276_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
12 Ft
12 Ft
connectors
connectors
4
3
connectors
G
R
BL
BL
R
G
4
BL
R
BL
W
BG
B
connectors
W
4
3
connectors
G
R
BL
BL
R
G
4
BL
R
BL
4
3
connectors
G
R
BL
BL
R
G
4
BL
R
BL
Light Circuits
W
BG
Optional Shelf Harness
and Light Circuits
Standard Lighting, 2 Row Canopy
R = Red G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
3
4
4
120V NEUTRAL
ORANGE OR TAN BAND
R
R
BL
BL
BL
BL
W
Light
Switch
120V POWER
ORANGE OR TAN B
AND
B
W
R
R
BL
BL
R
BL
R
R
BL
BL
R
BL
BL
B
B
W
GG
G
G
G
G
G
G
G
G
G
R
3
3
4
4
4
4
44
4
R
R
BL
BL
R
BL
BL
G
G
G
3
44
4
Optional Ledge
Light Circuit
Optional
3 Row Canopy
12 Ft
Loading...