Hussmann SMBT Specifications

Page 1
T'Stat Bulb
Location
(Optional
Lights)
E
F
C
D
A
B
FAN ASSEMBLIES AND THERMOSTATS
A. 0392457 Fan Motor, Evaporator (120V) (1)
(MO.4410101)
0409512 Fan Blade (120V) (FB.0409512)
embossing toward motor
0436517 Fan Motor, Evaporator (220V)
(MO.4410105)
0409513 Fan Blade (220V) (FB.0409513)
embossing toward motor
B. 0404551 Fan Motor, Ambient (120V) (2)
(MO.0404551)
0404552 Fan Motor, Ambient (220V)
(MO.4410590)
C. 0382028 Standard Non-adjustable (3)
Defrost Thermostat (CT.0382028)
D. 0137880 Optional Adjustable (4)
Refrigeration Thermostat (CT.4481084)
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
E. Electronic Ballast (5)
0355716 2 lamps (120V) (BA.0355716) 0355398 3 lamps (120V) (BA.4480118)
0440215 2 lamps (230V 50-60 Hz)
(BA.4481267)
0428652 3 lamps (230V 50-60 Hz)
(BA.4480897)
0385104 Ballast Transformer
(230V 50-60 Hz, per ballast) (TR.4481191)
F. Fluorescent Lamp (6)
Replace with like fixtures
SMBT
Technical Data Sheet
P/N 0518274_A
NSF
®
Certified
November 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
P/N_0518274_A
Page 2
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length 48 1/4 (1226) 72 1/4 (1835) 96 3/8 (2448) 144 1/2 (3670)
Maximum O/S dimension of case back to front 44 5/
8 (1134) 44
5
/
8 (1134) 44
5
/
8 (1134) 44
5
/
8 (1134)
(Note: Includes bumper)
Back of case to front of splashguard 33
3
/8 (848) 33 3/8 (848) 33 3/8 (848) 33 3/8 (848)
Center of rear legs to center of front legs 25 5/8
(651) 25
5
/8
(651) 25
5
/8
(651) 25
5
/8
(651)
Each End and Partition adds 1
1
/2 in. (38 mm) to the length of the lineup.
Electrical Service
(B) RH end of case to Electrical raceway right edge 7 (178) 7 (178) 7 (178) 7 (178) (C) RH end of case to Electrical raceway left edge 41 3/8 (1051) 32 3/4 (831) 44 1/2 (1131) 44 1/2 (1131)
Back of case to center of knockout 3 5/8 (92) 3 5/8 (92) 3 5/8 (92) 3 5/8 (92)
* Electrical Field Wiring Connection Point
Waste Outlet
(D) RH end of case to the center of waste outlet 24 (610) 24 (610) 24 (610) 72 1/
4 (1835)
Back of case to center of waste outlet 25
5
/8 (652) 25 5/8 (652) 25 5/8 (652) 25 5/8 (652)
Water Seal
Center of tee to center of waste outlet 11 3/8 (289) 11 3/8 (289) 11 3/8 (289) 11 3/8 (289) Outside diameter of drip piping 1 1/
2 (38) 1
1
/
2 (38) 1
1
/
2 (38) 1
1
/
2 (38)
** Field installed water seal outlets, tees, and connectors are shipped with the merchandiser.
Refrigeration Outlet
Back of case to center of refrigeration outlet 28
3
/4 (731) 28 3/4 (731) 28 3/4 (731) 28 3/4 (731)
(E) RH end of case to center of refrigeration outlet 9 3/
8 (238) 9
3
/
8 (238) 9
3
/
8 (238) 9
3
/
8 (238)
Outside diameter of the liquid line
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
Outside diameter of the suction line
5
/8 (16)
5
/8 (16)
5
/8 (16)
5
/8 (16)
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
SMBT Technical Data Sheet 2 of 7
C
L
(See Note*)
25
5
/
8
(651)
25
5
/
8
(651)
Legs
28
3
/
4
(730)
Front
Refrigeration Outlet
Water Seal
Waste Outlet
Leg Center Lines
Electrical
44
5
/
8
(1133)
33
3
/
8
(849)
(See Note**)
SMBT SMGT SSGT
A
B
D
C
E
Dimensions shown as in. and (mm).
Meat & Delicatessen
Engineering
Plan Views
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
SMBT
Discharge Air (°F) 24
Evaporator (°F) 18
Unit Sizing (°F) 16
Btu/hr/ft SMBT
Parallel
420
Conventional
450
DEFROST DATA
SMBT
Frequency (hr) 12 Defrost Water (lb/ft/day) 0.20
(± 15% based on case configuration and
product loading).
O
FFTIME
SMBT Temp Term (°F) 43° Failsafe (minutes) 90
E
LECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
SMBT CI/CO (Temp °F)* 11°F / 1°F Indoor Unit Only, Pressure Defrost Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Estimated Charge (lb)**
4 ft 0.75 lb 12 0z 0.35 kg
6 ft 1.0 lb 16 0z 0.5 kg
8 ft 1.5 lb 24 0z 0.7 kg
12 ft 2.0 lb 32 oz 0.9 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg).
Length Added to Lineup by:
Each Plastic End w/ Bumper (in.) 3
1
/2
Each End/Partition (in.) 1
1
/2
3 of 7P/N 0518274_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
22
1
/2
(572)
SMBT
52
(1321)
33
5
/8
(854)
25
5/8 (651)
28
3
/
4
(730)
34
(864)
20
(508)
24
1
/4
(616)
13
3
/4
(349)
33
3
/
8
(849)
44
5
/
8
(1133)
3
5
/8
(92)
FAN
COIL
11
3
/8
(289)
10
1
/2
(267)
7
(178)
10
(254)
Refrig.
Outlet
Elec.
FAN
24
O
18
1
/2
(470)
Dimensions shown as in. and (mm).
Excel SMBT
Meat & Delicatessen
Flat Hinged Glass, Blower, 3 Display Level
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
SMBT Technical Data Sheet 4 of 7
Excel SMBT
Meat & Delicatessen
Electrical Data
Number of Fans 4 ft 6 ft 8 ft 12 ft Refrigeration (120V 60hz) – 4W 1 2 2 3 Ambient Air Wipe – 15W 2 4 4 6
Export Refrigeration (230V 50 hz ) – 4W 1 2 2 3 Export Ambient Air Wipe – 15W 2 4 4 6
Amperes Watts Merchandiser 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft Refrigeration Fans
Standard (120V 60hz) 0.31 0.62 0.62 0.93 24 48 48 72 Energy Efficient(120V 60hz) NA NA NA NA NA NA NA NA Export: 230V 50 hz 0.18 0.36 0.36 0.54 27 54 54 81
Ambient Air Wipe Fans
Standard (120V 60hz) 0.26 0.52 0.52 0.78 15 30 30 45 Energy Efficient(120V 60hz) NA NA NA NA NA NA NA NA Export: 230V 50 hz 0.13 0.26 0.26 0.39 15 30 30 45
Constant On Anti-sweat Heaters NA NA NA NA NA NA NA NA
Cycling Anti-sweat Heaters NA NA NA NA NA NA NA NA
Minimum Circuit Ampacity
With Standard Fans (120V 60hz) 0.77 1.34 1.34 1.91 With Energy Efficient Fans (120V 60hz) NA NA NA NA With Export Fans (230V 50 hz ) 0.51 0.82 0.82 1.13
Maximum Over Circuit Protection 120V 20 20 20 20
Electric Defrost Heaters (208V) NA NA NA NA NA NA NA NA Gas Defrost Heaters (208V) NA NA NA NA NA NA NA NA
Standard Lighting* (120V 60hz) 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
2 Row Canopy 0.49 0.80 0.98 1.42 58 92 116 170 1 Row Rail 0.49 0.40 0.49 0.71 58 46 58 85
Optional Lighting
1 Row Ledge 0.49 0.40 0.49 0.71 58 46 58 85 2 Row Shelves 0.49 0.80 0.98 1.42 58 92 116 170
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52do
Page 5
5 of 7P/N 0518274_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
5
Glass /
Case Solid End Plastic End
4 ft 6 ft 8 ft 12 ft (each) (each)
lb (kg) 700 (318) 800 (363) 900 (408) 1300 (590) 70 (32) 100 (45)
5
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 2.61 ft3 /ft (0.24 m3 /m)
ARI Total Display Area
2
(Sq Ft/Ft) 1.86 ft2/ft (0.57 m2 /m)
Shelf Area 3(Sq Ft/Ft) 4.22 ft2/ft (1.29 m2 /m)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is one 7-inch shelf and one 10-inch shelf.
Excel SMBT
Meat & Delicatessen
Page 6
SMBT Technical Data Sheet 6 of 7
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Fan Wiring
Offtime Defrost
Electric Service Receptacle
120V NEUTRAL
MAROON
BAND
120V POWER
W
B
G
N.E.C.
TAGS
MAROON
BAND
Defrost Termination Thermostat
Refrigeration
Thermostat
To Condensing Unit
}
(Field Installed)
3
4
DB
DB
LB
LB
BROWN BAND
Fans
BROWN BAND
120V POWER
120V NEUTRAL
1
Fans
4 ft case has 1 Fan 6 ft case has 2 Fans 8 ft case has 2 Fans
12 ft case has 3 Fans
BROWN BAND
Fans
BROWN BAND
120V POWER
120V NEUTRAL
2
Fans
Ambient Fan
Wiring
Glass Air Wipe
R = Red G = Green BL = Blue LB = Light Blue DB = Dark Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
Receptacles
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
4 ft case has 2 Fan 6 ft case has 3 Fans 8 ft case has 4 Fans
12 ft case has 6 Fans
Page 7
7 of 7P/N 0518274_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Light Circuits
6
5
connectors
G
R
BL
BL
R
G
6
BL
R
BL
6
5
connectors
G
R
BL
BL
R
G
6
BL
R
BL
W
B
G
connectors
W
BG
Optional Shelf Harness
and Light Circuits
Standard Lighting
2 Row Canopy,
1 Row Interior Rail
R = Red G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
= Case GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
Circled Numbers = Parts List Item Numbers
Grayed components in 12 foot models only.
5
6
6
120V NEUTRAL
ORANGE OR TAN BAND
R
R
BL
BL
BL
BL
W
Light
Switch
120V POWER
ORANGE OR TAN B
AND
B
W
R
R
BL
BL
R
BL
R
R
BL
BL
R
BL
BL
B
B
W
GG
G
G
G
G
G
G
G
G
G
R
5
5
6
6
6
6
66
6
R
R
BL
BL
R
BL
BL
G
G
G
5
66
6
Optional Ledge
Light Circuit
Rail Light Circuit
6
5
connectors
G
R
BL
BL
R
G
6
BL
R
BL
connectors
W
B
G
Loading...