Hussmann SI3 Specifications

D
SI3
Technical Data Sheet
P/N 0492431_D
NSF
Certified
April 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
12 Ft, 14 Ft & 16 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0407532 Fan Blade (FB.4780619)
(12 ft & 14 ft only) embossing toward motor
0506563 Fan Blade (FB.4780811)
(16 ft only) embossing toward motor
12 Ft & 16 Ft
A. 12W Energy Efficient Fan Assembly (1)
0477655 Fan Motor, Evaporator
(MO.4410546)
0407532 Fan Blade (FB.4780619)
(12 ft only) embossing toward motor
0506563 Fan Blade (FB.4780811)
(16 ft only) embossing toward motor
B. Optional Adjustable Refrigeration Thermostat (2)
0448347 (CT.4481631)
Item Part # Description Wiring Item #
H
EATERS
C. Anti-Sweat Heater (3)
0491966 12 ft (HE.4850834) 0487120 14 ft (HE.4850835) 0487121 16 ft (HE.4850836)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0355398 3 Lamps (BA.4480118) 0355716 2 Lamps (BA.0355716) 0447739 (BA.4480900) 0447740 (BA.4481278)
E. Fluorescent Lamp (5)
Replace with like fixtures
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
P/N0492431D
Note: Revision D updates energy efficient motor Btu note on page 3.
B
®
E
C
E
A
Serial Plate
2 of 7
SI3 Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
08-2009
Front
12 ft 14 ft 16 ft
General
(A) Overall Case Length 144 (3658) 168 (4267) 192 (4877) (B) Base Length 125 (3175) 149 (3785) 173 (4394)
Maximum O/S dimension of case back to front (includes bumper) 72 (1829) 72 (1829) 72 (1829) Front of splashguard to O/S edge of front base rail 1
5
/8 (41) 1 5/8 (41) 1 5/8 (41)
Front of case to O/S edge of front base rail 13
1
/8 (333) 13 1/8 (333) 13 1/8 (333)
Back of case to O/S edge of front base rail 58
7
/
8 (1495) 58
7
/
8 (1495) 58
7
/
8 (1495)
Width of base rail 1
7
/8 (48) 1 7/8 (48) 1 7/8 (48)
(D) Length of Canopy
Width of Canopy 18
1
/8 (460) 18 1/8 (460) 18 1/8 (460)
Electrical Service (Electrical Field Wiring connection point)
Center of Electrical service to O/S edge of front base rail 47 (1194) 47 (1194) 47 (1194) Left end of case to center of field connection box 27 (686) 27 (686) 27 (686) Right end of case to center of field connection box 117 (2972) 141 (3581) 165 (4191)
Waste Outlets
(C) LH End of case to the center of waste outlet 42 (1067) 84 (2134) 96 (2438)
Center of front waste outlet to outside of front base rail 8
7
/8 (225) 8 7/8 (225) 8 7/8 (225)
Center of back waste outlet to outside of front base rail 40
1
/8 (1019) 40 1/8 (1019) 40 1/8 (1019)
Schedule 40 PVC drip pipe 1
1
/2 (38) 1 1/2 (38) 1 1/2 (38)
Refrigeration Outlet
LH end of case to center of refrigeration outlet 22 (559) 22 (559) 22 (559) RH end of case to center of refrigeration outlet 122 (3099) 146 (3708) 170 (4318)
SI3 Island
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Dimensions shown as inches and (mm).
27
(686)
22
(559)
C
Field Connection Electrical Box
A
Serial
Plate
(1829)
31 1/4
(794)
47
(1194)
7
(178)
32 1/2
(826)
Refrigeration Outlets
Canopy
Waste Outlets
18 1/8
(460)
11 1/2
(292)
D
9 1/2
(241)
B
20 3/8
(518)
72
3 of 7P/N 0492431_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
SI3
Discharge Air (°F) 27
Evaporator (°F) 20
Unit Sizing (°F) 18
Btu/hr/ft
L
IT & UNLIT SHELVES SI3
Parallel 1820
Conventional 1985
Optional energy efficient motors reduce the
refrigeration load by 91 Btu/hr/ft.
DEFROST DATA
SI3
Frequency (hr) 4
Defrost Water (lb/ft/day) 12
(± 15% based on case configuration and
product loading).
OFFTIME SI3
Time Terminated (minutes) 20
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
SI3
CI/CO* 14°F / 4°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
* Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** SI3
12 ft 2.5 lb 40 oz 1.1 kg
14 ft 3.1 lb 50 oz 1.4 kg
16 ft 3.7 lb 59 oz 1.7 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
SI3
Delicatessen
NSF®Certification
This merchandiser is manufactured to meet ANSI/NSF
®
(National Sanitation
Foundation) Standard #7 requirements for construction, materials & cleanability.
Multi-deck Island, 4 Display Levels
SI3
Load Limit Profile
Air flow between the shelves, from the Center Air Discharge (CAD) to the return, must be maintained at all times for optimum operating efficiency and to prolong product shelf life. At no time should merchandisers be stocked beyond the load limits indicated.
Cases may not function properly if they are loaded above load limits.
18 1/8
(460)
8
(203)
12
51 3/4
(1315)
8 7/8
(225)
Standard Height Plex
and Product Stop
5 7/8 (149)
3 (76)
30 3/4 (781)
(686)
27
(305)
16
(406)
Optional High Plex
and Product Stop
6 (152)
3 1/4 (83)
10 7/8
(276)
11 1/2
(292)
49 (1245)
11 1/2
(292)
14 1/8
(359)
72 (1829)
CAD
Load Limit
Optional Shelves
Optional High Plex with 6 in. (152 mm) Product Depth
Load Limit
SI3
Loading...
+ 4 hidden pages