SI2E
Technical Data Sheet
P/N 0510792_B
NSF
®
Certified
April 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
10 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0141070 Fan Blade (FB.0141070)
embossing toward motor
B. Optional Adjustable Refrigeration Thermostat (2)
0448347 (CT.4481631)
Item Part # Description Wiring Item #
HEATERS
C. Anti-Sweat Heater (3)
0487124 10 ft (HE.4851035)
0487125 10 ft (HE.4851036)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0355398 3 Lamps (BA.4480118)
0355716 2 Lamps (BA.0355716)
0447739 (BA.4480900)
E. Fluorescent Lamp (5)
Replace with like fixtures
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
P/N0510792B
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Note: Revision B updates electrical data on page 4 and updates anti-sweat electrical schematic on page 6.
E
C
E
B
D
A
Serial Plate
10 ft
General
(A) Overall Case Length 120 (3048)
(B) Base Length 110 1/2 (2807)
Maximum O/S dimension of case back to front
(includes bumper) 72 (1829)
Front of splashguard to O/S edge of front base rail 1 5/8 (41)
Front of case to O/S edge of front base rail 13 1/8 (333)
Back of case to O/S edge of front base rail 58 7/
8 (1495)
Width of base rail 1
7
/8 (48)
(D) Length of Canopy 93 1/8 (2365)
Width of Canopy 18 1/
8 (460)
Electrical Service (Electrical Field Wiring connection point)
Center of Electrical service to O/S edge of front base rail 47 (1194)
Left end of case to center of field connection box 27 (686)
Right end of case to center of field connection box 93 (2362)
Waste Outlets
(C) LH End of case to the center of waste outlet 96 (2438)
Center of front waste outlet to outside of front base rail 8
7
/
8 (225)
Center of back waste outlet to outside of front base rail 40
1
/8 (1019)
Schedule 40 PVC drip pipe 1 1/2 (38)
Refrigeration Outlet
LH end of case to center of refrigeration outlet 22 (559)
RH end of case to center of refrigeration outlet 98 (2489)
2 of 7
SI2E Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
08-2009
Front
Dimensions shown as inches and (mm).
SI2E Island
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
47
(1194)
Serial
Plate
7
(178)
32 1/2
(826)
27
(686)
22
(559)
C
Field Connection
Electrical Box
Refrigeration
Outlets
Canopy
A
Waste
Outlets
18 1/8
(460)
(1829)
31 1/4
(794)
11 1/2
(292)
D
9 1/2
(241)
B
20 3/8
(518)
72
3 of 7P/N 0510792_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
SI2E
Discharge Air (°F) 27
Evaporator (°F) 20
Unit Sizing (°F) 18
Btu/hr/ft
L
IT & UNLIT SHELVES SI2E
Parallel 1444
Conventional 1575
DEFROST DATA
SI2E
Frequency (hr) 4
Defrost Water (lb/ft/day) 12
(± 15% based on case configuration and
product loading).
OFFTIME SI2E
Time Terminated (minutes ) 20
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
SI2E
CI/CO* 14°F / 4°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** SI2E
10 ft 2.10 lb 34 oz 1.0 kg
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by approximately half a pound.
Multi-deck Island, 3 Display Levels
SI2E
SI2E
Delicatessen
Load Limit Profile
Air flow between the shelves, from the Center Air Discharge (CAD) to the return, must be
maintained at all times for optimum operating efficiency and to prolong product shelf life.
At no time should merchandisers be stocked beyond the load limits indicated.
Cases may not function properly if they are loaded above load limits.
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation
Foundation) Standard #7 requirements for construction, materials & cleanability.
Standard Height Plex
7
5
/8 (149)
1
3
/4 (83)
23
(607)
and Product Stop
3 (76)
7
/8
1
11
/2
(292)
1
21
27 (686)
/2 (546)
1
18
/8
(460)
49 (1245)
72 (1829)
12
(305)
8 (203)
Optional High Plex
6 (152)
and Product Stop
8
1
11
/2
(292)
7
/8 (225)
27
(689)
1
55
/8
(1416)
3
/4
Optional Shelves
CAD
Load Limit
Optional High Plex
with 6 in. (152 mm)
Product Depth
Load Limit
SI2E