Hussmann SI1N Specifications

Page 1
P/N0492444C
®
SI1N
Technical Data Sheet
P/N 0492444_C
NSF
®
Certified
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Item Part # Description Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS 8 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0376413 Fan Blade (FB.0376413)
embossing toward motor
12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0376413 Fan Blade (FB.0376413)
embossing toward motor
B. Optional Adjustable Refrigeration Thermostat (2)
0448347 (CT.4481631)
Item Part # Description Wiring Item #
H
EATERS
C. 0447688 Anti-Sweat Heater (3)
(HE.4850682)
LAMPS AND BALLASTS
D. 0447683 Ballast, Electronic (4)
2 Lamps (BA.4440811)
E. Fluorescent Lamp (5)
Replace with like fixtures
Note: Revision C adds energy efficient fan Btu note on page 3.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Page 2
2 of 7
SI1N Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
08-2009
Front
8 ft
General
(A) Overall Case Length 96 (2438) (B) Base Length 77 (1956)
Maximum O/S dimension of case back to front (includes bumper) 60 (1524) Front of splashguard to O/S edge of front base rail 1 5/8 (41) Front of case to O/S edge of front base rail 13 1/8 (333) Back of case to O/S edge of front base rail 58 7/
8 (1495)
Width of base rail 1
7
/8 (48)
(D) Length of Canopy 61 5/8 (1565)
Width of Canopy 13
5
/8 (346)
Electrical Service (Electrical Field Wiring connection point)
Center of Electrical service to O/S edge of front base rail 47 (1194) Left end of case to center of field connection box 27 (686) Right end of case to center of field connection box 69 (1753)
Waste Outlets
(C) LH End of case to the center of waste outlet 48 (1218)
Center of front waste outlet to outside of front base rail 8 7/8 (225) Center of back waste outlet to outside of front base rail 40
1
/8 (1019)
Schedule 40 PVC drip pipe 1 1/2 (38)
Refrigeration Outlet
LH end of case to center of refrigeration outlet 22 (559) RH end of case to center of refrigeration outlet 74 (1880)
SI1N Island
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Dimensions shown as inches and (mm).
47
(1194)
Serial
Plate
7
(178)
26 1/2
(673)
A
C
27
(686)
22
(559)
Field Connection Elect. Box
Refrig. Outlets
Waste Outlets
Canopy
60
(1524)
13 5/8
(346)
31 1/4
(794)
5 1/2
(140)
9 1/2
(241)
D
B
14 3/8
(365)
Page 3
3 of 7P/N 0492444_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF®Certification
This merchandiser is manufactured to meet ANSI/NSF
®
(National Sanitation
Foundation) Standard #7 requirements for construction, materials & cleanability.
Single Deck Island, 1 Display Level, Narrow Footprint
SI1N
SI1N
Delicatessen
Load Limit Profile
Air flow between the shelves, from the Center Air Discharge (CAD) to the return, must be maintained at all times for optimum operating efficiency and to prolong product shelf life. At no time should merchandisers be stocked beyond the load limits indicated.
Cases may not function properly if they are loaded above load limits.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
SI1
Discharge Air (°F) 27
Evaporator (°F) 15
Unit Sizing (°F) 13
Btu/hr/ft
L
IT & UNLIT SHELVES SI1
Parallel 1260
Conventional 1375
Optional energy efficient motors reduce the
refrigeration load by 55 Btu/hr/ft.
DEFROST DATA
SI1
Frequency (hr) 4
Defrost Water (lb/ft/day) 9
(± 15% based on case configuration and
product loading).
OFFTIME SI1
Time Terminated (minutes) 20
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
SI1
CI/CO* 8°F / –2°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge ** SI1
8 ft 1.7 lb 27 oz 0.8 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Dimensions shown as inches and (mm).
5
13
7
5
3
Standard Height Plex
and Product Stop
/8 (149)
1
/4 (83)
7
23
/8
(607)
1
5
/2
(140)
3 (76)
21 (533)
/8
(346)
49 (1245)
4 (102)
10
Optional High Plex
and Product Stop
1
(260)
/8
6 (152)
8
7
/8 (225)
27
(689)
1
5
/2
(140)
1
/8
44
(1127)
3
/8
60 (1524)
Optional High Plex
3 in. Space Required
CAD
Load Limit
with 6 in. (152 mm) Product Depth
Load Limit
SI1N
Page 4
4 of 7
SI1N Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
SI1N
Delicatessen
Electrical Data
8 ft
Number of Fans – 12W 4
Amperes Watts
8 ft 8 ft
Evaporator Fan
120V 60Hz Standard 2.60 200
120V 50Hz Standard 3.00 228
230V 60Hz Export NA NA
230V 50Hz Export NA NA
120V 60Hz Energy Efficient 1.20 72
230V 60Hz Energy Efficient NA NA
Anti-sweat Heaters
120V 50/60Hz Standard 1.00 120
230V 50/60Hz Export NA NA
Minimum Circuit Ampacity (MCA)
120V 60Hz Standard 3.80
120V 50Hz Standard 3.72
230V 60Hz Export NA
230V 50Hz Export NA
120V 60Hz Energy Efficient 1.92
230V 60Hz Energy Efficient NA
Maximum Over Current Protection 120V 20
Maximum Over Current Protection 230V NA
Standard Lighting
1 Row Canopy 0.80
Optional Lighting
1 Row of Ledge 1.67
Optional Shelf Lighting
None
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
Page 5
5 of 7P/N 0492444_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case
8 ft End
lb (kg) 1000 (454) NA
4
Actual weights will vary according to optional kits included.
Product Data
SI1N8
Recommended Usable Cube 1 (Cu Ft/Case) 14.00 ft3 /case (0.40 m3/case) AHRI Total Display Area 2 (Sq Ft/Case) 27.47 ft2 /case (2.55 m2 /case) Shelf Area 3(Sq Ft/Case) 28.00 ft2 /case (2.60 m2 /case)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume / Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2] / Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product
Reference Guide. The standard shelf complement for this model is none.
SI1N
Delicatessen
Page 6
6 of 7
SI1N Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Fan Wiring Offtime Defrost
4 Fans
8 ft
120V NEUTRAL
120V P
OWER
BROWN BAND
BROWN BAND
1
1
Refrigeration Thermostat
2
Light Blue
To Condensing
}
Unit
Fans
Anti-sweat Heater
BROWN BAND
BROWN BAND
3
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120VPOWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
Page 7
7 of 7P/N 0492444_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
120V NEUTRAL
Light Circuits
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
G
Optional Ledge Light Circuit
W
G
B
4
R
BL R BL R BL R
G
BL
5
G G
BL
5
5
4
R
BL R BL R BL R
G G G
BL
5
BL
5
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120VPOWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND