SI1E
Technical Data Sheet
P/N 0510791_B
NSF
®
Certified
April 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
8 Ft & 10 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0376413 Fan Blade (FB.0376413) (8 ft Only)
embossing toward motor
0141070 Fan Blade (FB.0141070) (10 ft Only)
embossing toward motor
8 Ft Only
A. 12W Energy Efficient Fan Assembly (1)
0477655 Fan Motor, Evaporator
(MO.4410546)
0376413 Fan Blade (FB.0376413)
embossing toward motor
10 Ft Only
B. Optional Adjustable Refrigeration Thermostat (2)
0448347 (CT.4481631)
Item Part # Description Wiring Item #
HEATERS
C. 0447688 Anti-Sweat Heater (3)
(HE.4850682)
L
AMPS AND BALLASTS
D. 0355716 Ballast, Electronic (4)
2 Lamps (BA.0355716)
E. Fluorescent Lamp (5)
Replace with like fixtures
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Note: Revision B updates energy efficient fan Btu note on page 3 and updates electrical data on page 4.

8 ft 10 ft
General
(A) Overall Case Length 96 (2438) 120 (3048)
(B) Base Length 76 3/
4 (1950) 110
1
/
2 (2807)
Maximum O/S dimension of case back to front (includes bumper) 72 (1829) 72 (1829)
Front of splashguard to O/S edge of front base rail 1
5
/8 (41) 1 5/8 (41
Front of case to O/S edge of front base rail 13 1/
8 (333) 13
1
/
8 (333)
Back of case to O/S edge of front base rail 58
7
/8 (1495) 58 7/8 (1495)
Width of base rail 1 7/8 (48) 1 7/8 (48)
(D) Length of Canopy 69 1/8 (1756) 93 1/8 (2365)
Width of Canopy 13 5/8 (346) 13 5/8 (346)
Electrical Service (Electrical Field Wiring connection point)
Center of Electrical service to O/S edge of front base rail 47 (1194) 47 (1194)
Left end of case to center of field connection box 27 (686) 27 (686)
Right end of case to center of field connection box 69 (1753) 93 (2362)
Waste Outlets
(C) LH End of case to the center of waste outlet 81 (2057) 96 (2438)
Center of front waste outlet to outside of front base rail 8 7/8 (225) 8 7/8 (225)
Center of back waste outlet to outside of front base rail 40
1
/8 (1019) 40 1/8 (1019)
Schedule 40 PVC drip pipe 1
1
/2 (38) 1 1/2 (38)
Refrigeration Outlet
LH end of case to center of refrigeration outlet 22 (559) 22 (559)
RH end of case to center of refrigeration outlet 74 (1880) 98 (2489)
2 of 7
SI1E Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
08-2009
SI1E Island
Front
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Dimensions shown as inches and (mm).
A
C
27
(686)
22
(559)
Serial
Plate
Field Connection
Electrical Box
72
(1829)
31 1/4
(794)
47
(1194)
7
(178)
32 1/2
(826)
Refrigeration
Outlets
Canopy
Waste
Outlets
13 5/8
(346)
11 1/2
(292)
D
9 1/2
(241)
B
20 3/8
(518)

3 of 7P/N 0510791_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Dimensions shown as inches and (mm).
SI1E
Delicatessen
NSF®Certification
This merchandiser is manufactured to meet ANSI/NSF
®
(National Sanitation
Foundation) Standard #7 requirements for construction, materials & cleanability.
Single Deck Island End, 1 Display Level
SI1E
Load Limit Profile
Air flow between the shelves, from the Center Air Discharge (CAD) to the return, must be
maintained at all times for optimum operating efficiency and to prolong product shelf life.
At no time should merchandisers be stocked beyond the load limits indicated.
Cases may not function properly if they are loaded above load limits.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
SI1E
Discharge Air (°F) 27
Evaporator (°F) 15
Unit Sizing (°F) 13
Btu/hr/ft
‡
SI1E
Parallel 1260
Conventional 1375
‡
Optional energy efficient motors reduce the
refrigeration load by 82 Btu/hr/ft.
DEFROST DATA
SI1E
Frequency (hr) 4
Defrost Water (lb/ft/day) 9
(± 15% based on case configuration and
product loading).
OFFTIME SI1E
Time Terminated (minutes) 20
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
SI1E
CI/CO* 8°F / –2°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge ** SI1E
8 ft 1.7 lb 27 oz 0.8 kg
10 ft 2.1 lb 34 oz 1.0 kg
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Standard Height Plex
and Product Stop
13
(346)
5
3 (76)
5
3
7
/8 (149)
1
/4 (83)
23
(607)
7
/8
27 (686)
/8
4 (102)
10
1
/8
Optional High Plex
(260)
6 (152)
and Product Stop
8
7
/8 (225)
44
(1127)
1
27
/8
(689)
3
/8
11
(292)
1
/2
49 (1245)
11
(292)
1
/2
72 (1829)
Optional High Plex
3 in. Space Required
CAD
Load Limit Load Limit
with 6 in. (152 mm)
Product Depth
SI1E

4 of 7
SI1E Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
SI1E
Delicatessen
Electrical Data
8 ft 10 ft
Number of Fans – 12W 6 8
Amperes Watts
8 ft 10 ft 8 ft 10 ft
Evaporator Fan
120V 60Hz Standard 3.90
5.20 300 400
120V 50Hz Standard 4.50
6.00 342 456
230V 60Hz Export NA NA NA NA
230V 50Hz Export NA NA NA NA
120V 60Hz Energy Efficient 1.80 NA 108 NA
230V 60Hz Energy Efficient NA NA NA NA
Anti-sweat Heaters †
120V 50/60Hz Standard 1.00 1.00 120 120
230V 50/60Hz Export NA NA NA NA
Minimum Circuit Ampacity (MCA) †
120V 60Hz Standard 5.10
6.40
120V 50Hz Standard 5.70 7.20
230V 60Hz Export NA NA
230V 50Hz Export NA NA
120V 60Hz Energy Efficient 3.00 NA
230V 60Hz Energy Efficient NA NA
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V NA NA
Standard Lighting
1 Row Canopy .49 .98 64 128
Optional Lighting
1 Row of Ledge 1.33 1.67 160 200
Optional Shelf Lighting
None
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting

5 of 7P/N 0510791_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case
8 ft 10 ft End
lb (kg) 1100 (499) 1200 (544) NA
4
Actual weights will vary according to optional kits included.
Product Data
SI1E8
Recommended Usable Cube 1 (Cu Ft/Case) 18.00 ft3 /case (0.51 m3/case)
AHRI Total Display Area 2 (Sq Ft/Case) 34,02 ft2 /case (3.16 m2 /case)
Shelf Area 3(Sq Ft/Case) 36.00 ft2 /case (3.34 m2 /case)
SI1E10
Recommended Usable Cube 1 (Cu Ft/Case) 22.50 ft3 /case (0.64 m3/case)
AHRI Total Display Area 2 (Sq Ft/Case) 42.53 ft2 /case (3.95 m2 /case)
Shelf Area 3(Sq Ft/Case) 45.00 ft2 /case (4.18 m2 /case)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume / Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2] / Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product
Reference Guide. The standard shelf complement for this model is none.
SI1E
Delicatessen

6 of 7
SI1E Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Fan Wiring
Offtime Defrost
6 & 8 Fans
8 ft
10 ft
120V NEUTRAL
120V P
OWER
BROWN BAND
BROWN BAND
1
1
Refrigeration Thermostat
2
Light Blue
To
Condensing
}
Unit
Fans
Anti-sweat Heater
BROWN BAND
BROWN BAND
3
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120VPOWER
= 120V NEUTRAL = FIELD GROUND
= CASE GROUND

7 of 7P/N 0510791_B
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
Light
Switch
B
W
G
Optional Ledge Light Circuit
W
G
B
4
BL R BL R BL R
G
BL
R
5
G G
BL
5
5
4
BL R BL R BL R
G G G
BL
R
5
BL
5
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120VPOWER
= 120V NEUTRAL = FIELD GROUND
= CASE GROUND