Hussmann SHVSS-C, SHVSS-R, SHVSS-S, SHVSS Technical Data Sheet

4
p
p
N
B
p
Specialty Products
CUL Listed
These merchandisers are manufactured to meet ANSI/National Sanitation Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
roduct design in connection with any feature of our
roducts. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
UL Sanitation
SHVSS
1 of 4
SHVSS
Technical Data Sheet
Rev A
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 30 Evaporator (F) 20
ote: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
tu/hr/ft*
Parallel 860
Conventional 989
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs 8
OFFTIME Temp Term °F 54 Failsafe Minutes 36
ELECTRIC or GAS Not Recommended
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.) 3/8* Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual refrigerant charge may vary by approximately half a
ound.
GPM PSI
4ft 1.2 4.0 5ft 1.5 5.8 6ft 1.8 9.0
PHYSICAL DATA
4ft 1.2 5ft 1.5 6ft 1.8
GLYCOL REQUIREMENTS
4
Engineering
CROSS SECTION
Specialty Products
SHVSS
SHVSS
Technical Data Sheet
Rev A
Engineering
Plan View
2 of 4
4
Specialty Products
SHVSS
SHVSS
Technical Data Sheet
Rev A
3 of 4
4
Specialty Products
SHVSS
SHVSS
Technical Data Sheet
Rev A
4 of 4