Hussmann RM Innovator Specifications

Page 1
E
C
B
A
D
G
F
Merchandisers
®
FAN ASSEMBLIES, AND THERMOSTATS
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Optional Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
B. Optional Adjustable (2)
Refrigeration Thermostat
CONTROL (RMF ONLY)
C. Fan Control (RMF) (3)
0125275 Fan Speed Control,
120V, 60hz (CT.4440734)
LAMPS. BALLASTS, LED FIXTURES AND POWER SUPPLY
D. 0489698 2 Lamp Ballast (BA.4481596)
0489699 3 Lamp Ballast (BA.4481739) 0424649 Export Ballast (BA.0424649)
E. Standard Fluorescent Lamp
Replace with like fixtures
F. 0499399 LED Power Supply (EP.4481668)
G. LED Fixture
Replace with like fixtures
NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available.
RM with INNOVATOR Doors
Technical Data Sheet
P/N 0425645_L
NSF
®
Certified
November 2009
Warning:
Terminal block NOT for
case-to-case
wire connection!
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
NOTE: Revision L updates Btu note, page 3.
P/N0425645L
Refer to I
NNOVATOR REACH-IN GLASS DOOR
I
NSTALLATION AND SERVICE
manual, P/N 0425683, for Innovator and Innovator II door and frame replacement parts.
Page 2
RM with Innovator Doors Technical Data Sheet
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
1 Dr 2 Dr 3 Dr 4 Dr 5 Dr
General
(A) Case Length (without ends or partitions) 31 1/2 (800) 62 (1575) 92 1/2 (2350) 122 7/8 (3121) 153 3/8 (3896)
(Each end adds 2 in. (51 mm) to length of lineup; each insulated partition adds 1 1/2 in. (38 mm).
Maximum O/S dimension of case back to front 43 3/4 (1111) 43 3/4 (1111) 43 3/4 (1111) 43 3/4 (1111) 43 3/4 (1111)
(Includes bumper. Add 26 1/2 in. (673 mm) for door swing.)
Back of case to rear of splashguard 39 7/8 (1013) 39 7/8 (1013) 39 7/8 (1013) 39 7/8 (1013) 39 7/8 (1013)
Width of Skidrail 3 3/4 (95) 3 3/4 (95) 3 3/4 (95) 3 3/4 (95) 3 3/4 (95)
Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152) 6 (152)
Stub-up area between front support and splashguard 3 1/8 (79) 3 1/8 (79) 3 1/8 (79) 3 1/8 (79) 3 1/8 (79)
Electrical Service
RH end of case to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102) 4 (102)
RH end of case to the center of LH knockout 27 1/2 (698) 58 (1473) 88 1/2 (2248) 118 7/8 (3019) 149 3/8 (3794)
Back O/S of case to center of knockout 41 5/8 (1058) 41 5/8 (1058) 41 5/8 (1058) 41 5/8 (1058) 41 5/8 (1058)
* NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(B) Right end of case to center of waste outlet 15 3/4 (400) 23 7/8 (606) 54 1/4 (1378) 46 1/4 (1175) 76 5/8 (1946)
Back O/S of case to center of waste outlet 34 5/8 (879) 34 5/8 (879) 34 5/8 (879) 34 5/8 (879) 34 5/8 (879)
Water Seal
Edge of water seal to center of waste outlet 11 (279) 13 (330) 13 (330) 13 (330) 13 (330)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet 5 3/
8 (137) 5
3
/
8 (137) 5
3
/
8 (137) 5
3
/
8 (137) 5
3
/
8 (137)
Back O/S of case to center of refrigeration outlet 32 (813) 32 (813) 32 (813) 32 (813) 32 (813)
Outside bottom front supports from end of case 6
3
/
4 (170) 6
3
/
4 (170) 6
3
/
4 (170) 6
3
/
4 (170) 6
3
/
4 (170)
Center bottom front support from Centerline NA 24 (610) 24 (610) 24 (610) 24 (610)
Distance between Center and Outside supports will vary
4
(102)
43
3
/4
(1111)
Front
5-Door Shown
6
(152)
34
5
/8
(879)
32
(813)
5
5
/8
(143)
41
5
/8
(1057)
Refrig. Outlet
A
B
Electrical Wireway
Bottom Front Support
48
(1219)
Waste Outlet
Relay & Terminal
Block Location
Skid/ External Base
13/4
(44)
13/4
(44)
7
(178)
4
(102)
Splashguard
Clearance for Door Swing
26
1
/2
(673)
70
1
/4
(1784)
Dimensions shown as in. & (mm).
Reach-In
2, 3, 4 & 5 Door
Engineering
Plan Views
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
RL - RM - RMF
Plan View
07-2008
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity levels that do not exceed NSF guidelines.
MEDIUM TEMP
Discharge Air °F 32
Evaporator °F 27
Unit Sizing °F 25
NSF NSF
BTU/HR
/DOOR TYPE IT
YPE II
Temp (°F) /R.H. 75°/ 55% 80°/ 55%
Parallel 850 890
Conventional 890 930
*Optional LED lighting reduces refrigeration load by 100 Btu
/hr/Door. Optional Energy Efficient Fan motors reduce refrigeration load by 109 Btu/hr/Door.
DEFROST DATA
Frequency (hr) 24 Defrost Water (lb/Dr/day) 0.36 (± 15% based on case configuration and
product loading.)
E
LECTRIC
NA
Temp Term (°F) NA Failsafe (minutes) NA
G
AS Not Recommended
O
FFTIME
60 minutes
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO (Temp °F)* +20°/ +10°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)**
2Dr 1.8 4Dr 3.6 3Dr 2.7 5Dr 4.6
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by each
Standard End (in.) 2 Optional End with Window (in.) 1
1
/2
Optional Partition (in.) 1 1/2
4 3/4
(121)
32 (813)
34 5/8 (879)
2 5/8
(67)
2
1
/8
(54)
Fan
Coil
62 1/2
(1588)
22 Shelf
(559)
41
(1041)
27 7/8 (708)
Refrigeration Outlet
67
(1702) Frame
65 1/2
(1664)
Door
83
(2108)
82 1/4
(2089)
6
1
/4
(159)
13 1/8
(333)
Frame
41 7/8 (1064)
43 3/4 (1111 )
3 1/2
(89)
Dimensions shown as in. & (mm).
Reach-in 2, 3, 4 and 5 Door Models
Impact RM
With INNOVATOR Doors
Dairy, Deli, Beverages
3 of 6P/N 0425645_L
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
RM with Innovator Doors Technical Data Sheet
4 of 6
Impact RM
With INNOVATOR Doors
Dairy, Deli, Beverages
Hussmann recommends against frame heater cycling with
Innovator
doors to prevent door seals from freezing to the
frames and tearing.
Electrical Data
Number of Fans—12W 1 2 3 4 5
Amperes Watts
Merchandiser 1Dr 2Dr 3Dr 4Dr 5Dr 1Dr 2Dr 3Dr 4Dr 5Dr
Evaporator Fan
120V 60Hz Standard 0.65 1.30 1.95 2.60 3.25 50 100 150 200 250
120V 50Hz Standard 0.75 1.50 2.25 3.00 3.75 57 114 171 228 285
220V 60Hz Export NA 0.66 0.99 1.32 1.65 NA 100 150 200 250
220V 50Hz Export NA 0.76 1.14 1.52 1.90 NA 114 171 228 285
120V 60Hz Energy Efficient 0.30 0.60 0.90 1.20 1.50 18 36 54 72 90
220V 60Hz Energy Efficient NA 0.30 0.45 0.60 0.75 NA 36 54 72 90
Door Anti-sweat Heaters (on fan circuit) NA
Frame Anti-sweat Heaters (on fan circuit)
120V 50/60Hz Standard 0.89 1.34 1.79 2.24 107 161 215 269
220V 50/60Hz Export 0.49 0.73 0.98 1.22 107 161 215 269
Minimum Circuit Ampacity
120V 60Hz Standard 2.39 3.49 4.59 5.69
120V 50Hz Standard 2.59 3.79 4.99 6.19
220V 60Hz Export 1.35 1.92 2.50 3.07
220V 50Hz Export 1.45 2.07 2.70 3.32
120V 60Hz Energy Efficient 1.69 2.44 3.19 3.94
220V 60Hz Energy Efficient 0.99 1.38 1.78 2.17
Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 220V 15 15 15 15 15
Defrost NA
Standard Vertical Lighting 1Dr 2Dr 3Dr 4Dr 5Dr 1Dr 2Dr 3Dr 4Dr 5Dr
Innovator* Doors (120V) 1.00 1.50 2.00 2.50 3.00 120 180 240 300 360
(Export: 220V 50 hz) NA 0.84 1.12 1.40 1.68 NA 185 246 308 370
Optional LED Lighting
Hussmann EcoShine™ [27 W] (120V) 0.23 0.45 0.68 0.90 1.13 27 54 81 108 135 Hussmann EcoShine™
[27 W] [220V Export)] 0.12 0.25 0.37 0.49 0.61 27 54 81 108 135
Hussmann EcoShine™ EP [16 W] (120V) 0.13 0.27 0.40 0.53 0.67 16 32 48 64 80 Hussmann EcoShine™ EP
[16 W] [220V Exp)] 0.07 0.15 0.22 0.29 0.36 16 32 48 64 80
Hussmann EcoShine™ [20 W] (120V) 0.17 0.33 0.50 0.67 0.83 20 40 60 80 100 Hussmann EcoShine™
[20 W] [220V Export)] 0.08 0.17 0.25 0.33 0.42 20 40 60 80 100
Gelcore
(120V) 0.24 0.48 0.73 0.97 1.21 29 58 87 116 145
Gelcore
(120V) [220V (Export)] 0.13 0.26 0.40 0.53 0.66 29 58 87 116 145
* Innovator or Innovator II
Page 5
5 of 6P/N 0425645_L
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
1 Dr 2 Dr 3 Dr 4 Dr 5 Dr (each)
lb (kg) 617 (280) 997 (453) 1295 (589) 1595 (725) 1874 (852) 55 (25)
4
Actual weights will vary according to optional kits included.
Impact RM
With INNOVATOR Doors
Dairy, Deli, Beverages
Product Data
Recommended Usable Cube
1
(Cu Ft/Dr) 23.46 ft3 /Dr (0.66 m3 /Dr)
ARI Total Display Area
2
(Sq Ft/Dr) 13.31 ft2/Dr (1.24 m2 /Dr)
Shelf Area 3(Sq Ft/Dr) 29.32 ft2/Dr (2.72 m2 /Dr)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves.
Page 6
RM with Innovator Doors Technical Data Sheet
6 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
BK
Refer to Innovator Reach-In
Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
1
120V POWER
120V NEUTRAL
2P
Evaporator
Fans
26
2P
Frame Heaters
14
21
Offtime Defrost (standard)
Medium Temperature
3
BR
12
R
RMF &
RMNF Only
Fan Speed
Control
15 23
Terminal Blocks in Raceway
20
21
22
26
17
11 14
LIGHTS
(120V)
Refrigeration
Thermostat
(Optional)
Pink
2
}
To Condensing Unit
12
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S.
(Neutral)
PBRORPOR
Removable External
Jumpers
120V POWER
NEUTRAL
Medium Temperature with
Offtime Defrost
20
OR
Switch
17
BR
OR
BR
11 22
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BL = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
Loading...