Hussmann RLT Innovator Specifications

B
L
E
H
A
M
J
I
K
F
G
C
D
N
O
RLT
with
INNOVATOR
Doors
Technical Data Sheet
P/N 0445823_D
NSF
®
Certified
December 2009
Warning:
Terminal block NOT for
case-to-case
wire connection!
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
, AND T
HERMOSTATS
(A) Fan Assembly (1)
0477658
Standard Motor (Energy Efficient) (MO.4410549
)
0315470 Fan Blade (FB.0315470)
(B) 0331798 Standard Non-adjustable (2)
Defrost Thermostat (CT.4440256)
(C) Optional Adjustable
Refrigeration Thermostat (3)
(D) 0440423 Defrost Limit Thermostat (4)
(CT.4481089)
(E) 0446007 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater Thermostat (CT.4440353)
R
ELAYS
(F) 0342598 Control Relay (120V) (6)
(RL.4480238)
(G) 0342599 Control Relay (208V) (7)
(RL.4480237)
H
EATERS
(H) Electric Defrost Heaters (208V) (8)
0461938 (1) 2 Door Models (HE.4850354) 0461939 (1) 3 Door Models (HE.4850355) 0461940 (1) 4 Door Models (HE.4850356) 0461941 (1) 5 Door Models (HE.4850357)
(I) Drain Pan Heater (Electric & Kool Gas) (9)
(120V)
0508199
(1) 2 Door Models (HE.4851029)
0508200
(1) 3 Door Models (HE.4851030)
0508201
(1) 4 Door Models (HE.4850987)
0508202
(1) 5 Door Models (HE.4850988)
Item Part # (Qty) Description Wiring Item #
H
EATERS (
CONTINUED)
(J) Koolgas Supplemental Heater – Plenum (10)
(120V) 0452980 (1) 2 Door Models (HE.4850576) 0452981 (1) 3 Door Models (HE.4850577) 0452982 (1) 4 Door Models (HE.4850510) 0452983 (1) 5 Door Models (HE.4850578)
(K) Koolgas Supplemental Drain Pan (11)
Heater – Bottom – (120V) 0452970 (2) 2 Door Models (HE.4850350) 0452971 (2) 3 Door Models (HE.4850506) 0452972 (2) 4 Door Models (HE.4850661) 0452973 (2) 5 Door Models (HE.4850507)
L
AMPS, BALLASTS, LED FIXTURES AND POW ER SUPPLY
(L) 0489697 1 Lamp Ballast (BA.4481738)
0489698 2 Lamp Ballast (BA.4481596) 0424649 Export Ballast (BA.0424649)
(M) Standard Fluorescent Lamp
Replace with like fixtures
(N) Power Supply (O) LED Fixture
Replace with like fixtures
NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
222200VV PPaarrttss LLiisstt iiss oonn PPaaggee 88..
Note: Revision D incorporates 220V data (pages 4 & 8); revises LED data on page 4; other changes underlined.
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Refer to INNOVATOR REACH-IN GLASS DOOR INSTALLATION AND SERVICE MANUAL, P/N 0425683,
for Innovator door and frame replacement parts.
P/N0445823D
2 Dr 3 Dr 4 Dr 5 Dr
General
(A) Case Length (without ends or partitions) 62 (1575) 92 1/
2 (2350) 122
7
/
8 (3121) 153
3
/
8 (3896)
Maximum outside dimension of case back to front 42
1
/8 (1070) 42 1/8 (1070) 42 1/8 (1070) 42 1/8 (1070)
(Includes bumper)
Back of case to front of splashguard 39 (991) 39 (991) 39 (991) 39 (991) Width of Skid rail 3 3/4 (95) 3 3/4 (95) 3 3/4 (95) 3 3/4 (95) Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152) Stub-up area between front Skid rail and splashguard 6 1/
2 (165) 6
1
/
2 (165) 6
1
/
2 (165) 6
1
/
2 (165)
Electrical Service
Left hand end of case to the center of nearest knockout 2
3
/
4 (70) 2
3
/
4 (70) 2
3
/
4 (70) 2
3
/
4 (70)
Right hand end of case to the center of center knockout 56
3
/4 (1441) 87 1/4 (2216) 117 5/8 (2988) 148 1/8 (3762) Back outside of case to center of knockout 31 5/8 (803) 31 5/8 (803) 31 5/8 (803) 31 5/8 (803) Raceway Length 62 (1575) 62 (1575) 62 (1575) 62 (1575)
*NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(B) Right end of case to center of waste outlet 23 7/8 (606) 54 1/4 (1378) 46 1/4 (1175) 76 5/8 (1946)
Back outside of case to center of waste outlet 34 5/
8 (879) 34
5
/
8 (879) 34
5
/
8 (879) 34
5
/
8 (879)
Water Seal
Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 drip piping 1
1
/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case.
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet 7 1/
4 (184) 7
1
/
4 (184) 7
1
/
4 (184) 7
1
/
4 (184)
Back outside of case to center of refrigeration outlet 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140)
Outside bottom front supports from end of case 7 (178) 7 (178) 7 (178) 7 (178) Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610)
Distance between Center and Outside supports will vary. Top piping is standard in the RLT case.
RLT with Innovator Doors Technical Data Sheet
2 of 8
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Clearance for Door Swing
26
1
/2
(673)
68
5
/8
(1743)
42
1
/8
(1070)
Front
5-Door Shown
6
(152)
34
5
/8
(879)
5
1
/2
(140)
Refrig. Outlets (on top)
A
B
Electrical Wireway (on top)
Bottom Front Support
48
(1219)
Waste Outlet
Relay & Terminal
Block Location
Skid/ External Base
23/4
(70)
7
(178)
4
7
/8
(124)
4
7
/8
(124)
23/8
(60)
23/8
(60)
21/2
(64)
21/2
(64)
Splashguard
Dimensions shown as inches & (mm).
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Tall Reach-In
2, 3, 4 & 5 Door
Engineering
Plan Views
06-2009
3 of 8P/N 0445823_D
Impact RLT
With INNOVATOR Doors
Frozen Food & Ice Cream
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
FF IC Discharge Air (°F) –5 –12 Evaporator (°F) –11 –19 Unit Sizing (°F) –14 –22
Btu/hr/Door* FF IC Parallel
1355 1430
Conventional
1380 1460 *Optional LED lighting reduces refrigeration load by 75 Btu/hr/door.
DEFROST DATA
FF IC Frequency (hr) 24 24 Defrost Water (lb/Dr/day) 1.2 1.3 (± 15% based on case configuration and
product loading.)
ELECTRIC FF IC
Temp Term (°F) 54° 54° Failsafe (minutes) 48 48
G
AS
Duration (minutes) 22 22
O
FFTIME Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC CI/CO (Temp °F)** –18°/ –34° –26°/ –45° Indoor Unit Only, Pressure Defrost Termination (Temp °F)**
Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)***
2 Dr 3.2 3 Dr 4.7 4 Dr 6.3 5 Dr 8.1
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approx­imately half a pound.
Length Added to Lineup by each
Standard End (in.) 2 Optional End with Window (in.)1
1
/
2
Optional Partition (in.) 1 1/
2
3 1/2
(89)
29 5/8 (752)
1 5/8 (41)
RLT
FAN
C O
I
L
30 3/4 (781)
42 1/8 (1070)
20 (508)
24 5/8
(625)
22
(559)
63 5/8 (1616)
89
(2261)
86
(2184)
74 1/2
(1892) Frame
73 1/8
(1857)
Door
31 5/8 (803)
7 1/8 (181)
6 1/8
(156)
39 (991)
8 1/4 (210)
4 3/4
(121)
Dimensions shown as inches & (mm).
Tall Reach-in 2, 3, 4 and 5 Door Models
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Loading...