Item Part # Description Wiring Item #
F
AN ASSEMBLIES
, AND T
HERMOSTATS
(A) Fan Assembly (1)
0477658
Standard Motor (Energy Efficient) (MO.4410549
)
0315470 Fan Blade (FB.0315470)
(B) 0331798 Standard Non-adjustable (2)
Defrost Thermostat (CT.4440256)
(C) Optional Adjustable
Refrigeration Thermostat (3)
(D) 0440423 Defrost Limit Thermostat (4)
(CT.4481089)
(E) 0446007 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater Thermostat (CT.4440353)
R
ELAYS
(F) 0342598 Control Relay (120V) (6)
(RL.4480238)
(G) 0342599 Control Relay (208V) (7)
(RL.4480237)
H
EATERS
(H) Electric Defrost Heaters (208V) (8)
0461938 (1) 2 Door Models (HE.4850354) 0461939 (1) 3 Door Models (HE.4850355) 0461940 (1) 4 Door Models (HE.4850356) 0461941 (1) 5 Door Models (HE.4850357)
(I) Drain Pan Heater (Electric & Kool Gas) (9)
(120V)
0508199
(1) 2 Door Models (HE.4851029)
0508200
(1) 3 Door Models (HE.4851030)
0508201
(1) 4 Door Models (HE.4850987)
0508202
(1) 5 Door Models (HE.4850988)
Item Part # (Qty) Description Wiring Item #
H
EATERS (
CONTINUED)
(J) Koolgas Supplemental Heater – Plenum (10)
(120V) 0452980 (1) 2 Door Models (HE.4850576) 0452981 (1) 3 Door Models (HE.4850577) 0452982 (1) 4 Door Models (HE.4850510) 0452983 (1) 5 Door Models (HE.4850578)
(K) Koolgas Supplemental Drain Pan (11)
Heater – Bottom – (120V) 0452970 (2) 2 Door Models (HE.4850350) 0452971 (2) 3 Door Models (HE.4850506) 0452972 (2) 4 Door Models (HE.4850661) 0452973 (2) 5 Door Models (HE.4850507)
L
AMPS, BALLASTS, LED FIXTURES AND POW ER SUPPLY
(L) 0489697 1 Lamp Ballast (BA.4481738)
0489698 2 Lamp Ballast (BA.4481596) 0424649 Export Ballast (BA.0424649)
(M) Standard Fluorescent Lamp
Replace with like fixtures
(N) Power Supply (O) LED Fixture
Replace with like fixtures
NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
222200VV PPaarrttss LLiisstt iiss oonn PPaaggee 88..
Note: Revision D incorporates 220V data (pages 4 & 8); revises LED data on page 4; other changes underlined.
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Refer to INNOVATOR REACH-IN GLASS DOOR INSTALLATION AND SERVICE MANUAL, P/N 0425683,
for Innovator door and frame replacement parts.
P/N0445823D
Page 2
2 Dr 3 Dr 4 Dr 5 Dr
General
(A) Case Length (without ends or partitions) 62 (1575) 92 1/
2 (2350) 122
7
/
8 (3121) 153
3
/
8 (3896)
Maximum outside dimension of case back to front 42
1
/8 (1070) 42 1/8 (1070) 42 1/8 (1070) 42 1/8 (1070)
(Includes bumper)
Back of case to front of splashguard 39 (991) 39 (991) 39 (991) 39 (991) Width of Skid rail 3 3/4 (95) 3 3/4 (95) 3 3/4 (95) 3 3/4 (95) Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152) Stub-up area between front Skid rail and splashguard 6 1/
2 (165) 6
1
/
2 (165) 6
1
/
2 (165) 6
1
/
2 (165)
Electrical Service
Left hand end of case to the center of nearest knockout 2
3
/
4 (70) 2
3
/
4 (70) 2
3
/
4 (70) 2
3
/
4 (70)
Right hand end of case to the center of center knockout 56
3
/4 (1441) 87 1/4 (2216) 117 5/8 (2988) 148 1/8 (3762) Back outside of case to center of knockout 31 5/8 (803) 31 5/8 (803) 31 5/8 (803) 31 5/8 (803) Raceway Length 62 (1575) 62 (1575) 62 (1575) 62 (1575)
*NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(B) Right end of case to center of waste outlet 23 7/8 (606) 54 1/4 (1378) 46 1/4 (1175) 76 5/8 (1946)
Back outside of case to center of waste outlet 34 5/
8 (879) 34
5
/
8 (879) 34
5
/
8 (879) 34
5
/
8 (879)
Water Seal
Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 drip piping 1
1
/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case.
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet 7 1/
4 (184) 7
1
/
4 (184) 7
1
/
4 (184) 7
1
/
4 (184)
Back outside of case to center of refrigeration outlet 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140) 5
1
/
2 (140)
Outside bottom front supports from end of case 7 (178) 7 (178) 7 (178) 7 (178) Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610)
Distance between Center and Outside supports will vary. Top piping is standard in the RLT case.
RLT with Innovator Doors Technical Data Sheet
2 of 8
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Clearance for Door Swing
26
1
/2
(673)
68
5
/8
(1743)
42
1
/8
(1070)
Front
5-Door Shown
6
(152)
34
5
/8
(879)
5
1
/2
(140)
Refrig. Outlets (on top)
A
B
Electrical Wireway (on top)
Bottom Front Support
48
(1219)
Waste Outlet
Relay & Terminal
Block Location
Skid/ External Base
23/4
(70)
7
(178)
4
7
/8
(124)
4
7
/8
(124)
23/8
(60)
23/8
(60)
21/2
(64)
21/2
(64)
Splashguard
Dimensions shown as inches & (mm).
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Tall Reach-In
2, 3, 4 & 5 Door
Engineering
Plan Views
06-2009
Page 3
3 of 8P/N 0445823_D
Impact RLT
With INNOVATOR Doors
Frozen Food & Ice Cream
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
FF IC Discharge Air (°F) –5 –12 Evaporator (°F) –11 –19 Unit Sizing (°F) –14 –22
Btu/hr/Door* FF IC Parallel
1355 1430
Conventional
1380 1460 *Optional LED lighting reduces refrigeration load by 75 Btu/hr/door.
DEFROST DATA
FF IC Frequency (hr) 24 24 Defrost Water (lb/Dr/day) 1.2 1.3 (± 15% based on case configuration and
product loading.)
ELECTRIC FF IC
Temp Term (°F) 54° 54° Failsafe (minutes) 48 48
G
AS
Duration (minutes) 22 22
O
FFTIME Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC CI/CO (Temp °F)** –18°/ –34° –26°/ –45° Indoor Unit Only, Pressure Defrost Termination (Temp °F)**
Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)***
2 Dr 3.2 3 Dr 4.7 4 Dr 6.3 5 Dr 8.1
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approx­imately half a pound.
Length Added to Lineup by each
Standard End (in.) 2 Optional End with Window (in.)1
1
/
2
Optional Partition (in.) 1 1/
2
3 1/2
(89)
29 5/8 (752)
1 5/8 (41)
RLT
FAN
C O
I
L
30 3/4 (781)
42 1/8 (1070)
20 (508)
24 5/8
(625)
22
(559)
63 5/8 (1616)
89
(2261)
86
(2184)
74 1/2
(1892) Frame
73 1/8
(1857)
Door
31 5/8 (803)
7 1/8 (181)
6 1/8
(156)
39 (991)
8 1/4 (210)
4 3/4
(121)
Dimensions shown as inches & (mm).
Tall Reach-in 2, 3, 4 and 5 Door Models
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
RLT with Innovator Doors Technical Data Sheet
4 of 8
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
RLT
With INNOVATOR Doors
Frozen Food & Ice Cream
Hussmann recommends against frame heater cycling with
Innovator
doors to prevent door seals from freezing to the
frames and tearing.
Electrical Data
2Dr 3Dr 4Dr 5Dr
Number of Fans 2 3 4 5
Amperes Watts
2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Evaporator Fan
120V 60Hz Standard Energy Efficient 1.65 2.5 3.3 4.1 125 188 250 313
220V 60Hz Export Energy Efficient 0.91 1.38 1.82 2.26 125 188 250 313
Anti-Sweat Heaters
120V 50/60Hz Doors 1.35 2.03 2.7 3.38 162 243 324 405
120V 50/60Hz Frames 0.96 1.43 1.92 2.4 115 172 230 288
220V 50/60Hz Doors - Export 0.74 1.10 1.47 1.84 162 243 324 405
220V 50/60Hz Frames - Export 0.52 0.78 1.05 1.31 115 172 230 288
Minimum Circuit Ampacity
120V 60Hz Standard Electric Defrost 4.79 6.17 8.13 10.09
120V 60Hz Koolgas Defrost 2.37 3.46 4.34 5.61
220V 50/60Hz Export Electric Defrost 5.37 8.28 11.18 14.08
220V 50/60Hz Koolgas Defros 4.11 6.33 8.53 10.72
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 220V 20 20 20 20
Defrost
Drain Heaters (Kool-Gas or Electric)
120V 60Hz Standard 1.00 1.50 2.00 2.50 120 180 240 300
220V 50Hz Export 0.50 0.75 1.00 1.25 110 165 220 275
Kool-Gas Supplemental Heaters
120V 60Hz Standard 4.30 6.78 9.18 11.58 516 814 1102 1390
220V 50Hz Export 2.35 3.70 5.01 6.32 472 744 1007 1270
Electric Defrost Heater
208V 60Hz Standard 7.70 11.50 15.4 19.2 1600 2400 3200 4000
220V 50Hz Export 6.70 10.00 13.3 16.6 1465 2200 2930 3660
Standard Vertical Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Innovator Doors Innovator or Innovator II
120V 50/60Hz Standard 1.50 2.00 2.5 3.00 180 240 300 360
220V 50/60Hz Export 0.84 1.12 1.40 1.68 185 246 308 370
Optional LED Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Hussmann EcoShine™ Energy Plus
(120V) 0.30 0.45 0.60 0.75 36 54 72 90
Hussmann EcoShine™ Energy Plus [220V (Export)] 0.16 0.25 0.33 0.41 36 54 72 90
Hussmann EcoShine™
(120V) 0.45 0.68 0.90 1.13 54 81 108 135
Hussmann EcoShine™ [220V (Export)] 0.25 0.37 0.49 0.61 54 81 108 135
Hussmann Always*Bright™
(120V) 0.67 1.00 1.33 1.67 80 120 160 200
Hussmann Always*Bright™ [220V (Export)] 0.36 0.55 0.73 0.91 80 120 160 200
*Innovator or Innovator II
Page 5
5 of 8P/N 0445823_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
5
Case Solid End
1 Dr 2 Dr 3 Dr 4 Dr 5 Dr (each)
lb (kg) NA (NA) 926 (420) 1290 (585) 1637 (743) 2006 (910) 60 (27)
5
Actual weights will vary according to optional kits included.
Impact RLT
With INNOVATOR Doors
Frozen Food & Ice Cream
Product Data
Recommended Usable Cube
1
(Cu Ft/Dr) 24.95 ft3 /Dr (0.71 m3 /Dr)
ARI Total Display Area
2
(Sq Ft/Dr) 13.59 ft2/Dr (1.26 m2 /Dr)
Shelf Area 3(Sq Ft/Dr) 32.38 ft2/Dr (3.01 m2 /Dr)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (6) rows of 22-inch shelves.
Page 6
RLT with Innovator Doors Technical Data Sheet
6 of 8
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electric Defrost Sequence - Low Temperature
1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater.
2. If the Defrost Heater raises internal air temperature above 90°F, the Defrost Limit Thermostat (4) will open.
3. Temperature rise of the evaporator closes the Relay Control Thermostat (5) at about 35°F, energizing 120V A.S. Relay Coils (6). These relays’ contacts open the Frame and Door Heater Circuits, and prevent the Fan Circuit from energizing upon defrost termination.
4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan Relay Coil Circuits. The Drain Pan Heater goes off.
5. Temperature fall of the evaporator opens the Relay Control Thermostat (5) at about 20°F, de-energizing 120V A.S. Relay Coils (6). A.S. Relay Contacts close the Frame and Door Heater Circuits, and Fan Circuit.
C
OR
120V POWER
OR
Switch
17
20
NEUTRAL
C
208V
Evaporator Fan
Relay Coil
1
3
R
R
Defrost Heater
R
5
4
BB
7
R
N.C.
7
8
8
Defrost Limit
208V
208V
1
2
3
4
6
O.O.R.
Defrost Termination
Thermostat
Refrigeration
Thermostat
(Optional)
Pink
2
3
}
To Condensing Unit
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
COM
N.O.
Rod Heater (Drain)
9
Y
Y
N.C.
7
7
1
3
W
B
Relay Control
25
Fan Relay
B
5
6
B
B
COM
N.C.
6
A.S. Relay
24
Door A.S. Heaters
Frame A.S. Heaters
21
22
2P
P
2P
P
12
11
10
120V POWER
16
13
Terminal Blocks in Raceway
Low Temperature with
Electric Defrost
20
21
22
26
17
1234
56 7
81011 1413 16
LIGHTS
(120V)
DEFROST HEATERS
(208V)
CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the
circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240.
Low Temperature
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
Permanent Internal
Jumpers
R P
W
BRORRRRBKBKRRBKP2PBK BK ORBK 2P Y
14
26
C.O.R.
Removable External
Jumpers
DB
C.O.R.
2
Defrost Termination
Thermostat
FIELD WIRED
DB
NEUTRAL
Dark Blue
Refer to Innovator Reach-In
Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
C
6
120V
Fan Relay
N.C.
120V Fan
Relay Coil
6
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BL = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
Page 7
7 of 8P/N 0445823_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Gas Defrost Sequence - Low Temperature
1. Defrost vapor enters evaporator causing a rise in temperature. At about 35°F the Control Relay Thermostat
(5) closes
the Fan Relay Coil and Control Relay Coil
(6) circuit. The Coil opens the Fan, Door Heater, and Frame Heater circuits,
while energizing the Drain Pan, Bottom, and Plenum Heaters (9), (10) and (11).
2.
If the Drain Pan Heater (9) raises internal air temperature above 90°F, the Heater Limit Thermostat (4) will open.
3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20°F, the Control
Relay Thermostat will open, de-energizing the Control Relay Coil and Fan Relay Coil
(7). Control and Fan Relay’s will
open the Drain Pan Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits.
9
Permanent Internal
Jumpers
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
COM
N.O.
Rod Heater (Drain)
Y
Y
N.C.
6
6
1
3
W
B
Relay Control
c
25
Fan Relay
F
B
5
6
B
B
COM
N.C.
6
A.S. Relay
24
Door A.S. Heaters
Frame A.S. Heaters
22
2P
2P
P
12
10
120V POWER
13
26
C.O.R.
P
OR
120V POWER
OR
Switch
NEUTRAL
17
20
Terminal Blocks in Raceway
Low Temperature with
Gas Defrost
20
21
22
26
17
10 11 1413 16
LIGHTS
(120V)
Refrigeration
Thermostat
(Optional)
Pink
3
}
To Condensing Unit
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
P
W
BROR
BK
P
2P
BK BK ORBK 2P Y
Removable External
Jumpers
Low Temperature
16
6
Fan Relay
Coil
11
c
Defrost Limit
4
O.O.R.
14
21
NEUTRAL
Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
10
11
Koolgas Supplemental
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BL = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
Page 8
RLT with Innovator Doors Technical Data Sheet
8 of 8
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
B
L
E
H
A
M
J
I
K
F
G
C
D
N
O
Item Part # Description Wiring Item #
F
AN ASSEMBLIES,
AND THERMOSTATS
(A) Fan Assembly (1)
0435101 Standard Motor (Energy Efficient)
(MO.4410574)
0315470 Fan Blade (FB.0315470)
(B) 0331798 Standard Non-adjustable (2)
Defrost Thermostat (CT.4440256)
(C) Optional Adj. Refrigeration Thermostat (3) (D) 0440423 Defrost Limit Thermostat (CT.4481089) (4) (E) 0446007 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater Thermostat (CT.4440353)
R
ELAYS
(F) 0342599 Control Relay (220V) (RL.4480237) (6) (G) 0342599 Control Relay (220V) (RL.4480237) (7) (H) 0460133 Transformer (EP.4481557) (8)
H
EATERS
(I) Electric Defrost Heaters (208V) (9)
0460114 (1) 2 Door Models 0460115 (1) 3 Door Models 0460116 (1) 4 Door Models 0460117 (1) 5 Door Models
(J) Drain Pan Heater (220V) Electric & Kool Gas (10)
0460110 (1) 2 Door Models 0460111 (1) 3 Door Models 0460112 (1) 4 Door Models 0460113 (1) 5 Door Models
Item Part # (Qty) Description Wiring Item #
H
EATERS (CONTINUED
)
(K) Koolgas Supplemental Heater (220V) – Plenum (11)
0460118 (1) 2 Door Models 0460119 (1) 3 Door Models 0460120 (1) 4 Door Models 0460121 (1) 5 Door Models
(L) Koolgas Supplemental Heater (220V) (12)
Drain Pan Bottom 0460122 (2) 2 Door Models 0460123 (2) 3 Door Models 0460124 (2) 4 Door Models 0460125 (2) 5 Door Models
L
AMPS, BALLASTS, LED FIXTURES AND POW ER SUPPLY
(M) 0489697 1 Lamp Ballast (BA.4481738)
0489698 2 Lamp Ballast (BA.4481596) 0424649 Export Ballast (BA.0424649)
(N) Standard Fluorescent Lamp
Replace with like fixtures
(O) Power Supply
(P) LED Fixture
Replace with like fixtures
NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
RLT (220V)
with
INNOVATOR
Doors
December 2009
Refer to I
NNOVATOR REACH-IN GLASS DOOR
I
NSTALLATION AND SERVICE MANUAL, P/N 0425683,
for Innovator door and frame replacement parts.
112200VV PPaarrttss LLiisstt iiss oonn PPaaggee 11..
Warning:
Terminal block NOT for
case-to-case
wire connection!
Loading...