Hussmann RLTI Innovator Specifications

L
D
E
B
H
M
J
I
K
Front
A
F
G
F
C
G
N
O
Merchandisers
®
Warning:
Terminal block NOT for
case-to-case
wire connection!
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision C updates parts on page 1 and lighting data on page 4.
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
A. Fan Assembly (1)
0477658
Standard Energy Efficient motor (MO.4410549
)
0315470 Fan Blade (FB.0315470)
B. 0331798 Standard Non-adjustable (2)
Defrost Thermostat (CT.4440256) C. Optional Adj. Refrigeration Thermostat (3) D. 0440423 Defrost Limit Thermostat (CT.4481089) (4)
E. 0446007 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater
Thermostat (CT.4440353)
R
ELAYS
F. 0342598 Anti-Sweat Control Relay (6)
(120V) (RL.4480238) G. 0342599 Fan Control Relay (208V) (7)
(RL.4480237)
H
EATERS
H. Electric Defrost Heaters (208V) (8)
0461938 (2) 2 Door Models (HE.4850354) 0461939 (2) 3 Door Models (HE.4850355) 0461940 (2) 4 Door Models (HE.4850356) 0461941 (2) 5 Door Models (HE.4850357)
I. Drain Pan Heater Electric & Kool Gas (120V) (9)
0508199
(2) 2 Door Models (HE.4851029)
0508200
(2) 3 Door Models (HE.4851030)
0508201
(2) 4 Door Models (HE.4850987)
0508202
(2) 5 Door Models (HE.4850988)
Item Part # Description Wiring Item #
H
EATERS (CONTINUED)
J. Kool Gas Supplemental Heater Plenum (120V) (10)
0452980 (2) 2 Door Models (HE.4850576) 0452981 (2) 3 Door Models (HE.4850577) 0452982 (2) 4 Door Models (HE.4850510) 0452983 (2) 5 Door Models (HE.4850578)
K. Kool Gas Supplemental Heater Bottom (120V) (11)
0452970 (2) 2 Door Models (HE.4850350) 0452971 (2) 3 Door Models (HE.4850506) 0452972 (2) 4 Door Models (HE.4850661) 0452973 (2) 5 Door Models (HE.4850507)
L
AMPS, BALLASTS, LED FIXTURES AND POWE R SUPPLY
Innovator Doors Standard
L. 0489697
1 Lamp Ballast (BA.4481738)
0489698
2 Lamp Ballast (BA.4481596)
M. Standard Fluorescent Lamp
Replace with like fixtures
N. Power Supply O. LED Fixture
Replace with like fixtures
NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available.
RLTI with INNOVATOR Doors
Technical Data Sheet
P/N 0468880_C
NSF
®
Certified
December 2009
Refer to INNOVATOR REACH-IN GLASS DOOR INSTALLATION AND SERVICE manual, P/N 0425683, for Innovator door and frame replacement parts..
P/N0468880C
RLTI
with Innovator Doors
Technical Data Sheet2 of 7
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Front
5-Door Shown
2, 3, 4, & 5 Door
A
71
5
/8
(1819)
42
1
/2
(1080)
79
1
/8
(2010)
Bumper
to
Bumper
Refrigeration
Outlets
Refrigeration Outlets
Rear Relay & Terminal Block Location
36
5
/8
(930)
81
(2058)
Handle
to
Handle
62 (1575)
5 (127)
Electrical Wireway
Bottom Front Support
48
(1219)
Skid/ External Base
2 3/4 (70)
6
(152)
Electrical Wireway
7
(178)
2
3
/8 (60)
2
3
/8 (60)
2 1/2 (64)
2 1/2 (64)
B
B
7
1
/2
(190)
Splashguard
Waste Outlet
26
1
/2
(673)
26
1
/2
(673)
125 3/8
(3185)
Door Swing
Door Swing
Front Relay & Terminal
Block Location
Dimensions shown as in. & (mm).
Serial Plate attached to top left front of each case.
2 Dr 3 Dr 4 Dr 5 Dr
General
(A) Case Length (without ends or partitions) 62 (1575) 92 1/2 (2350) 122 7/8 (3121) 153 3/8 (3896)
Maximum O/S dimension of case back to front 81 (2068) 81 (2068) 81 (2068) 81 (2068)
(Includes bumpers and handles)
Back of case to rear of splashguard 74 3/4 (1899) 74 3/4 (1899) 74 3/4 (1899) 74 3/4 (1899) Width of Skid rail 3 3/
4 (95) 3
3
/
4 (95) 3
3
/
4 (95) 3
3
/
4 (95)
Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152) Stub-up area between front skid rail and splashguard 6
3
/8 (161) 6 3/8 (161) 6 3/8 (161) 6 3/8 (161)
Electrical Service
Left hand end of case to the center of nearest knockout 2
3
/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Right hand end of case to the center of center knockout 56
3
/4 (1441) 87 1/4 (2216) 117 5/8 (2988) 148 1/8 (3762) Back O/S of case to center of front knockout 43 1/4 (1099) 43 1/4 (1099) 43 1/4 (1099) 43 1/4 (1099) Back O/S of case to center of rear knockout 10 3/8 (264) 10 3/8 (264) 10 3/8 (264) 10 3/8 (264)
* NOTE: Electrical Field Wiring Connection Point is at terminal. Front and rear are wired separately.
Waste Outlet
(B) Right end of case to center of waste outlet 23 7/8 (606) 54 1/4 (1378) 46 1/4 (1175) 76 5/8 (1946)
Back O/S of case to center of waste outlet 71 3/8 (1814) 71 3/8 (1814) 71 3/8 (1814) 71 3/8 (1814)
Water Seal
Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 drip piping 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case
Refrigeration Outlet
RH end of case to center of front refrigeration outlet 7 1/4 (184) 7 1/4 (184) 7 1/4 (184) 7 1/4 (184) RH end of case to center of rear refrigeration outlet 54 3/4 (1391) 85 1/4 (2166) 115 5/8 (2937) 146 1/8 (3712) Back O/S of case to center of front refrigeration outlet 43 1/4 (1099) 43 1/4 (1099) 43 1/4 (1099) 43 1/4 (1099) Back O/S of case to center of rear refrigeration outlet 35 1/8 (892) 35 1/8 (892) 35 1/8 (892) 35 1/8 (892) Outside bottom front supports from end of case 6 3/4 (170) 6 3/4 (170) 6 3/4 (170) 6 3/4 (170) Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610)
Distance between Center and Outside supports will vary
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
06-2009
RLTI Plan View
2, 3, 4, & 5 Door
Engineering Plan Views
REFRIGERATION DATA
Note: This data is based on store
temperature and humidity that does not exceed 75°F and 55% R.H.
FF IC
Discharge Air (°F) –5 –12
Evaporator (°F) –11 –19
Unit Sizing (°F) –14 –22
Btu/hr/door/side* FF IC
Parallel
1230 1298
Conventional
1252 1325
*Optional LED lighting reduces refrigeration load by 75 Btu/hr/door.
DEFROST DATA
FF IC
Frequency (hr) 24 24
Defrost Water
(lb/Dr/side/day) 1.2 1.2
(± 15% based on case configuration and
product loading).
E
LECTRIC
FF IC
Temp Term (°F) 54° 54°
Failsafe (minutes) 48 48
GAS
Duration (minutes) 22 22
O
FFTIME Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC
CI/CO (Temp °F)** –18°/ –34° –26°/ –45°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)**
Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge per Side (lb)***
2Dr 1.8 4Dr 3.6
3Dr 2.7 5Dr 4.6
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by each Standard End (in.) 2 Optional End with Window (in.) 1
1
/2
Optional Partition (in.) 1 1/2
Refrigeration data is PER SIDE.
P/N 0468880_C
Impact RLTI
With INNOVATOR Doors
Frozen Food & Ice Cream
7 1/2
(190)
10 3/8 (264)
RLTI
FAN
C O
I
L
67 3/4 (1721)
71 5/8 (1819)
75 7/8 (1927)
79 1/8 (2010)
20
(508)
25 7/8
(657)
22
(559)
63 5/8 (1616)
68 3/4
(1746)
7 1/8 (180)
C O
I
L
FAN
81 (2058)
42 1/2 (1080)
36 5/8 (930)
Refrigeration Outlets
6 1/8
(156)
11 3/8 (289)
Electrical Wireway
89
(2261)
86
(2184)
74 1/2
(1892) Frame
73 1/8
(1857)
Door
8 1/4
(210)
24 5/8
(625)
Dimensions shown as in. & (mm).
Tall Reach-in Island 2, 3, 4 and 5 Door Models INNOVATOR Doors Standard
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
3 of 7
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Electrical Data
2Dr 3Dr 4Dr 5Dr
Number of Fans – 25W 2 3 4 5
Amperes Watts
2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Evaporator Fan
120V 60Hz Standard Energy Efficient 1.65 2.5 3.3 4.1 125 188 250 313 220V 60Hz Export Energy Efficient 0.91 1.38 1.82 2.26 125 188 250 313
Anti-Sweat Heaters
120V 50/60Hz Doors 1.35 2.03 2.7 3.38 162 243 324 405 120V 50/60Hz Frames 0.96 1.43 1.92 2.4 115 172 230 288
220V 50/60Hz Doors - Export 0.74 1.10 1.47 1.84 162 243 324 405 220V 50/60Hz Frames - Export 0.52 0.78 1.05 1.31 115 172 230 288
Minimum Circuit Ampacity
120V 60Hz Standard 4.17 6.17 8.13 10.09 220V 60Hz Export 5.37 8.28 11.18 14.08
Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 220V 20 20 20 20
Defrost
Drain Heaters (Kool-Gas or Electric)
120V 50/60Hz Standard 1.00 1.50 2.00 2.50 120 180 240 300 220V 50/60Hz Export 0.50 0.75 1.00 1.25 110 165 220 275
Kool-Gas Supplemental Heaters
120V 50/60Hz Standard 4.30 6.78 9.18 11.58 516 814 1102 1390 220V 50/60Hz Export 2.35 3.70 5.01 6.32 472 744 1007 1270
Electric Defrost Heater
208V 50/60Hz Standard 7.70 11.50 15.4 19.2 1600 2400 3200 4000 220V 50/60Hz Export 6.70 10.00 13.3 16.6 1465 2200 2930 3660
Standard Vertical Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Innovator Doors Innovator or Innovator II
120V 50/60Hz Standard 1.50 2.00 2.5 3.00 180 240 300 360 220V 50/60Hz Export 0.84 1.12 1.40 1.68 185 246 308 370
Optional LED Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr
Hussmann EcoShine™ Energy Plus (120V) 0.30 0.45 0.60 0.75 36 54 72 90
Hussmann EcoShine™ Energy Plus [220V (Export)] 0.16 0.25 0.33 0.41 36 54 72 90
Hussmann EcoShine™ (120V) 0.45 0.68 0.90 1.13 54 81 108 135
Hussmann EcoShine™ [220V (Export)] 0.25 0.37 0.49 0.61 54 81 108 135
Hussmann Always*Bright™ (120V) 0.67 1.00 1.33 1.67 80 120 160 200
Hussmann Always*Bright™ [220V (Export)] 0.36 0.55 0.73 0.91 80 120 160 200
*Innovator or Innovator II
RLTI
with Innovator Doors
Technical Data Sheet4 of 7
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Hussmann recommends against frame heater cycling with
Innovator
doors to prevent door seals from freezing to the
frames and tearing.
Impact RLTI
With INNOVATOR Doors
Frozen Food & Ice Cream
ELECTRICAL DATA IS PER SIDE — TWO CIRCUITS REQUIRED PER CASE.
5 of 7P/N 0468880_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
5
Case Solid End
1 Dr 2 Dr 3 Dr 4 Dr 5 Dr (each)
lb (kg) NA (NA) 1667 (756) 2322 (1053) 2945 (1336) 3611 (1637) 120 (55)
5
Actual weights will vary according to optional kits included.
Product data is PER SIDE.
Impact RLTI
With INNOVATOR Doors
Frozen Food & Ice Cream
Product Data
Recommended Usable Cube
1
(Cu Ft/Dr) 24.95 ft3 /Dr (0.71 m3 /Dr)
ARI Total Display Area
2
(Sq Ft/Dr) 13.59 ft2/Dr (1.26 m2 /Dr)
Shelf Area 3(Sq Ft/Dr) 32.38 ft2/Dr (3.01 m2 /Dr)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (6) rows of 22-inch shelves.
Electric Defrost Sequence - Low Temperature
1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater.
2. If the Defrost Heater raises internal air temperature above 90°F, the Defrost Limit Thermostat (4) will open.
3. Temperature rise of the evaporator closes the Relay Control Thermostat (5) at about 35°F, energizing 120V A.S. Relay Coils (6). These relays’ contacts open the Frame and Door Heater Circuits, and prevent the Fan Circuit from energizing upon defrost termination.
4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan Relay Coil Circuits. The Drain Pan Heater goes off.
5. Temperature fall of the evaporator opens the Relay Control Thermostat (5) at about 20°F, de-energizing 120V A.S. Relay Coils (6). A.S. Relay Contacts close the Frame and Door Heater Circuits, and Fan Circuit.
Fan and Heater Circuits — Electric Defrost (standard)
Low Temperature
Wiring Diagram is per side — two circuits required per case.
Wiring Diagram is per side — two circuits required per case.
RLTI
with Innovator Doors
Technical Data Sheet6 of 7
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C
OR
120V POWER
OR
Switch
17
20
NEUTRAL
C
208V
Evaporator Fan
Relay Coil
1
3
R
R
Defrost Heater
R
5
4
BB
7
R
N.C.
7
8
8
Defrost Limit
208V
208V
1
2
3
4
6
O.O.R.
Defrost Termination
Thermostat
Refrigeration
Thermostat
(Optional)
Pink
2
3
}
To Condensing Unit
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
COM
N.O.
Rod Heater (Drain)
9
Y
Y
N.C.
7
7
1
3
W
B
Relay Control
25
Fan Relay
B
5
6
B
B
COM
N.C.
6
A.S. Relay
24
Door A.S. Heaters
Frame A.S. Heaters
21
22
2P
P
2P
P
12
11
10
120V POWER
16
13
Terminal Blocks in Raceway
Low Temperature with
Electric Defrost
20
21
22
26
17
1234
56 7
81011 1413 16
LIGHTS
(120V)
DEFROST HEATERS
(208V)
CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the
circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240.
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
Permanent Internal
Jumpers
R P
W
BRORRRRBKBKRRBKP2PBK BK ORBK 2P Y
14
26
C.O.R.
Removable External
Jumpers
DB
C.O.R.
2
Defrost Termination
Thermostat
FIELD WIRED
DB
NEUTRAL
Dark Blue
Refer to Innovator Reach-In
Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
C
6
120V
Fan Relay
N.C.
120V Fan
Relay Coil
6
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BL = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
7 of 7P/N 0468880_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Gas Defrost Sequence - Low Temperature
1. Defrost vapor enters evaporator causing a rise in temperature. At about 35°F the Control Relay Thermostat
(5) closes the
Fan Relay Coil and Control Relay Coil (6) circuit. The Coil opens the Fan, Door Heater, and Frame Heater circuits, while energizing the Drain Pan, Bottom, and Plenum Heaters
(9), (10) and (11).
2. If the Drain Pan Heater (9) raises internal air temperature above 90°F, the Heater Limit Thermostat (4) will open.
3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20°F, the Control
Relay Thermostat will open, de-energizing the Control Relay Coil and Fan Relay Coil
(7). Control and Fan Relay’s will
open the Drain Pan Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits.
Fan and Heater Circuits — Gas Defrost (optional)
Low Temperature
Wiring Diagram is per side — two circuits required per case.
Wiring Diagram is per side — two circuits required per case.
9
Permanent Internal
Jumpers
A.S. Relay
Coil
BR
Evaporator Fans
1
Fan Relay
COM
N.O.
Rod Heater (Drain)
Y
Y
N.C.
6
6
1
3
W
B
Relay Control
c
25
Fan Relay
F
B
5
6
B
B
COM
N.C.
6
A.S. Relay
24
Door A.S. Heaters
Frame A.S. Heaters
22
2P
2P
P
12
10
120V POWER
13
26
C.O.R.
P
OR
120V POWER
OR
Switch
NEUTRAL
17
20
Terminal Blocks in Raceway
Low Temperature with
Gas Defrost
202122
26
17
10 11 1413 16
LIGHTS
(120V)
Refrigeration
Thermostat
(Optional)
Pink
3
}
To Condensing Unit
24 2512
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
P
W
BROR
BK
P2PBK BK ORBK 2P Y
Removable External
Jumpers
16
6
Fan Relay
Coil
11
c
Defrost Limit
4
O.O.R.
14
21
NEUTRAL
Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683,
for Innovator door and frame replacement parts.
10
11
Koolgas Supplemental
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BL = Black
LB = Light Blue Pink = Pink BR =Brown Y =Yellow OR = Orange W = White
Loading...