Hussmann RLN Innovator 2 Specifications

K
E
F
C
G
B
I
A
J
D
H
L
M
RLN with INNOVATOR II
No Heat Doors
Technical Data Sheet
P/N 0463049_G
NSF
®
Certified
November 2009
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Warning:
Terminal block NOT for
case-to-case
wire connection!
Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Optional Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
B. 0474033 Standard Non-adjustable (2)
Defrost Thermostat (CT.4440726)
C. Optional Adjustable
Refrigeration Thermostat (3)
D. 0344662 Defrost Limit Thermostat (4)
(CT.4440261)
E. 0461814 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater Thermostat (CT.4481296)
RELAYS
F. 0342598 Anti-Sweat Control Relay (6)
(120V) (RL.4480238)
G. 0342599 Fan Control Relay (208V) (7)
(RL.4480237)
Refer to INNOVATOR REACH-IN GLASS DOOR INSTALLATION AND SERVICE manual, P/N 0425683,
for Innovator II door and frame replacement parts.
Item Part # (Qty) Description Wiring Item #
HEATERS
H. Electric Defrost Heaters – Front (208V) (8)
0441755 (1) 2 Door Models (HE.4850346) 0441756 (1) 3 Door Models (HE.4850337) 0441757 (1) 4 Door Models (HE.4850347) 0441758 (1) 5 Door Models (HE.4850323)
Electric Defrost Heaters — Rear (208V) (8) 0463891 (1) 2 Door Models (HE.4850358) 0463892 (1) 3 Door Models (HE.4850359) 0463893 (1) 4 Door Models (HE.4850360) 0463894 (1) 5 Door Models (HE.4850361)
I. Drain Pan Heater (Electric & Kool Gas) (9)
(120V) 0387036 (1) 2 Door Models (HE.4850239) 0387037 (1) 3 Door Models (HE.4850240) 0387038 (1) 4 Door Models (HE.4850241) 0387039 (1) 5 Door Models (HE.4850242)
LAMPS. BALLASTS, LED FIXTURES AND POWER SUPPLY
J. 0430329 1 Lamp Ballast (BA.4480341)
0430330 2 Lamp Ballast (BA.4480342) 0454319 3 Lamp Ballast (BA.4480601) 0424649 Export Ballast (BA.0424649)
K. Standard Fluorescent Lamp
Replace with like fixtures
L. 0499399 LED Power Supply (EP.4481668)
M. LED Fixture
Replace with like fixtures
©2009 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
NOTE: Revision G updates electrical data, Page 4.
P/N0463049G
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
RLN with Innovator II Doors Technical Data Sheet
2 of 7
26
1
/2
(673)
66
1
/4
(1683)
4
(102)
39
3
/4
(1010)
Front
5-Door Shown
6
(152)
30
5
/8
(778)
28
(711)
5
5
/8
(143)
37
5
/8
(956)
Refrig. Outlet
A
B
Electrical Wireway
Bottom Front Support
48
(1219)
Waste Outlet
Relay & Terminal
Block Location
Skid/ External Base
13/4
(44)
13/4
(44)
7
(178)
4
(102)
Splashguard
Dimensions shown as in. & (mm).
2 Dr 3 Dr 4 Dr 5 Dr
General
(A) Case Length (without ends or partitions) 62 (1575) 92 1/2 (2350) 122 7/8 (3121) 153 3/8 (3896)
Maximum O/S dimension of case back to front 39 3/4 (1010) 39 3/4 (1010) 39 3/4 (1010) 39 3/4 (1010)
(Includes bumper)
Back of case to rear of splashguard 35 3/8 (899) 35 3/8 (899) 35 3/8 (899) 35 3/8 (899) Width of Skidrail 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152) Stub-up area between front skidrail and splashguard 6 3/8 (1000) 6 3/8 (1000) 6 3/8 (1000) 6 3/8 (1000)
Electrical Service
RH end of case to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102)
(B) RH end of case to the center of LH knockout 58 (1473) 88 1/2 (2248) 118 7/8 (3019) 149 3/8 (3794)
Back O/S of case to center of knockout 37 5/8 (956) 37 5/8 (956) 37 5/8 (956) 37 5/8 (956)
* NOTE: Electrical Field Wiring Connection Point is at terminal.
Waste Outlet
(C) Right end of case to center of waste outlet 23 3/4 (603) 54 1/4 (1378) 46 1/4 (1175) 76 5/8 (1946)
Back O/S of case to center of waste outlet 34 5/8 (879) 34 5/8 (879) 34 5/8 (879) 34 5/8 (879)
Water Seal
Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) Outside diameter of drip piping 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet 5 3/
8 (137) 5
3
/
8 (137) 5
3
/
8 (137) 5
3
/
8 (137)
Back O/S of case to center of refrigeration outlet 28 (711) 28 (711) 28 (711) 28 (711)
(D) Outside bottom front supports from end of case 6
3
/
4 (170) 6
3
/
4 (170) 6
3
/
4 (170) 6
3
/
4 (170)
Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610)
Distance between Center and Outside supports will vary
06-2009
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Narrow Reach-In
2, 3, 4 & 5 Door
Engineering
Plan Views
RLN - RMN
Plan View
06-2009
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
FF IC Discharge Air (°F) –5 –12 Evaporator (°F) –9 –17 Unit Sizing (°F) –12 –20
Btu/hr/Door
FF IC Parallel
1195 1258
Conventional
1220 1310 †Optional LED lighting reduces refrigeration load by 100 Btu/hr/Door. Optional Energy Efficient Fan motors reduce refrigeration load by 109 Btu/hr/Door.
DEFROST DATA
FF IC Frequency (hr) 24 24 Defrost Water (lb/Dr/day) 1.2 1.2 (± 15% based on case configuration and
product loading.)
ELECTRIC FF IC
Temp Term (°F) 48° 48° Failsafe (minutes) 45 45
G
AS
Duration (minutes) 20 20
O
FFTIME
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC
CI/CO (Temp °F)* –18°/ –34° – 26°/ –45°
Indoor Unit Only, Pressure Defrost Termination (Temp °F)*
Not Recommended *Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge (lb)**
2Dr 1.8 3Dr 2.7 4Dr 3.6 5Dr 4.6
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by each
Standard End (in.) 2 Optional End with Window (in.) 1
1
/2
Optional Partition (in.) 1 1/2
3 of 7P/N 0463049_G
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
4
(121)
28 (711)
39 (1010)
37 (962)
30 (778)
2
(67)
82 1/4
(2089)
83
(2108)
1
/2
6
1
/4
(159)
13 1/8
(333)
Frame
3 1/2
(89)
Narrow Reach-in 2, 3, 4 and 5 Door Models INNOVATOR II Doors Standard
Dimensions shown as in. & (mm).
Impact RLN
With INNOVATOR II Doors
Frozen Food & Ice Cream
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Loading...