Hussmann RLNIE Technical Data Sheet

REAR
F
G
I
K
L
B
Serial Plate
J
D
K
C
Main Terminal Block
Terminal Block
Terminal Block
H
K
L
A
F
G
Terminal Block
B
A
B
M
F
G
P/N 0444704_D
®
Warning:
Terminal block
NOT for
case-to-case
wire connection!
RLNIE
with INNOVATOR Doors
Technical Data Sheet
P/N 0444704_D
NSF
®
Certified
June 2007
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Optional Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
B. 0474033 Standard Non-adjustable (2)
Defrost Thermostat (CT.4440726)
C. Optional Adjustable
Refrigeration Thermostat (3)
D. 0344662 Defrost Limit Thermostat (4)
(CT.4440261)
E. 0461814 Relay Control Thermostat or (5)
Fan and Anti-sweat Heater Thermostat (CT.4481296)
RELAYS
F. 0342598 Anti-Sweat Control Relay (6)
(120V) (RL.4480238)
G. 0342599 Fan Control Relay (208V) (7)
(RL.4480237)
Item Part # Description Wiring Item #
HEATERS
H. 0441755 Electric Defrost Heater (8)
Front [2] (208V) (HE.4850346)
H. 0463891 Electric Defrost Heater (8)
Rear [2] (208V) (HE.4850358)
H. 0444685 Electric Defrost Heater (8)
End [2] (208V) (HE.4850502)
I. 0387037 Drain Pan Heater [2] (9)
Electric & Kool Gas (120V) (HE.4850240)
J 0444712 Flue Reheater (120V) (10)
(HE.4850573)
LAMPS AND BALLASTS
K. 0430329 1 Lamp Electronic Ballast (11)
(BA.4480341)
L. 0430330 2 Lamp Electronic Ballast (11)
(BA.4480342)
0454319 3 Lamp Electronic Ballast (11)
(BA.4480601)
M. Fluorescent Lamp (12)
Replace with like fixtures
Note: Changed items have bar in margin.
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Merchandisers
RLNIE with Innovator Doors Technical Data Sheet
2 of 10
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
RLNIE
General
Case Length 99
3
/4 (2530) Maximum O/S dimension of case back to front (Includes bumpers) 72 3/8 (1837) Width of skid rail 4 1/
2 (114)
Width of Bottom Support 6 (152) Stub-up area between front skid rail and splashguard 6
3
/8 (162)
Electrical Service*
RH end of case to the center of nearest knockout 4 (102) RH end of case to the center of LH knockout 88 3/8 (2246) Back O/S of case to center of knockout (Electrical Field Wiring Connection Point is at terminal.) 70 1/8 (1782)
Waste Outlet
RH end of case to center of waste outlet in back of case 38 1/8 (969) RH end of case to center of waste outlet in front of case 54 1/4 (1378) Back O/S of case to center of waste outlet 63 1/8 (1604)
Water Seal
Edge of water seal to center of waste outlet 11 (279) Outside diameter of drip piping 1 1/4 (32)
Field installed water seal outlets, tees, and connectors are shipped with case.
Refrigeration Outlet
RH end of case to center of refrigeration outlet 5 3/8 (137) Back O/S of case to center of refrigeration outlet 60 5/8 (1541) Outside bottom front supports from end of case 6 3/4 (171) Distance between centerlines of front supports 48 (1219)
Engineering
Plan Views
Reach-in
Narrow Island
Unitized End Case
Dimensions shown as in. & (mm).
6-2003
Relay & Terminal Block Location
Relay & Terminal Block Location
Electrical Wireway
(152)
99 3/4
(2530)
Electrical Wireway
6
Electrical Wireway
FRONT OF CASE
88 3/8
(2246)
Waste Outlet
48
(1219)
38 1/8
(969)
Water Seal
(See Note**)
Refrigeration Outlet
9 1/8
(232)
60 5/8
(1541)
63 1/8
(1604)
5 5/8
(142)
70 1/8
(1782)
72 3/8
(1837)
Waste Outlet
Main Field Connection
Electrical Terminal Block
Relay & Terminal Block Location
REAR OF CASE
54 1/4
(1378)
3 (76)
4 (102)
3 of 10P/N 0444704_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
FF IC
Discharge Air (°F) 0 –11
Evaporator (°F) –11 –19
Unit Sizing (°F) –14 –22
Btu/hr/case FF IC
Parallel
9,500 9,800
Conventional
9,700 10,000
DEFROST DATA
FF IC
Frequency (hr) 24 24
Defrost Water (lb/day) 8.6 8.6
(± 15% based on case configuration and
product loading).
E
LECTRIC
FF IC Temp Term (°F) 48 48 Failsafe (minutes) 45 45
GAS
Duration (minutes) 20 20
OFFTIME Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
FF IC
CI/CO (Temp °F)* –18/–34 –26/–45
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.) 1 1/4
Liquid Line (in.)
5
/8
Suction Line (in.) 1 1/8
Estimated Charge (lb/case)** RLNIE 5.4
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length added to Lineup by: Each Standard End (in.) 2 Optional End with Window (in.) 1
1
/
2
Insulated Partition (in.) 1 1/
2
Impact RLNIE
Frozen Food & Ice Cream
Dimensions shown as in. & (mm).
Reach-in Narrow Island, End and Center Unitized
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements.
83 1/2
(2120)
82 3/8
(2091)
72 (1835)
70 (1780)
67 (1724)
63 (1603)
60 (1537)
11
(281)
4
(121)
9
(232)