Hussmann RI2N Specifications

®
RI2N
Technical Data Sheet
P/N 0492430_C
NSF
Certified
April 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
8 Ft, 10 Ft & 12 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0142780 Fan Blade (FB.0142780)
embossing toward motor
12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0142780 Fan Blade (FB.0142780)
embossing toward motor
B. Optional Adjustable Refrigeration Thermostat (2)
0448347 (CT.4481631)
Item Part # Description Wiring Item #
HEATERS
C. Anti-Sweat Heater (3)
0487118 8 ft & 10 ft (HE.4850668) 0491966 12 ft (HE.4850834)
L
AMPS AND BALLASTS
D. Ballast, Electronic (4)
0355398 3 Lamps (BA.4480118) 0355716 2 Lamps (BA.0355716) 0447740 (BA.4481278)
E. Fluorescent Lamp (5)
Replace with like fixtures
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision C adds energy efficient fan Btu note on page 3.
P/N0492430C
E
C
E
B
D
A
Serial Plate
2 of 7
RI2N Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
8 ft 10 ft 12 ft
General
(A) Overall Case Length 96 (2438) 120 (3048) 144 (3658) (B) Base Length 77 (1956) 101 7/8 (2588) 125 (3176)
Maximum O/S dimension of case back to front
(includes bumper) 60 (1524) 60 (1524) 60 (1524) Front of splashguard to O/S edge of front base rail 1 5/8 (41) 1 5/8 (41) 1 5/8 (41) Front of case to O/S edge of front base rail 13 1/
8 (333) 13
1
/
8 (333) 13
1
/
8 (333)
Back of case to O/S edge of front base rail 58
7
/8 (1495) 58 7/8 (1495) 58 7/8 (1495)
Width of base rail 1 7/8 (48) 1 7/8 (48) 1 7/8 (48)
(D) Length of Canopy 66
1
/8 (1680) 66 1/8 (1680) 90 1/8 (2289)
Width of Canopy 18
1
/8 (460) 18 1/8 (460) 18 1/8 (460)
Electrical Service (Electrical Field Wiring connection point)
Center of Electrical service to O/S edge of front base rail 47 (1194) 47 (1194) 47 (1194) Left end of case to center of knockout 27 (686) 27 (686) 27 (686) Right end of case to center of knockout 69 (1753) 93 (2362) 117 (2972)
Waste Outlets
(C) LH End of case to the center of waste outlet 48 (1219) 78 (1981) 102 (2591)
Center of front waste outlet to outside of front base rail 8 7/8 (225) 8 7/8 (225) 8 7/8 (225) Center of back waste outlet to outside of front base rail 40 1/8 (1019) 40 1/8 (1019) 40 1/8 (1019) Schedule 40 PVC drip pipe 1
1
/2 (38) 1 1/2 (38) 1 1/2 (38)
Refrigeration Outlet
LH end of case to center of refrigeration outlet 22 (559) 22 (559) 22 (559) RH end of case to center of refrigeration outlet 74 (1880) 98 (2489) 122 (3099)
Engineering
Plan Views
08-2009
Front
Dimensions shown as inches and (mm).
RI2N Island
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
Serial
27
(686)
22
(559)
C
Field Connection Electrical Box
A
Plate
47
(1194)
5 1/2
(140)
7
(178)
26 1/2
(673)
9 1/2
(241)
Refrigeration Outlets
Canopy
B
D
Waste Outlets
18 1/8
(460)
(1524)
31 1/4
(794)
14 3/8
(365)
60
3 of 7P/N 0492430_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
RI2N
Discharge Air (°F) 27
Evaporator (°F) 20
Unit Sizing (°F) 18
Btu/hr/ft
L
IT & UNLIT
SHELVES
RI2N
Parallel 1444
Conventional 1575
Optional energy efficient motors reduce the
refrigeration load by 55 Btu/hr/ft.
DEFROST DATA
RI2N
Frequency (hr) 4
Defrost Water (lb/ft/day) 10
(± 15% based on case configuration and prod-
uct loading).
O
FFTIME
RI2N
Time Terminated (minutes) 20
E
LECTRIC OR G
AS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
RI2N
CI/CO* 14°F / 4°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*
Use a Temperature Pressure Chart to deter-
mine PSIG conversions.
Estimated Charge ** RI2N
8 ft 1.7 lb 27 oz 0.8 kg
10 ft 2.1 lb 34 oz 1.0 kg
12 ft 2.5 lb 40 oz 1.1 kg
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by approxi­mately half a pound.
Multi-deck Island, 3 Display Levels, Narrow Footprint
RI2N
RI2N
Delicatessen
Load Limit Profile
Air flow between the shelves, from the Center Air Discharge (CAD) to the return, must be maintained at all times for optimum operating efficiency and to prolong product shelf life. At no time should merchandisers be stocked beyond the load limits indicated.
Cases may not function properly if they are loaded above load limits.
NSF®Certification
This merchandiser is manufactured to meet ANSI/NSF
®
(National Sanitation
Foundation) Standard #7 requirements for construction, materials & cleanability.
1
18
/8
(460)
8 (203)
Standard Height Plex
and Product Stop
7
5
/8 (149)
1
3
/4 (83)
23
5
(140)
(607)
1
/2
1
21
/2 (546)
3 (76)
(305)
21 (533)
7
/8
49 (1245)
60 (1524)
12
6 (152)
Optional High Plex
and Product Stop
7
9
/8 (251)
27
(689)
5
(140)
3
55
/4
(1416)
1
/8
1
/2
CAD
Load Limit
Optional Shelves
Optional High Plex with 6 in. (152 mm) Product Depth
Load Limit
RI2N
4 of 7
RI2N Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
RI2N
Delicatessen
Electrical Data
8 ft 10 ft 12 ft
Number of Fans – 12W 4 6 8
Amperes Watts
8 ft 10 ft 12 ft 8 ft 10 ft 12 ft
Evaporator Fan
120V 60Hz Standard 2.60 3.90 5.20 200 300 400
120V 50Hz Standard 3.00 4.50 6.00 228 342 456
230V 60Hz Export NA NA NA NA NA NA
230V 50Hz Export NA NA NA NA NA NA
120V 60Hz Energy Efficient 1.20 1.80 2.40 72 108 144
230V 60Hz Energy Efficient NA NA NA NA NA NA
Anti-sweat Heaters
120V 50/60Hz Standard 0.70 0.70 0.90 84 84 108
230V 50/60Hz Export NA NA NA NA NA NA
Minimum Circuit Ampacity (MCA)
120V 60Hz Standard 3.97 5.27 6.90
120V 50Hz Standard 3.81 5.31 6.98
230V 60Hz Export NA NA NA
230V 50Hz Export NA NA NA
120V 60Hz Energy Efficient 2.01 2.61 3.38
230V 60Hz Energy Efficient NA NA NA
Maximum Over Current Protection 120V 20 20 20
Maximum Over Current Protection 230V NA NA NA
Standard Lighting
1 Row Canopy 0.49 0.49 0.98 59 59 118
Optional Lighting
1 Row of Ledge 1.67 2.00 2.33 200 240 280
Optional Shelf Lighting
1 Row of Shelves 0.82 0.82 1.12 98 98 134
2 Rows of Shelves 1.63 1.63 2.23 196 196 268
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
does not
5 of 7P/N 0492430_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case
8 ft 10 ft 12 ft End
lb (kg) 1100 (499) 1200 (544) 1300 (590) NA
4
Actual weights will vary according to optional kits included.
Product Data
RI2N8
Recommended Usable Cube
1
(Cu Ft/Case) 29.62 ft3 /case (0.84 m3/case)
AHRI Total Display Area
2
(Sq Ft/Case) 35.82 ft2 /case (3.33 m2 /case)
Shelf Area 3 (Sq Ft/Case) 54.64 ft2 /case (5.08 m2 /case)
RI2N10
Recommended Usable Cube
1
(Cu Ft/Case) 37.02 ft3 /case (1.05 m3/case)
AHRI Total Display Area
2
(Sq Ft/Case) 44.78 ft2 /case (4.16 m2 /case)
Shelf Area 3 (Sq Ft/Case) 68.30 ft2 /case (6.35 m2 /case)
RI2N12
Recommended Usable Cube
1
(Cu Ft/Case) 44.42 ft3 /case (1.26 m3/case)
AHRI Total Display Area
2
(Sq Ft/Case) 53.34 ft2 /case (4.96 m2 /case)
Shelf Area 3 (Sq Ft/Case) 81.96 ft2 /case (7.61 m2 /case)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume / Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2] / Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product
Reference Guide. The standard shelf complement for this model is (1) row of 8-inch shelf, (1) row of 12-inch shelf.
RI2N
Delicatessen
6 of 7
RI2N Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Fan Wiring Offtime Defrost
4, 6 & 8 Fans
8 ft 10 ft 12 ft
120V POWER
BROWN BAND
BROWN BAND
120V NEUTRAL
BROWN BAND
1
Fans
BROWN BAND
1
Anti-sweat Heaters
3
Refrigeration Thermostat
2
Light Blue
All components must have mechanical ground, and the merchandiser must be grounded.
= 120VPOWER
To Condensing
}
Unit
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V NEUTRAL = FIELD GROUND
WARNING
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
= CASE GROUND
7 of 7P/N 0492430_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ORANGE OR TAN BAND
Light Circuits
120V
N
EUTRAL
120V
P
OWER
Light
Switch
G
Lighted Shelf Wiring
W
B
G
B
4
BL
G G G
W
4
BL
G G G
W
G
B
4
BL
G G G
BL
R
5
R
5
R
5
BL BLR R
BL
BL BLR RR
BL
BL BLR RR
BL
R
5
BL
5
BL
5
5
5
5
Typical Shelf Ballast Wiring
Maximum lamps per ballast is three (3). Different shelf configurations and different case lengths will have more shelf ballasts.
Optional Ledge Light Circuit
W
G
B
All components must have mechanical ground, and the merchandiser must be grounded.