RI1
Technical Data Sheet
P/N 0492428_D
NSF
®
Certified
April 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
8 Ft, 12 Ft, 14 Ft & 16 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0376413 Fan Blade (FB.0376413)
embossing toward motor
12W Energy Efficient Fan Assembly (1)
0477655 Fan Motor, Evaporator
(MO.4410546)
0376413 Fan Blade (FB.0376413)
embossing toward motor
B. Optional Adjustable Refrigeration Thermostat (2)
0448347 (CT.4481631)
Item Part # Description Wiring Item #
H
EATERS
C. 0447688 Anti-Sweat Heater (3)
(HE.4850682)
L
AMPS AND BALLASTS
D. 0447683 Ballast, Electronic (4)
2 Lamps (BA.4440811)
E. Fluorescent Lamp (5)
Replace with like fixtures
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Note: Revision D updates cover graphics and adds energy efficient fan Btu note on page 3.
B
D
A
E
C
Serial Plate

8 ft 12 ft 14 ft 16 ft
General
(A) Overall Case Length 96 (2438) 144 (3658) 168 (4267) 192 (4877)
(B) Base Length 77 (1956) 125 (3176) 149 (3786) 173 (4394)
Maximum O/S dimension of case back to front (includes bumper) 72 (1829) 72 (1829) 72 (1829) 72 (1829)
Front of splashguard to O/S edge of front base rail 1
5
/8 (41) 1 5/8 (41) 1 5/8 (41) 1 5/8 (41)
Front of case to O/S edge of front base rail 13
1
/8 (333) 13 1/8 (333) 13 1/8 (333) 13 1/8 (333)
Back of case to O/S edge of front base rail 58
7
/8 (1495) 58 7/8 (1495) 58 7/8 (1495) 58 7/8 (1495)
Width of base rail 1
7
/8 (48) 1 7/8 (48) 1 7/8 (48) 1 7/8 (48)
(D) Length of Canopy 61
5
/8 (1565) 85 5/8 (2175) 109 5/8 (2784) 133 5/8 (3394)
Width of Canopy 13
5
/8 (346) 13 5/8 (346) 13 5/8 (346) 13 5/8 (346)
Electrical Service (Electrical Field Wiring connection point)
Center of Electrical service to O/S edge of front base rail 47 (1194) 47 (1194) 47 (1194) 47 (1194)
Left end of case to center of field connection box 27 (686) 27 (686) 27 (686) 27 (686)
Right end of case to center of field connection box 69 (1753) 117 (2972) 141 (3581) 165 (4191)
Waste Outlets
(C) LH End of case to the center of waste outlet 48 (1219) 102 (2591) 84 (2134) 96 (2438)
Center of front waste outlet to outside of front base 8
7
/8 (225) 8 7/8 (225) 8 7/8 (225) 8 7/8 (225)
Center of back waste outlet to outside of front base 40
1
/8 (1019) 40 1/8 (1019) 40 1/8 (1019) 40 1/8 (1019)
Schedule 40 PVC drip pipe 1
1
/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
Refrigeration Outlet
LH end of case to center of refrigeration outlet 22 (559) 22 (559) 22 (559) 22 (559)
RH end of case to center of refrigeration outlet 74 (1880) 122 (3099) 146 (3708) 170 (4318)
2 of 7
RI1 Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
RI1 Island
Engineering
Plan Views
08-2009
Front
Dimensions shown as inches and (mm).
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
A
C
Serial
Plate
7
(178)
47
(1194)
321/2
(826)
27
(686)
22
(559)
Field Connection
Electrical Box
Refrigeration
Outlets
Canopy
Waste
Outlets
13 5/8
(348)
72
(1829)
31 1/4
(794)
111/2
(292)
D
91/2
(241)
B
20 3/8
(518)

3 of 7P/N 0492428_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store tempera-
ture and humidity that does not exceed
75°F and 55% R.H.
RI1
Discharge Air (°F) 27
Evaporator (°F) 15
Unit Sizing (°F) 13
Btu/hr/ft
‡
RI1
Parallel 1260
Conventional 1375
‡
Optional energy efficient motors reduce the
refrigeration load by 55 Btu/hr/ft.
DEFROST DATA
RI1
Frequency (hr) 4
Defrost Water (lb/ft/day) 9
(± 15% based on case configuration and
product loading).
O
FFTIME
RI1
Time Terminated (minutes) 20
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
RI1
CI/CO* 8°F / –2°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge ** RI1
8 ft 1.7 lb 27 oz 0.8 kg
12 ft 2.5 lb 40 oz 1.1 kg
14 ft 3.1 lb 50 oz 1.4 kg
16 ft 3.7 lb 59 oz 1.7 kg
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Single Deck Island, 1 Display Level
RI1
RI1
Delicatessen
Load Limit Profile
Air flow between the shelves, from the Center Air Discharge (CAD) to the return, must be
maintained at all times for optimum operating efficiency and to prolong product shelf life.
At no time should merchandisers be stocked beyond the load limits indicated.
Cases may not function properly if they are loaded above load limits.
NSF®Certification
This merchandiser is manufactured to meet ANSI/NSF
®
(National Sanitation
Foundation) Standard #7 requirements for construction, materials & cleanability.
Standard Height Plex
and Product Stop
3 (76)
5
3
7
/8 (149)
1
/4 (83)
23
(607)
7
/8
27 (686)
13
(346)
5
/8
4 (102)
10
1
/8 (260)
Optional High Plex
and Product Stop
6 (152)
9
7
/8 (251)
44
(1127)
1
27
/8
(689)
3
/8
11
(292)
1
/2
49 (1245)
11
(292)
1
/2
72 (1829)
Optional High Plex
3 in. Space Required
CAD
Load Limit Load Limit
with 6 in. (152 mm)
Product Depth
RI1

4 of 7
RI1 Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
RI1
Delicatessen
Electrical Data
8 ft 12 ft 14 ft 16 ft
Number of Fans – 12W 4 8 10 12
Amperes Watts
8 ft 12 ft 14 ft 16 ft 8 ft 12 ft 14 ft 16 ft
Evaporator Fan
120V 60Hz Standard 2.60 5.20 6.50 7.80 200 400 500 600
120V 50Hz Standard 3.00 6.00 7.50 9.00 228 456 570 684
230V 60Hz Export NA NA NA NA NA NA NA NA
230V 50Hz Export NA NA NA NA NA NA NA NA
120V 60Hz Energy Efficient 1.20 2.40 3.00 3.60 72 144 180 216
230V 60Hz Energy Efficient NA NA NA NA NA NA NA NA
Anti-sweat Heaters †
120V 50/60Hz Standard 1.00 1.33 1.67 2.00 120 160 200 240
230V 50/60Hz Export NA NA NA NA NA NA NA NA
Minimum Circuit Ampacity (MCA)
†
120V 60Hz Standard 3.80 6.73 8.37 10.00
120V 50Hz Standard 3.72 6.90 8.57 10.24
230V 60Hz Export NA NA NA NA
230V 50Hz Export NA NA NA NA
120V 60Hz Energy Efficient 1.92 3.30 4.07 4.84
230V 60Hz Energy Efficient NA NA NA NA
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 230V NA NA NA NA
Standard Lighting
1 Row Canopy 0.80 1.20 1.60 2.00 96 144 192 240
Optional Lighting
1 Row of Ledge 1.67 2.33 2.67 3.00 200 280 320 360
Optional Shelf Lighting
None
115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting

5 of 7P/N 0492428_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
ESTIMATED SHIPPING WEIGHT
4
Case
8 ft 12 ft 14 ft 16 ft End
lb (kg) 1100 (499) 1400 (635) 1500 (680) 1600 (726) NA
4
Actual weights will vary according to optional kits included.
Product Data
RI18
Recommended Usable Cube 1 (Cu Ft/Case) 18.00 ft3 /case (0.51 m3/case)
AHRI Total Display Area 2 (Sq Ft/Case) 34.02 ft2 /case ( 3.16 m2 /case)
Shelf Area 3(Sq Ft/Case) 36.00 ft2 /case (3.34 m2 /case)
RI112
Recommended Usable Cube 1 (Cu Ft/Case) 27.00 ft3 /case (0.76 m3/case)
AHRI Total Display Area 2 (Sq Ft/Case) 51.04 ft2 /case (4.74 m2 /case)
Shelf Area 3(Sq Ft/Case) 54.00 ft2 /case ( 5.02 m2 /case)
RI114
Recommended Usable Cube 1 (Cu Ft/Case) 31.50 ft3 /case (0.89 m3/case)
AHRI Total Display Area 2 (Sq Ft/Case) 59.54 ft2 /case (5.53 m2 /case)
Shelf Area 3(Sq Ft/Case) 63.00 ft2 /case (5.85 m2 /case)
RI116
Recommended Usable Cube 1 (Cu Ft/Case) 36.00 ft3 /case (1.02 m3/case)
AHRI Total Display Area 2 (Sq Ft/Case) 68.05 ft2 /case (6.32m2 /case)
Shelf Area 3(Sq Ft/Case) 72.00 ft2 /case (6.69 m2 /case)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume / Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2] / Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product
Reference Guide. The standard shelf complement for this model is none.
RI1
Delicatessen

6 of 7
RI1 Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Fan Wiring
Offtime Defrost
4, 8, 10 & 12 Fans
8 ft
12 ft
14 ft
16 ft
120V P
OWER
BROWN BAND
BROWN BAND
120V NEUTRAL
BROWN BAND
1
Fans
BROWN BAND
1
Anti-sweat Heater
3
Refrigeration Thermostat
2
Light Blue
All components must have mechanical ground, and the merchandiser must be grounded.
= 120VP
To
Condensing
}
Unit
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
OWER = 120V NEUTRAL = FIELD GROUND
WARNING
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
= CASE GROUND

7 of 7P/N 0492428_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
Light
Switch
B
W
G
Optional Ledge Light Circuit
W
G
B
4
BL R BL R BL R
G
BL
R
5
G G
BL
5
5
4
BL R BL R BL R
G G G
BL
R
5
BL
5
5
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120VPOWER
= 120V NEUTRAL = FIELD GROUND
= CASE GROUND