![](/html/ee/eea3/eea37c54dc53ce18b65dfdbc42a5166d6fc22b49d3b045f8c5b2cc6aba229201/bg1.png)
7
Specialty Products
RGPSM
These merchandi s ers a re manufactured to meet ANSI/Na tional Sanitat i on
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
ETL Listed
40427
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 30
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft*
Parallel 850
Conventional 978
Parallel 175
Conventional 201
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
Frequency Hrs 8
OFFTIME
Temp Term °F 54
Failsafe Minutes 40
ELECTRIC or GAS Not Recommended
Merchandiser Drip Pipe (in.) 1 ½*
Merchandiser Liquid Line (in.) 3/8*
Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
4ft 1.2
5ft 1.5
6ft 1.8
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
GLYCOL REQUIREMENTS
GPM PSI
4ft 1.2 0.9
6ft 1.8 1.9
8ft 2.4 3.3
10ft 3.0 4.8
12ft 3.6 6.7
RGPSM
Technical Data Sheet
Front
Rear Storage
DEFROST DATA
PHYSICAL DATA
Rev C
ETL Sanitation
40427
1 of 7
![](/html/ee/eea3/eea37c54dc53ce18b65dfdbc42a5166d6fc22b49d3b045f8c5b2cc6aba229201/bg2.png)
7
Engineering
Plan View
Specialty Products
RGPSM
RGPSM
Technical Data Sheet
Rev C
RGPSM
Self Contained 6’ W2600005
6' W2600007
10' W2600008
12' W2600004
45 OS W2600006
2 of 7