9
Specialty Products
RGDC
RGDC
Technical Data Sheet
Rev C
These merchandisers are manufactu red t o meet ANSI/N ational Sanitat i on
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
ETL Listed
40427
ETL Sanitation
40427
1 of 9

9
REFRIGERATION DATA 24” Depth
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 28
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft*
Parallel 1700
Conventional 1955
GLYCOL REQUIREMENTS
GPM PSI
NA NA
NA NA
NA NA
Btu/hr/ft*
Parallel 1800
Conventional 2070
GLYCOL REQUIREMENTS
GPM PSI
NA NA
NA NA
NA NA
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
Frequency Hrs 6
OFFTIME
Temp Term °F 54
Failsafe Minutes 20
ELECTRIC or GAS Not Recommended
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
72” High
83” High
DEFROST DATA
Specialty Products
RGDC
RGDC
Technical Data Sheet
REFRIGERATION DATA 30” Depth
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 28
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft*
Parallel 1900
Conventional 2185
GLYCOL REQUIREMENTS
GPM PSI
NA NA
NA NA
NA NA
Btu/hr/ft*
Parallel 2000
Conventional 2300
GLYCOL REQUIREMENTS
GPM PSI
NA NA
NA NA
NA NA
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
Frequency Hrs 6
OFFTIME
Temp Term °F 54
Failsafe Minutes 20
ELECTRIC or GAS Not Recommended
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
72” High
83” High
DEFROST DATA
Rev C
2 of 9