Hussmann RCD Specifications

6
Specialty Products
RCD
Technical Data Sheet
RCD
Discharge Air (F) 30 Evaporator (F) 20
Note: Not recommended to control temp by regulating coil temp allow t-stat to cycle and control temp.
Btu/hr/ft* Parallel 820
Conventional 943
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
Frequency Hrs 8
OFFTIME Temp Term °F 54 Failsafe Minutes 40
ELECTRIC or GAS Not Recommended
Merchandiser Drip Pipe (in.) 1 ½* Merchandiser Liquid Line (in.) 3/8* Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
40427
ETL Listed
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual refrigerant charge may vary by approximately half a pound.
GPM PSI 4ft 1.2 1.2 6ft 1.7 2.6 8ft 2.3 4.4 10ft 3.5 9.4
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75F and 55% R.H.
DEFROST DATA
PHYSICAL DATA
4ft 1.2 5ft 1.5 6ft 1.8
GLYCOL REQUIREMENTS
ETL Sanitation
40427
1 of 6
Rev B
6
Engineering
Cut & Plan View
RCD
Specialty Products
RCD
RCD
Technical Data Sheet
Rev B
2 of 6
Loading...
+ 4 hidden pages