These merchandisers are manufactu red t o meet ANSI/N ational Sanitat i on
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
ETL Listed
40427
ETL Sanitation
40427
R3HV-WD-D
Technical Data Sheet
Rev B
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 24
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft*
Parallel 750
Conventional 863
Parallel 580
Conventional 667
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
Frequency Hrs 6
OFFTIME
Temp Term °F 54
Failsafe Minutes 40
ELECTRIC or GAS Not Recommended
Merchandiser Drip Pipe (in.) 1 ½*
Merchandiser Glycol Pipe (in.) 7/8*
Merchandiser Liquid Line (in.) 3/8*
Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
4ft 1.2
5ft 1.5
6ft 1.8
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
GLYCOL REQUIREMENTS
GPM PSI
NA NA
NA NA
NA NA
Front
Top
DEFROST DATA
PHYSICAL DATA