Hussmann R3HV- MF Specifications

7
Specialty Products
R3HV-M/F
These merchandisers are manufactu red t o meet ANSI/N ational Sanitat i on Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
ETL Listed
40427
R3HV-M/F
Technical Data Sheet
Rev C
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 24 Evaporator (F) 20
Note: Not recommended to control temp by regulating coil temp allow t-stat to cycle and control temp.
Btu/hr/ft* Parallel 650
Conventional 748
Parallel 565
Conventional 650
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
Frequency Hrs 6
OFFTIME Temp Term °F 54 Failsafe Minutes 40
ELECTRIC or GAS Not Recommended
Merchandiser Drip Pipe (in.) 1 ½* Merchandiser Liquid Line (in.) 3/8* Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
4ft 1.2 5ft 1.5 6ft 1.8
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual refrigerant charge may vary by approximately half a pound.
GLYCOL REQUIREMENTS
GPM PSI NA NA NA NA NA NA
Front
Top
DEFROST DATA
PHYSICAL DATA
ETL Sanitation
40427
1 of 7
7
Specialty Products
R3HV-M/F
Engineering
CROSS SECTION
R3HV-M/F
Technical Data Sheet
Rev C
2 of 7
7
Specialty Products
R3HV-M/F
Engineering
Plan View
R3HV-M/F
Technical Data Sheet
Rev C
R3M/F - HV HIGH VOLUME
4' 1H23786 6' 1H23787 8' 1H23788
12' 1H23789
3 of 7
Loading...
+ 4 hidden pages