APPENDIX A. – Temperature Guidelines ............................................................ 51
APPENDIX B. – Application Recommendations.................................................. 51
APPENDIX C. – Field Recommendations -......................................................... 52
APPENDIX D. – Recommendations to user ....................................................... 53
IGFP-R3H, R3HTO, R3HA, R3Combo-0208
THIS BOOKLET CONTAINS INFORMATION ON:
R3H: Hot Service/Refrigerated Self-Service Case
R3HA / R3HATO: Circulating Hot Air Case
R3 Combo: any combination of Hot and/or Cold Service with
Self Service Refrigerated Front
SHIPPING DAMAGE
All equipment should be thoroughly examined for shipping damage before and during unloading.
This equipment has been carefully inspected at our factory and the carrier has assumed responsibility for safe
arrival. If damaged, either apparent or concealed, claim must
be made to the carrier.
APPARENT LOSS OR DAMAGE
If there is an obvious loss or damage, it must be noted on
the freight bill or express receipt and signed by the carrier’s
agent; otherwise, carrier may refuse claim. The carrier will
supply necessary claim forms.
CONCEALED LOSS OR DAMAGE
When loss or damage is not apparent until after equipment
is uncrated, a claim for concealed damage is made. Make
request in writing to carrier for inspection within 15 days,
and retain all packaging. The carrier will supply inspection
report and required claim forms.
SHORTAGES
Check your shipment for any possible shortages of material. If a shortage should exist and is found to be the responsibility of Hussmann Chino, notify Hussmann Chino. I f
such a shortage involves the carrier, notify the carrier imme-diately, and request an inspection. Hussmann Chino will
acknowledge shortages within ten days from receipt of
equipment.
HUSSMANN CHINO PRODUCT CONTROL
The serial number and shipping date of all equipment has
been recorded in Hussmann’s files for warranty and replacement part purposes. All correspondence pertaining
to warranty or parts ordering must include the serial number of each piece of equipment involved, in order to provide the customer with the correct parts.
Keep this booklet with the case at all times for future reference.
/Chino
A publication of
Hussmann® Chino
13770 Ramona Avenue • Chino, California 91710
(909) 628-8942 FAX
(909) 590-4910
(800) 395-9229
The Hussmann warranty is printed on the back
of this guide.
2
Rev.0208
R3HA with Hot Front
Hot Air Top with Hot Front Option
and Dry Rear Storage
Scale = 1/2"
Optional
8" shelf
Optional 12x20 pans
Dry
Rear
Storage
8
1
/
8
"
20 5/8" Griddle
Glow-Ray
T-5
Light
11 1/2"
Heater
T-5
Light
36
3
/
4
"
1
6
5
/
8
"
13
1
/
4
"6
1
/
4
"
6
"
50 3/4"
16
1
/
2
"
26
1
/
2
"
53"
1
12x20 Drop-In Well
3
2
3
/
4
"
G
Cut & Plan Views
1
1
/
4
"
14
5
/
8
"
r
id
d
le
18"
"
0
1
5
2
0
/
8
"
8
/
3
"
8
9
/
3
1
2
"
1
6
Service Hot / Self Service Case
"
5
0
R3H
Scale=1/2"
1
1
3
/
2
"
3
/
8
"
"
3
5
"
8
/
3
6
3
11 1/8"
1
5
1
26
/8"
Water Reservoir
Pan
5
/
8
"
26
1
/4"
8
3
/4"
33 1/8"
Circulated Hot Air Merchandiser
R3HA
8"
8"
DRAIN &
ELEC.
STUB UP
18" X 18"
CASE FRONT
8-2"
(Variable Lengths)
R3
Plan View = 1/4”
REF.
STUB UP
18" X 18"
48"
Electrical Plug
115VAC
3
"
4
/
1
32
Cutout
9
"
"
4
/
1
4
Elec
Elec Box
Water
"
4
/
1
34
Flange
"
2
/
1
10
Variable Cutout (4’,6’,8’)
1
"
1
"
R3TO
Plan view
Installation
IGFP-R3H, R3HTO, R3HA, R3Combo-0208
LOCATION
The refrigerated merchandisers have been designed for
use only in air conditioned stores where temperature and
humidity are maintained at or below 75°F and 55% relative humidity. DO NOT allow air conditioning, electric
fans, open doors or windows (etc.) to create air currents
around the merchandiser, as this will impair its correct
operation.
Product temperature should always be maintained at a
constant and proper temperature. This means that from
the time the product is received, through storage, preparation and display, the temperature of the product must
be controlled to maximize life of the product.
UN-CRATING THE STAND
Place the fixture as close to its permanent position as
possible. Remove the top of the crate. Detach the walls
from each other and remove from the skid. Unbolt the
case from the skid. The fixture can now be lifted off the
crate skid. Lift only at base of stand!
EXTERIOR LOADING
These models have not been structurally designed to sup-
port excessive external loading. Do not walk on theirtops; This could cause serious personal injury and damage to the fixture.
GLASS BREAKAGE
MAY OCCUR!
Retighten glass along clamshell
after leveling and first time case
is brought to full operating
temperature!
GLASS ADJUSTMENT
During shipment, the lubricant inside the cylinders may
have settled. This settling may cause excessive or uneven
tension on the glass - to the point of breakage. To avoid
any damage, please follow these three easy steps:
1. Slowly raise and lower each glass section 6 times to
a height of 6 inches.
2. Increase the height to 12 inches, and raise and lower
the glass 6 more times.
3. Finally raise the glass to its full extension, and lower.
These steps should release any settled lubricant within
the cylinders and prevent any stress on the front glass.
SETTING AND JOINING
The sectional construction of these models enable them
to be joined in line to give the effect of one continuous
display. A joint trim kit is supplied with each joint.
LEVELING
IMPORTANT! It is imperative that cases be
leveled from front to back and side to side prior
to joining. A level case is necessary to insure
proper operation, water drainage, and
plexiglass alignment.
NOTE: A. To avoid removing concrete flooring, begin lineup
leveling from the highest point of the store floor.
B. When wedges are involved in a lineup, set them first.
JOINING R3H, R3HA, R3 Combo's
All cases were leveled and joined prior to shipment to
insure the closest possible fit when cases are joined in the
field. When joining, use a carpenters level and shim legs
accordingly. Case must be raised correctly, under legs
where support is best, to prevent damage to case.
1. Check level of floor where cases are to be set.
Determine the highest point of the floor; cases will
be set off this point.
2. Set first case, and adjust legs over the highest part of
the floor so that case is level. Prevent damage – case
must be raised under leg or by use of 2x6 or 2x4 leg
brace. Remove side and back leg braces after case is
set.
3. Set second case as close as possible to the first case,
and level case to the first using the instructions in
step one.
4. Apply masking tape 1/8" in from end of case on
inside and outside rear mullion on both cases to be
joined.
5. Apply liberal bead of case joint sealant (butyl) to
dotted area shown in (Fig.2, #1) of first case. Apply
heavy amount to cover entire shaded area.
DO NOT USE PERMAGUM!
It is the contractor's
responsibility to install
case(s) according to local
construction and health
codes.
6. Slide second case up to first case snugly. Then level
second case to the first case so glass front, bumper
and top are flush.
7. To compress silicone at joint, use two Jurgenson
wood clamps. Make sure case is level from front to
4
Rev.0208
back and side to side on inside bulkheads at joint.
8. Attach sections together via a 2 bolts located in the
base of the case. Secure the overhead structure by
bolting the bracket, located inside behind lights.
9. Apply bead of silicone to top of bulkheads and slip
on stainless steel bulkhead cap. Also apply silicone
to seam between overhead light tubes.
10.Use finger to smooth silicone as thin as possible at
masking tape on inside and outside of rear mullion
(apply additional silicone if necessary). Remove tape
applied on line #3.
CORNER WEDGES
Corner wedges are attached via front and rear
camlocks. Use a 7mm allen wrench to turn the locks.
Do not overtighten! Join the top by using a joint
bracket (included in joint kit) with 3/8" bolts.
JOINT TRIM
After cases have been leveled and joined, and refrigeration, electrical, and wasted piping work completed, install
the splashguards. Fasten along the top edge, or center, with
#10 X 3/8" sheet metal screws.
DO NOT SEAL JOINT T RIM T O FLOOR!
Installing R3HTO, R3HATO
All cases were tested at a level state before shipping. When
joining, use a carpenters level and shim enclosing or supporting cabinet accordingly.
1. Make sure the cabinet you are installing the
R3HATO on is level.
2. Wire unit according to local codes.
1. Never use pipe for condensate drains smaller than
the nominal diameter of the pipe or P-trap supplied
with the case.
2. When connecting condensate drains, the P-trap
must be used as part of the condensate drain to
prevent air leakage or insect entrance. Store plumbing system floor drains should be at least 14" off the
center of the case to allow use of the P-trap pipe
section. Never use two water seals in series in any
one line. Double P-traps in series will cause a lock
and prevent draining.
3. Always provide as much down hill slope (“fall”) as
possible; 1/8" per foot is the preferred minimum.
PVC pipe, when used, must be supported to maintain the 1/8" pitch and to prevent warping.
4. Avoid long runs of condensate drains. Long runs
make it impossible to provide the “fall” necessary for
good drainage.
5. Provide a suitable air break between the flood rim of
the floor drain and outlet of condensate drain. 1" is
ideal.
6. Prevent condensate drains from freezing:
a. Do not install condensate drains in contact with
non-insulated suction lines. Suction lines should be
insulated with a nonabsorbent insulation material
such as Armstrong’s Armaflex.
b. Where condensate drains are located in dead air
spaces (between refrigerators or between a
refrigerator and a wall), provide means to prevent
freezing. The water seal should be insulated to
prevent condensation.
Plumbing
WASTE OUTLET AND P-TRAP
The waste outlet is located off the center of the case on
one side allowing drip piping to be run lengthwise under
the fixture. There are 3 drains in each fixture that can be
easily located.
1-1/2",1", & 3/4" P-traps and threaded adapters are supplied with each fixture. The 3 P-traps must be installed to
prevent air leakage and insect entrance into the fixture.
NOTE: PVC-DWV solvent cement is recommended.
Follow the manufacturer’s instructions.
INSTALLING CONDENSATE DRAIN
Poorly or improperly installed condensate drains can seriously interfere with the operation of this refrigerator,
and result in costly maintenance and product losses. Please
follow the recommendations listed below when installing
condensate drains to insure a proper installation:
WATER SUPPLY
Tap water contains more minerals and will contribute to
the mineral residue and buildup which may impair the case's
performance and create undesireable cleaning issues. It is
recommended that a 5 micro particle filter be used to
filter the incoming water supply. Be sure to flush the water line before hooking it up to the filter to prevent blocking the filter.
Refrigeration -R3H, R3HA with refrigerated front
REFRIGERANT TYPE
The standard refrigerant will be R-22 unless otherwise
specified on the customer order. Check the serial plate
on the case for information.
PIPING
The refrigerant line outlets are located under the case.
Locate first the electrical box, the outlets are then on the
same side of the case but at the opposite end. Insulate
5
IGFP-R3H, R3HTO, R3HA, R3Combo-0208
T-Stat &
Ballast
(Located in the
same place for
hot and cold)
Rear Storage
T-Stat and
Solenoid inside
Storage Area
Front Coils
controlled by
EPR Valve
under Deck Pan
(Right side)
suction lines to prevent condensation drippage.
REFRIGERATION LINES
LIQUIDSUCTION
3/8" O.D. 5/8" O.D.
NOTE: The standard coil is piped at 5/8" (suction); however,
the store tie-in may vary depending on the number of
coils and the draw the case has. Depending on the case
setup, the connecting point in the store may be
5
/8", 7/8", or 11/8". Refer to the particular case you are
hooking up.
Refrigerant lines should be sized as shown on the refrigeration legend furnished by the store.
Install P-traps (oil traps) at the base of all suction line vertical risers.
Pressure drop can rob the system of capacity. To keep the
pressure drop to a minimum, keep refrigerant line run as
short as possible, using the minimum number of elbows.
Where elbows are required, use long radius elbows only.
CONTROL SETTINGS
See the “Case Specs” section of this guidebook for the
appropriate settings for your merchandiser. Maintain these
parameters to achieve near constant product temperatures. Product temperature should be measured first thing
in the morning, after having been refrigerated overnight.
Defrost times should be as follows: OFF CYCLE - Consult the Case Specification Section of this guide for defrost settings. The number of defrosts per day and the
duration of the defrost cycle may be adjusted to meet
conditions present at your location.
ACCESS TO TX VALVES & DRAIN LINES
MECHANICAL - Remove product from end of case. Remove
product racks. Remove refrigeration and drain access panels
(labeled). TX valve (mechanical only) and drain are located
under each access panel at end of the case.
ELECTRONIC - The Electronic Expansion valve master and
slave cylinder(s) are located within the electrical access
panel(s).
ELECTRONIC EXPANSION VALVE (OPTIONAL)
A wide variety of electronic expansion valves and case
controllers can be utilized. Please refer to EEV and controller manufacturers information sheet. Sensors for electronic expansion valves will be installed on the coil inlet,
coil outlet, and in the discharge air. (Some supermarkets
require a 4th sensor in the return air). Case controllers
will be located in the electrical raceway or under the case.
The front Self Service Evaporator has an E.P.R. valve installed to maintain a constant discharge temperature. It is
located in the front at the right side of the case under the
fan plenum near the TX valve.
THERMOSTATIC EXPANSION VALVE LOCATION
This device is located on the same side as the refrigeration stub. A Sporlan balanced port expansion valve model
is furnished as standard equipment, unless otherwise specified by customer.
EXPANSION VALVE ADJUSTMENT
Expansion valves must be adjusted to fully feed the evaporator. Before attempting any adjustments, make sure the
evaporator is either clear or very lightly covered with frost,
and that the fixture is within 10°F of its expected operating temperature.
MEASURING THE OPERATING SUPERHEAT
1. Determine the suction pressure with an accurate
pressure gauge at the evaporator outlet.
2. From a refrigerant pressure temperature chart,
determine the saturation temperature at the
observed suction pressure.
3. Measure the temperature of the suction gas at the
thermostatic remote bulb location.
4. Subtract the saturation temperature obtained in step
No. 2 from the temperature measured in step No. 3.
3. The difference is superheat.
5. Set the superheat for 5°F - 7°F.
Evaporator Pressure Regulator
An Evaporator Pressure Regulator is installed in the front
of the self service section to maintain a constant discharge
temperature. It is located at the front right side of the
case, under the fan plenum near the TX Valve.
Service Case Temperature Control
Temperature control in the upper section of the R3 with
the Service Option is done by means of a thermostat and
suction solenoid valve. This controls both temperature and
humidity,
T-STAT LOCATION
T-Stats are located within the electrical raceway. Refer to
diagram below.
R3H
6
Rev.0208
Electrical
WIRING COLOR CODE
REFRIGERATED
GREENGROUND
PURPLEANTI-SWEAT
ORANGELIGHTS
YELLOWRECEPTACLE
RED / BLACK T-STAT /SOLENOID230V
BLACK / WHITET-STAT / SOLENOID 115V
BROWNFAN MOTORS
HOT
L1BLACK
L2ORANGE
L3BLUE
NEUTRALWHITE
NOTE: High Leg Connection
Orange Only
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the actual
configuration as checked in the “TYPE INSTALLED” boxes.
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting for all refrigerated models will be full
length fluorescent lamps located within the case at the
top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
The receptacle that is provided on the exterior back of
these models is intended for computerized scales with a
five amp maximum load, not for large motors or other
high wattage appliances. It should be wired to a dedicated
circuit.
ELECTRICAL SERVICE RECEPTACLES
(When Applicable)
The receptacles located on the exterior of the merchandiser are intended for scales and lighted displays. They
are not intended nor suitable for large motors or other
external appliances.
BEFORE
SERVICING
Always Disconnect Electrical
Power at the Main Disconnect
when servicing or replacing
any electrical component.
This includes (but not limited to) Fans,
Heaters, Thermostats, and Lights.
FIELD WIRING & SERIAL PLATE AMPERAGE
Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Field wiring from the refrigeration
control panel to the merchandisers is required for refrigeration thermostats. Most component amperes are listed
in the “Case Specs” section, but always check the serial
plate.
Ballasts are located within the access panel that runs the
length of the rear of the case. Refer to diagram below.
Windex
®
or Glass Plus® are the only solutions recommended to be used to clean the non-glare glass. The damage to the glass from improper, caustic solutions is irreparable.
In addition to cleaning the glass with the recommended
product, there are precautions that should be taken when
working and cleaning the inside of the case.
• When cleaning the inside of the cases, we recommend that the glass be fully opened and covered to
prevent solutions from splashing onto the glass and
ruining the coating on the inside.
PLEXIGLASS & ACRYLIC CARE
Improper cleaning not only accelerates the cleaning cycle
but also degrades the quality of this surface. Normal daily
buffing motions can generated static cling attracting dust
to the surface. Incorrect cleaning agents or cleaning cloths
can cause micro scratching of the surface, causing the plastic
to haze over time.
CLEANING
Hussmann recommends using a clean damp chamois, or a
paper towel marked as dust and abrasive free with 210Plastic Cleaner and Polish available by calling Sumner
Labs at 1-800-542-8656. Hard, rough cloths or paper towels will scratch the acrylic and should not be used.
ANTISTATIC COATINGS
The 210® has proven to be very effective in not only cleaning and polishing the Plexiglass surface, but also providing
antistatic and anti-fog capabilities. This product also seals
pores and provides a protective coating.
CLEANING
PRECAUTIONS
WHEN CLEANING:
Never Use a Cleaning or Sanitizing
Solution that has an OIL BASE
(these will dissolve the butyl
sealants) or AMMONIA BASE (this
will corrode the copper components
of the case)
TO PRESERVE THE ATTRACTIVE FINISH:
Do Use Water and a Mild Detergent for
the Exterior Only!
Do Not Use Abrasives or Steel Wool
Scouring Pads (these will mar the finish)
®
7
IGFP-R3H, R3HTO, R3HA, R3Combo-0208
CLEANING GLASS & MIRRORS
Only use a soft cloth and mild glass cleaner for cleaning
any glass or mirrored components. Be sure to rinse and/
or dry completely.
Never use hot water on cold glass surfaces! It
may shatter and cause serious injury! Allow glass
surfaces to warm
REPLACING FLUORESCENT LAMPS
Fluorescent lamps are furnished with a shatterproof protective coating. The same type of lamp with protective
coating must be used if replaced.
ENCAPSULITE
SHATTERPROOF COATING - SA 10645
R
Complies with FDA USDA
R
U
& OSHA Regulations
for replacement call:
1-800-395-9229
Turn switch off then on after replacing bulb
EVAPORATOR FANS
NSF
The evaporator fans are located at the center front of
these merchandisers directly beneath the display pans.
Should fans or blades need servicing, always replace fan blades
with the raised embossed side of the blade TOWARD THE
MOTOR.
COPPER COILS
The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.
TIPS & TROUBLESHOOTING
Before calling for service, check the following:
1. Check electrical power supply to the equipment for
connection.
2. Check fixture loading. Overstocking case will affect
its proper operation.
3. If frost is collecting on fixture and/or product, check
that no outside doors or windows are open—
allowing moisture to enter store. These merchandisers were designed for use in stores were temperature & humidity does not exceed 75° F and 55% H.
User Information
Stocking Refrigerated Sections
Improper temperature and lighting will cause serious product loss. Discoloration, dehydration and spoilage can be
controlled with proper use of the equipment and handling
of product. Product temperature should always be maintained at a constant and proper temperature. This means
that from the time the product is received, through storage, preparation and display, the temperature of the product must be controlled to maximize life of the product.
Hussmann cases were not designed to “heat up” or “cool
down” product—but rather to maintain an item’s proper
temperature for maximum shelf life. To achieve the protection required always:
1. Minimize processing time to avoid damaging temperature rise to the product. Product should be at
proper temperature.
2. Keep the air in and around the case area free of
foreign gasses and fumes or food will rapidly deteriorate.
3. Maintain the display merchandisers temperature
controls as outlined in the refrigerator section of
this manual.
4. Do not place any product into these refrigerators
until all controls have been adjusted and they are
operating at the proper temperature. Allow merchandiser to operate a minimum of 6 hours before
stocking with any product.
5. When stocking, never allow the product to extend
beyond the recommended load limit. Air dis-
charge and return air flue must be unobstructed at all times to provide proper refrigeration.
6. Keep the service doors closed (when applicable).
Refrigeration performance will be seriously affected
if left open for a prolonged period of time.
7. Avoid the use of supplemental flood or spot lighting.
Display light intensity has been designed for maximum visibility and product life at the factory. The use
of higher output fluorescent lamps (H.O.andV.H.O.),
will shorten the shelf life of the product.
FOOD HANDLING and HOT FOOD EQUIPMENT
These hot tables are for short-term holding and display of
precooked hot foods. They are not intended to cool or
reheat food. The temperature of the food should be approximately 160°F when first put into the hot table.
These hot tables are best suited when used in a cafeteria
type application where the food is held and served rapidly,
8
Rev.0208
within a few hours. Any attempt to use the hot table to
display large amounts of food for long periods of time will
result in dehydrated, overcooked and unsafe food. The quality of food will progressively worsen as the length of time
increases.
The deterioration of product quality is a function of time
and temperature. All products are affected even though
in a gravy or other liquid. They may appear to withstand
the temperature better than “dry” foods such as fried
chicken but this is not necessarily true. ALL foods will
continue to be affected by prolonged exposure to elevated
temperatures.
The following guidelines are provided only as a general
guide for the use of this equipment. The local health agency
for your area can provide specific temperature requirements.
Critical attention must be given to the heat controls for
these hot tables. Both the upper and lower heat controls
must be adjusted to achieve proper food temperatures.
Hot foods should be held at a minimum temperature of at
least 140°F (60°C) according to 1995 FDA Food Code.
However, increasing the temperature too high will also
cause the food to overcook, dry out, lose its flavor, texture and color. Food held for prolonged periods at high
temperatures will also lose some of their nutritional value.
Different foods will require different control settings. The
type of food, the quantities of food and length of time that
it is to remain in the hot table must be considered when
establishing control settings. Therefore, it must be the user’s
responsibility to establish the correct control settings to
maintain the food at the safest, tastiest and most saleable
condition.
Food temperatures can be accurately determined only through the use of food thermometers!
IMPORTANT OPERATION TIPS:
* Preheat case 30 minutes before loading product
using higher settings.
* Never place food directly into warmer. Always use
an inset and pan.
* Never pour water into a dry preheated warmer. This
may damage the unit. Always pour water into
warmer BEFORE preheating. Always use water in
case wells, as it provides even heat and humidity.
* Too much water or too much heat will cause
excessive condensation on the front glass, decreasing visibility.
* Make sure all pans are in the well units no matter the
configuration.
Using thermometer, check product before
*
loading in case (150°-160°).
* Always use warmer in wet operation when warming
thick food items.
* Stir thick foods such as chili, fudge and chowders
often to keep foods uniformly heated and prevent
scorching.
* At start, set wells to "7". After loading, recheck
temperature every 1/2 hour to see that unit is
operating properly. Adjust the thermostat (a higher
number for hotter and a lower number for cooler)
+
to maintain product temperature of 140°F
(60°C.)
minimum. The setting will depend on the type of
product being displayed and how much there is in
the well. Be sure to test product temperature with a
thermometer frequently for good product maintenance.
* Food must always be placed into a display pan over
the well, never directly into the well.
* Food should not be stacked above the top of the
pan. Food above the top of the pan will dry out
rapidly.
* Food juice or gravy should be stirred frequently and
any meats should be basted with the gravy. Stir and
rotate foods as needed. Wipe up spills immediately for eye appeal now, and easier cleaning later.
* Food should be rotated periodically from the
bottom to top.
* If practical, the food should be covered during slack
sale periods to reduce dehydration.
* At end of the day, remove product and let case cool.
Then clean with soap and water (use oven cleaner
on the difficult spots). Polish and clean glass with a
good glass cleaner.
CONTROLS
The controls are located at the rear of the case.
Ballast
R3HATO
Ballast Locations
9
R3H, R3HTO Section Startup
OPERATING INSTRUCTIONS
G
r
IGFP-R3H, R3HTO, R3HA, R3Combo-0208
id
d
le
Storage
Griddle
OVERHEAD LIGHTS ON / OFF
TURN
SWITCHES
ON
Check to make sure all lights
come on at start-up.
If they do not contact your
Service Department
POWER
ON / OFF
Control Panel on Rear of Case
Number of controls may vary.
LIGHTS
ON / OFF
Control Panel
Locaton
START-UP
GRIDDLE
INITIAL
SETTING
5
4
3
2
1
430-01-0365 9810
Parts of the case exterior, shelves and
light bulbs become extremely hot when
in use.
USE EXTREME CAUTION!
OVERHEAD HEAT
INITIAL
SETTING
"7"
6
S
t
a
r
t
u
7
p
8
9
10
"5"
OFF
LOHI
2
3
4
6
5
Allow case preheat for 45 minutes prior to loading
NOTE: This equipment is not designed to heat-up or cook food.
Food must be 150° - 160° when put in display.
1. Measure PRODUCT temperature hourly by inserting a food
thermometer into the food. Proper holding temperature is 140°.
2. To change temperature, increase or decrease Overhead Heat
by one number at a time. Adjust the griddle temperature as
necessary. Measure product temperature again in one hour.
Readjust if necessary.
1. Turn all switches and dials to "OFF" position.
2. Allow case to cool before cleaning.
ADJUST TEMPERATURE
SHUTDOWN
10
Rev.0208
R3HA, R3HATO Hot Circulation Air Startup and Operation
Main Power
Lights & Fans
Water Fill
Pump
Primer
(Optional)
Control Panel
Humidity
Control
Pilot Lights
Temperature
Control
Startup:
1. Turn the Main Power Switch ON. (This will enable all other switches in the case).
2. Turn Lights & Fans Switch ON.
3. Turn Water Fill System ON. (For 100% DRY Heat leave water system OFF).
4. Press “PUMP PRIME” for approximately 10 seconds (optional) to self-prime the humidity system. The water reservoir (pan)
INSIDE the case should ALWAYS be half full.
5. Turn Humidity Control knob to # 7, “STARTUP”, for maximum humidity conditions - over 7 may cause condensation on the glass.
This control will continually pump water into the water reservoir (pan) INSIDE the case
7. Turn Temperature Control knob to # 7, “STARTUP”, for initial temperature settings. (This will guarantee over 140°F safe FDA
temperatures).
Temperature Adjustment:
Adjust temperature up or down as required to maintain safe FDA Hot Food Temperatures. After adjustment, allow adequate time for change to
take place. Allow 30 minutes for product to respond. Although a discharge air temperature of approximately 170°F will guarantee safe food
temperatures throughout the case, use a thermometer to check food temperature periodically according to FDA guidelines.
Humidity Adjustment:
Adjust humidity up or down as desired for the appropriate food texture desired. More humidity for moist foods, less humidity or none for crispy
foods.
Be patient, humidity adjustments to higher or lower levels are not immediate, as existing moisture (or water content) within the hot environment
of the case rises or lowers at a slow pace.
11
IGFP-R3H, R3HTO, R3HA, R3Combo-0208
BTUDISCT-STATTYPE &FANDEFROST
LENGTHPER EVAP CASE DISCVELOC&EVAP & SIZE (") & &QTYAMPSSHELFRECEPLow PressureAMP-
NOTES:These merchandisers have been designed for use in
stores where temperatures and humidity are maintained at or
below 75°F and 55%RH. Stores are responsible for setting
their cases appropriately in conditions which vary from the
above. The number of defrosts and/or the duration may vary
for cases displaying products for which they were not
designed. Italicized data indicates optional equipment.