22
Specialty Products
Q- 3 Series
Technical Data Sheet
P/N Q3-SS
Rev G
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
ETL Sanitation
These merchandisers are manufactured to meet ANSI/National Sanitation
Foundation Standard #7 requirements.
ETL Listed
40427
ETL Sanitation
40427
1 of 22
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 24
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft*
Parallel 905
Conventional 1041
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs 6
OFFTIME
Temp Term °F 48
Failsafe Minutes 30
ELECTRIC or GAS Not Recommended
Merchandiser Drip Pipe (in.) 1 ½*
Merchandiser Glycol Pipe (in) 7/8*
Merchandiser Liquid Line (in.) 3/8*
Merchandiser Suction Line (in.) 5/8*
*Dependent on case length and refrigerant type.
GPM PSI
4ft 1.8 11.1
5ft 2.2 17.5
6ft 2.8 6.4
8ft 3.6 11.2
10ft 4.4 17.5
12ft 5.3 11.1
PHYSICAL DATA
GLYCOL REQUIREMENTS
(MODULAR COILS)

22
REFRIGERATION DATA Q3-SS-22.5 O
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 24
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/total*
Parallel 2635
Conventional 3100
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs 6
OFFTIME
Temp Term °F 48
Failsafe Minutes 30
ELECTRIC or GAS Not Recommended
REFRIGERATION DATA Q3-SS-45 O
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 24
Evaporator (F) 22
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/total*
Parallel 1098
Conventional 1292
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs 24
OFFTIME
Temp Term °F 48
Failsafe Minutes 90
Specialty Products
Q- 3 Series
Technical Data Sheet
P/N Q3-SS
Rev G
REFRIGERATION DATA Q3-SS-90 O
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 24
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/total*
Parallel 3166
Conventional 3725
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs 6
OFFTIME
Temp Term °F 48
Failsafe Minutes 30
ELECTRIC or GAS Not Recommended
2 of 22

22
Specialty Products
Q- 3 Series
Technical Data Sheet
P/N Q3-SS
Rev G
Q3-SS Q3-SS-S
With EBM Papst Evap Fan Motors 4' W1760006
5' W1760008
6' W1760009
8' W1760011
Q3-SS-R
5' 1H18063
6' 1H18064
8' 1H19618
10' 1H19620
12' 1H19622
Q3-SS-22.5O REM
Q3-SS-22.5I REM
Q3-SS-45O REM
Q3-SS-45I REM
Q3-SS-90O REM
1H19623
1H21338
1H19624
1H21339
1H19625
4' W1760005
4' 1H18062