12
Specialty Products
Q- 3 Series
Q3 REMOTE
Technical Data Sheet
P/N Q3-MC/FC
Rev C
ETL Sanitation
These merchandisers are manufactured to meet ANSI/National Sanitation
Foundation Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 27
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft* Meat Fish
Parallel 360 314
Conventional 414 361
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs 12
OFFTIME
Temp Term °F 45
Failsafe Minutes 50
ELECTRIC or GAS Not Recommended
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.) 3/8*
Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
GPM PSI
n/a n/a
PHYSICAL DATA
4ft 1.2
5ft 1.5
6ft 1.8
GLYCOL REQUIREMENTS
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
ETL Listed
40427
ETL Sanitation
40427
1 of 12

12
Specialty Products
Q- 3 Series
Q3 REMOTE
Technical Data Sheet
P/N Q3-MC/FC
Rev C
Q3-MC-R
Q3-MC-45°O REM
Q3-MC-4R 4' W1760002-02
Q3-MC/FC-4R with Water Flush 4' 1H24194
Q3-MC-6R 6' W1760002-04
Q3-MC-8R 8' W1760002-06
Q3-MC/FC-8R With L.E.D. Lights 8' 1H23782
Q3-MC-12R 12' W1760002-10
Q3-MC/FC-12R With L.E.D. Lights 12' 1H23784
W1760004