5
Specialty Products
Q1 SS WEDGE
Q1 SS WEDGE
Technical Data Sheet
Rev A
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 28
Evaporator (F) 20
ote: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
tu/hr/Total*
Parallel 2400
Conventional 2760
tu/hr/Total*
Parallel 1800
Conventional 2070
22.5° IS
tu/hr/Total*
Parallel 2400
Conventional 2760
22.5° OS
ETL Sanitation
These merchandisers are manufactured to meet ANSI/National Sanitation
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
roduct design in connection with any feature of our
roducts. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
40427
ETL Listed
ETL Sanitation
40427
Merchandiser Drip Pipe (in.) 1 ½*
Merchandiser Liquid Line (in.) 3/8*
Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types.
Actual refrigerant charge may vary by approximately
half a pound.
GPM PSI
NA NA
NA NA
NA NA
PHYSICAL DATA
4ft 1.2
5ft 1.5
6ft 1.8
GLYCOL REQUIREMENTS
1 of 5
tu/hr/Total*
Parallel 1800
Conventional 2070
90° OS
tu/hr/Total*
Parallel 3600
Conventional 4140
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
Frequency Hrs 6
OFFTIME
Temp Term °F 54
Failsafe Minutes 30
ELECTRIC or GAS Not Recommended
45° IS
45° OS
DEFROST DATA