8
Specialty Products
Q1 DC Wedge
Q1 DC Wedge
Technical Data Sheet
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F) 26
Evaporator (F) 20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/Total*
Parallel 1200
Conventional 1380
Btu/hr/Total*
These merchandisers are manufactu red t o meet ANSI/N ational Sanitat i on
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
40427
ETL Listed
ETL Sanitation
40427
Merchandiser Drip Pipe (in.) 1 ½*
Merchandiser Liquid Line (in.) 3/8*
Merchandiser Suction Line (in.) 5/8*
Estimated Charge (lb)***
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types.
Actual refrigerant charge may vary by approximately
half a pound.
GPM PSI
NA NA
NA NA
NA NA
PHYSICAL DATA
4ft 1.2
5ft 1.5
6ft 1.8
GLYCOL REQUIREMENTS
Parallel 1000
Conventional 1150
22.5° IS
Btu/hr/Total*
Parallel 1200
Conventional 1380
22.5° OS
Btu/hr/Total*
Parallel 1000
Conventional 1150
90° OS
Btu/hr/Total*
Parallel 2000
Conventional 2300
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
Frequency Hrs 6
OFFTIME
Temp Term °F 54
Failsafe Minutes 40
ELECTRIC or GAS Not Recommended
45° IS
45° OS
DEFROST DATA
1 of 8
Rev B
8
Q1-DC
Q1-DC-22.5° O REM
Q1-DC-22.5° I
Q1-DC-90°
Specialty Products
Q1 DC Wedge
Q1 DC Wedge
Technical Data Sheet
Rev B
Q1-DC-45 OS SINGLE DECK W1750011
Q1-DC-45 IS INSIDE WEDGE W1750027
Q1-DC-45 IS INSIDE WEDGE DRY CASE W1750028
Q1-DC W1750036
Q1-DC W1750043
Q1-DC W1750038
3 of 8