Hussmann PWW, PWW 4E, PWW 6E, PWW 8E, PWW 12E Datasheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0417990A
PWW
Data Sheet Set
P/N 0417990A
NSF
®
Certified
NOTE: Changed items have been underlined.
®
Item Part # Description Wiring Item #
FAN ASSEMBLIES, AND THERMOSTATS
(A) 0378349 Fan Motor, Evaporator (1)
0142780 Fan Blade
Embossing toward motor
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Merchandisers
A
PWW Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
2 of 4
Engineering
Plan Views
86 Inch
Wide Island
Bulk Produce
07-2003
Dimensions are shown as inches & (mm).
General 4 Ft 6 Ft 8 Ft 12 Ft
(A) Case length 48 1/4 (1226) 72 1/4 (1835) 96 3/8 (2448) 144 1/2 (3670)
Maximum outside dimension of case back to front 86 1/2 (2197) 86 1/2 (2197) 86 1/2 (2197) 86 1/2 (2197)
(includes bumper)
Front of splashguard to outside edge of base rail 5 7/8 (149) 5 7/8 (149) 5 7/8 (149) 5 7/8 (149) Back of case to outside edge of front base rail 69 1/2 (1765) 69 1/2 (1765) 69 1/2 (1765) 69 1/2 (1765) Front of case to outside ede of front base rail 17 (432) 17 (432) 17 (432) 17 (432) Width of base rail 2 1/8 (54) 2 1/8 (54) 2 1/8 (54) 2 1/8 (54) Stub up area between front base rail and splashguard 4 7/8 (124) 4 7/8 (124) 4 7/8 (124) 4 7/8 (124)
Electrical Service
(B) Righthand end of case to center of farthest knockout 47 1/4 (1202) 71 1/4 (1810) 95 3/8 (2423) 143 5/8 (3650)
Length of electrical raceway 11 7/8 (303) 34 5/8 (878) 34 5/8 (878) 34 5/8 (878)
*Note: Electrical field wiring connection point.
Waste Outlet
(C) Right end of case to center of waste outlet 24
1
/8
(613) 46
5
/8
(1184) 72
1
/4
(1835) 72
1
/4
(1835)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Center of waste outlet to outside edge of front base rail 3
1
/2 (89) 3 1/2 (89) 3 1/2 (89) 3 1/2 (89)
** Note: Field installed water seal outlets, tees, and connectors are shipped with case
Drip Pipe Outlet (D) Left end of case to center of drip pipe outlet 20 3/8 (517) 19 1/2 (495) 19 1/2 (495) 68 1/2 (1740) (E) Center of waste outlet to center of drip pipe outlet 3
3
/4
(95) 24
3
/4
(629) 51
7
/8
(1318) 3
3
/4
(95)
(F) Front of case to center of drip pipe outlet 24
7
/8 (632) 25 7/8 (657) 25 7/8 (657) 24 7/8 (632)
Outside diameter of drip pipe lines 1
1
/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38)
***Note: Field drip pipe connection point.
Refrigeration Outlet
(D) Right end of case to center of refrigeration outlet 9 (230) 9 (230) 9 (230) 9 (230)
Center of refrigeration outlet to outside edge of front base rail 3 1/2 (89) 3 1/2 (89) 3 1/2 (89) 3 1/2 (89)
A
B
C
Base Rail
PWW-8
69 1/2
3 1/2
(89)
(1765)
17
(432)
86 1/2
(2197)
C
L
F
D
(See Note***)
(See Note*)
E
(See Note**)
Access Area
Waste Outlet & Water Seal
Refrigeration
Outlet
G
5 7/8
(149)
Front
Loading...