P/N_0518262_A
PWR-E
Technical Data Sheet
P/N 0518262_A
NSF
®
Certified
November 2010
NOTE: Changed items have been underlined.
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
(A) 0378349 Fan Motor, Evaporator (1)
(MO.4410311)
0142780 Fan Blade
Embossing toward motor
(FB.0412780)
We reserve the right to change
or revise specifications and
product design in connection
with any feature of our
products. Such changes
do not entitle the buyer to
corresponding changes,
improvements, additions or
replacements for equipment
previously sold or shipped.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
PWR-E Technical Data Sheet2 of 5
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Front
PWR-8E
Waste Outlet
& Water Seal
H
A
Base Rail
Refrigeration Outlet
(See Note***)
Access Area
(See Note*)
5 7/8
(149)
9
(230)
3 1/2
(89)
81 1/2
(2070)
98 1/2
(2502)
C
L
B
C
G
(See Note**)
F
E
D
Engineering
Plan Views
98 Inch
Wide Island
Bulk Produce
11-2010
Dimensions are shown as inches & (mm).
General 8 Ft 12 Ft
(A) Case length 96 3/8
(2448) 144
1
/2
(3670)
Each End and Partition adds 1 1/2 in. (38 mm) to the length of the lineup.
Maximum outside dimension of case back to front (includes bumper) 98 1/2 (2502) 98 1/2 (2502)
Front of splashguard to outside edge of base rail 5 7/8 (149) 5 7/8 (149)
Back of case to outside edge of front base rail 81 1/2 (2070) 81 1/2 (2070)
Front of case to outside ede of front base rail 17 (432) 17 (432)
Width of base rail 2 1/8 (54) 2 1/8 (54)
Stub up area between front base rail and splashguard 4 7/8 (124) 4 7/8 (124)
Electrical Service
(B) Righthand end of case to center of farthest knockout 95 3/8
(2423) 143
1
/2
(3645)
Length of electrical raceway 34
5
/
8 (878) 34
5
/
8 (878)
*Note: Electrical field wiring connection point.
Waste Outlet
(C) Righthand end of case to center of waste outlet 72 1/4 (1835) 72 1/4 (1835)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102)
Center of waste outlet to outside edge of front base rail 3 1/
2 (89) 3
1
/
2 (89)
** Note: Field installed water seal outlets, tees, and connectors are shipped with case
Drip Pipe Outlet
(D) Left end of case to center of drip pipe outlet 19
1
/2 (495) 68 1/2 (1740)
(E) Center of waste outlet to center of drip pipe outlet 51 7/8 (1318) 3 3/4 (95)
(F) Front of case to center of drip pipe outlet 25 7/8 (657) 24 7/8 (632)
Outside diameter of drip pipe lines 1
1
/2 (38) 1 1/2 (38)
***Note: Field drip pipe connection point.
Refrigeration Outlet
(G) Righthand end of case to center of refrigeration outlet 9 (230) 9 (230)
Center of refrigeration outlet to outside edge
of front base rail 3
1
/
2 (89) 3
1
/
2 (89)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8