Hussmann PWR-E Specifications

Page 1
P/N_0518262_A
PWR-E
Technical Data Sheet
P/N 0518262_A
NSF
®
Certified
November 2010
A
Item Part # Description Wiring Item #
F
AN ASSEMBLIES, AND THERMOSTATS
(A) 0378349 Fan Motor, Evaporator (1)
(MO.4410311)
0142780 Fan Blade
Embossing toward motor (FB.0412780)
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Page 2
PWR-E Technical Data Sheet2 of 5
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Front
PWR-8E
Waste Outlet & Water Seal
H
A
Base Rail
Refrigeration Outlet
(See Note***)
Access Area
(See Note*)
5 7/8
(149)
9
(230)
3 1/2
(89)
81 1/2
(2070)
98 1/2
(2502)
C
L
B
C
G
(See Note**)
F
E
D
Engineering
Plan Views
98 Inch
Wide Island
Bulk Produce
11-2010
Dimensions are shown as inches & (mm).
General 8 Ft 12 Ft
(A) Case length 96 3/8
(2448) 144
1
/2
(3670)
Each End and Partition adds 1 1/2 in. (38 mm) to the length of the lineup.
Maximum outside dimension of case back to front (includes bumper) 98 1/2 (2502) 98 1/2 (2502) Front of splashguard to outside edge of base rail 5 7/8 (149) 5 7/8 (149) Back of case to outside edge of front base rail 81 1/2 (2070) 81 1/2 (2070) Front of case to outside ede of front base rail 17 (432) 17 (432) Width of base rail 2 1/8 (54) 2 1/8 (54) Stub up area between front base rail and splashguard 4 7/8 (124) 4 7/8 (124)
Electrical Service
(B) Righthand end of case to center of farthest knockout 95 3/8
(2423) 143
1
/2
(3645)
Length of electrical raceway 34
5
/
8 (878) 34
5
/
8 (878)
*Note: Electrical field wiring connection point.
Waste Outlet
(C) Righthand end of case to center of waste outlet 72 1/4 (1835) 72 1/4 (1835)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Center of waste outlet to outside edge of front base rail 3 1/
2 (89) 3
1
/
2 (89)
** Note: Field installed water seal outlets, tees, and connectors are shipped with case
Drip Pipe Outlet (D) Left end of case to center of drip pipe outlet 19
1
/2 (495) 68 1/2 (1740)
(E) Center of waste outlet to center of drip pipe outlet 51 7/8 (1318) 3 3/4 (95) (F) Front of case to center of drip pipe outlet 25 7/8 (657) 24 7/8 (632)
Outside diameter of drip pipe lines 1
1
/2 (38) 1 1/2 (38)
***Note: Field drip pipe connection point.
Refrigeration Outlet
(G) Righthand end of case to center of refrigeration outlet 9 (230) 9 (230)
Center of refrigeration outlet to outside edge of front base rail 3
1
/
2 (89) 3
1
/
2 (89)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Page 3
P/N 0518262_A 3 of 5
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Excel PWR-E
Produce
Wide Island, 1 Display Level
REFRIGERATION DATA
Note: This data is based on store
temperature and humidity that does not exceed 75°F and 55% R.H.
PWR-
8, 12E
Discharge Air (°F) 34
Evaporator(°F) 24
Unit Sizing (°F) 22
Btu/hr/ft PWR-
8, 12E
Parallel 1255
Conventional 1385
DEFROST DATA
PWR-
8, 12E
Frequency (hr) 6
Defrost Water (lb/ft/day) 8
(± 15% based on case configuration and
product loading).
O
FFTIME
PWR-
8, 12E
Temp Term (°F) N/A
Failsafe (minutes) 45
Standard Defrost Thermostat NA
CONVENTIONAL CONTROLS
Low Pressure Backup Control
PWR-
8, 12E
CI/CO* 17°/ 7° F
Indoor Unit Only, Pressure Defrost
Termination** 48° F
*Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Estimated Charge (lb)** PWR-
8, 12E
8 ft 2.8 lb 45 oz 1.3 kg
12 ft 4.3 lb 69 oz 2.0 kg
***This is an average for all
refrigerant types. Actual refrigerant charge may vary by approximately
0.5 lb (8 oz / 0.2 kg).
L
C
Front
of
Case
COIL
Optional
Rack
Positions
PWR-E
Electrical
44
(1118)
30
3
/8
(772)
39
7
/8
(1013)
6 (152)
15
1
/2
(394)
39
7
/8
(1013)
12
3
/8
(314)
5
1
/2 (114)
FAN
COIL
81
1
/2 (2070)
98
1
/2 (2502)
17
(432)
5
7
/8
(149)
9
(229)
3
1
/2 (89)
25
1
/2
(648)
17
3
/8
(441)
Dimensions are shown as inches & (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
PWR-E Technical Data Sheet4 of 5
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Excel PWR-E
Produce
Electrical Data
Number of Fans 8 ft 12 ft Refrigeration — 9W 2 3 Refrigeration — 9W (Export) 2 3
Amperes Watts Merchandiser 8 ft 12 ft 8 ft 12 ft Fans (Refrigeration)
Standard (120V 60Hz) 1.54 2.31 124 186 Energy Efficient (120V 60Hz) 0.76 1.14 50 75 Export (230V 50 Hz) 0.94 1.41 140 210
Min. Circuit Ampacity
With Standard Fans (120V 60Hz) 1.74 2.51 With Energy Efficient Fans (120V 60Hz) 0.96 1.34 With Export Fans (230V 50 Hz) 1.14 1.61
Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15
Standard Lighting
None
Optional Lighting
None
Optional Shelf Lighting
None
Page 5
5 of 5P/N 0518262_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Fan Wiring Offtime Defrost
= 120V POWER
= 120V NEUTRAL
1, 2 & 3 Fans
120V NEUTRAL
BROWN BAND
120V POWER
Fans
1
B
ROWN BAND
8 ft
12 ft
WARNING
All components must have a mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Excel PWR-E
Produce
ESTIMATED SHIPPING WEIGHT
4
Case Flat End
8 ft 12 ft (each)
lb (kg) 1000 (454) 1200 (544) 80 (36)
4
Actual weights will vary according to optional kits included.
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 8.33 ft3 /ft (0.77 m3 /m)
ARI Total Display Area
2
(Sq Ft/Ft) 6.67 ft2/ft (2.03 m2 /m)
Shelf Area 3(Sq Ft/Ft) 7.17 ft2/ft (2.19 m2 /m)
1
ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using ARI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann
Product Reference Guide. The standard shelf complement for this model is NONE.
Loading...