REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
PW PW
6,8,12 4,6,8,12E
Discharge Air (°F) 34 34
Evaporator(°F) 21 24
Unit Sizing (°F) 19 22
Btu/hr/ft* PW PW
6,8,12 4,6,8,12E
Parallel 1230 1090
Conventional 1355 1205
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
PW PW
6,8,12 4,6,8,12E
Frequency (hr) 6 6
Defrost Water (lb/ft/day) 8 8
(± 15% based on case configuration and
product loading).
OFFTIME PW PW
6,8,12 4,6,8,12E
Temp Term (°F) N/A N/A
Failsafe (min) 45 45
CONVENTIONAL CONTROLS
Low Pressure Backup Control
PW PW
6,8,12 4,6,8,12E
CI/CO** 14°/4° F 17°/ 7° F
Indoor Unit Only, Pressure Defrost
Termination** 48° F 48° F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 11/2
Liquid Line (in.)
3
/8
Suction Line (in.)
7
/8
Estimated Charge (lb)*** PW PW
6,8,12 4,6,8,12E
4 ft 1.9 2.3
6 ft 1.9 2.3
8 ft 2.4 2.8
12 ft 3.7 4.3
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by
Each End/Partition (in.) 1 1/2
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0384135B
Impact PW
Produce
Wide Island, 1 Display Level
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF®) Standard #7 requirements.
5 in. optional kit
for additional height