Hussmann P4NE Datasheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0415128A
Note: Changed items have been underlined
.
Merchandisers
®
E
E
E
P4NE
Data Sheet Set
P/N 0415128A
NSF
®
Certified
August 2004
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0141070 Fan Blade
embossing toward motor
B. 0411744 Standard Non-adjustable (2)
Defrost Thermostat
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
D. 0428648 Ballast, Electronic
2 lamps (4)
D. 0428649 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P4NE Data Sheet
Front Base Rail
A
72
1
/4 (1835)
4 3/8 (111)
Refrigeration
Outlet
Waste Outlet
Water Seal
9
(230)
Electrical
31
(787)
Access Area
40 5/8
(1030)
27
(686)
Front
27
1
/2
(699)
(see note*)
29 1/2
(749)
33 1/2
(851)
3 (076)
4 (102)
B
C
Dimensions shown as inches and (mm).
8 Ft 12 ft
General
(A) Length of Case (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
Maximum outside dimensions of case back to front (includes bumper) 40
5
/8 (1030) 40 5/8 (1030)
Back of case to front of splashguard 33 1/
2 (851) 33
1
/
2 (851)
Back of case to outside edge of front skidrail 29
1
/2 (749) 29 1/2 (749) Width of skidrail 2 1/8 (54) 2 1/8 (54) Distance between inside edges of external support and center support 40 5/
8 (1032) 40
5
/
8 (1032)
Distance between inside edges of center supports NA 44 (1118) Width of external support 4
1
/8 (105) 4 1/8 (105) Stub-up area between front skidrail and splashguard 3 (76) 3 (76) Right edge of case (excluding end) to inside edge of external support 1 3/8 (35) 1 3/8 (35)
Electrical Service
(B) Right end of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467)
Back outside of case to center of knockout 31 (787) 31 (787) Length of electrical raceway 34 1/2 (878) 34 1/2 (878)
*Note: Electrical Field Wiring Connection Point
Waste Outlet
(C) Right end of case to center of waste outlet 24 1/8 (613) 72 1/4 (1835)
Left end of case to center of waste outlet 72 1/4 (1835) 72 1/4 (1835) Back outside of case to center of waste outlet 27 (686) 27 (686)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of drip pipe 1 1/2 (38) 1 1/2 (38) **Note: Water seal outlet must clear front skid rail.
Refrigeration Outlet
Right end of case to center of refrigeration outlet 9 (230) 9 (230) Back outside of case to center of refrigeration outlet 27 1/2 (699) 27 1/2 (699)
Engineering
Plan View
P4NE
All Produce
09-2003
Loading...