HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0457240A
Note: Changed items have been underlined.
P4EPLUS
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator
0380485 Fan Blade
embossing toward motor
B. 0137880 Optional Adjustable (2)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. 0428648 Ballast 2 lamps (3)
0428649 Ballast 3 lamps (3)
D. Fluorescent Lamp (4)
Replace with like fixtures
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Data Sheet Set
P/N 0457240A
®
NSF
Certified
March 2005

2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P4EPLUS Data Sheet
Electrical
Refrigeration
72 1/4 (1835)
4
1
/8 (105)
24
1
/8 (613)
5
1
/2 (140)
1
3
/8 (35)
4
1
/2 (114)
29
1
/2
(749)
35
1
/8
(891)
46
1
/4
(
1174)
9
(230)
30
5
/8
(778)
27
1
/2
(699)
40
5
/8
(1032)
4 (102)
Water Seal
(See Note*)
Waste Outlet
4 (102)
40
5
/8
(1032)
30
1
/2
(775)
96
3
/8 (2448)
88
3
/8 (2245)
Dimensions shown as inches and (mm).
8 Ft 12 ft
General
Length of Case (without ends or partitions) 96
3
/8 (2448) 144 1/2 (3670)
Maximum outside dimensions of case back to front (includes bumper) 46
1
/
4 (1174) 46
1
/
4 (1174)
Back of case to front of splashguard 35
1
/8 (891) 35 1/8 (891)
Back of case to outside edge of front skidrail 29
1
/2 (749) 29 1/2 (749)
Width of skidrail 4
1
/
2 (114) 4
1
/
2 (114)
Right end of case to outside edge of external support 5
1
/2 (140) 5 1/2 (140)
Distance between inside edges of external support and center support 40
5
/8 (1032) 40 5/8 (1032)
Distance between inside edges of center supports NA 44 (1118)
Width of external support 4
1
/8 (105) 4 1/8 (105)
Stub-up area between front skidrail and splashguard 4 (102) 4 (102)
Right edge of case (excluding end) to inside edge of external support 1
3
/8 (35) 1 3/8 (35)
Electrical Service
Right end of case to center of farthest knockout 88
3
/8 (2245) 136 1/2 (3467)
Back outside of case to center of knockout 30
1
/2
(775) 30
1
/2
(775)
Length of electrical raceway 34
1
/2 (778) 34 1/2 (778)
Waste Outlet
Right end of case to center of waste outlet 24
1
/8 (613) 72 1/4 (1835)
Left end of case to center of waste outlet 72
1
/4 (1835) 72 1/4 (1835)
Back outside of case to center of waste outlet 27
1
/2
(699) 27
1
/2
(699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102)
Outside diameter of drip pipe 1
1
/2 (38) 1 1/2 (38)
*Note: Water seal outlet must clear front skid rail.
Refrigeration Outlet
Right end of case to center of refrigeration outlet 9 (230) 9 (230)
Back outside of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778)
Engineering
Plan View
Produce
12-2003

P/N 0457240A
3 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
7 1/2
(152)
51
(1295)
38 1/8
(969)
3 1/8 (79)
81 1/8
(2061)
53 3/4
(1365)
30 1/8
765)
6 1/2 (165)
53 1/8
(1360)
12 5/8
(319)
4 (102)
27 1/2 (699)
4
(102)
4 1/2 (114)
29 1/2 (749)
35 1/8 (891)
46 1/4 (1174)
26 1/4
(670)
FAN
C
O
I
L
P4EPLUS
21 1/2
(545)
12 3/4
(322)
Impact P4EPLUS
All Produce
Multi-deck, 2 Display Levels
Dimensions shown as inches and (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF ®) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
MODULAR
P
RODUCE
P4EP
LUS UNLIT LIT INSERT*†
Discharge Air °F 33 31 33
Evaporator °F 30 28 30
Unit Sizing °F 28 26 28
* All display levels must use baffles.
Btu/hr/ft** U
NLIT LIT INSERT
Parallel 1275 1315 1160
Conventional 1390 1435 1265
**For all refrigeration equipment other than
Husssmann, use conventional BTU values.
DEFROST DATA
P4EPLUS
Frequency (hr) 6
Defrost Water (lb/ft/day) 9
(±15% based on case configuration and
product loading.
O
FFTIME P4EPLUS
Time (minutes) 30
E
LECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
P4EP
LUS
CI/CO*** 21/11°F
Indoor Unit Only, Pressure Defrost
Termination*** 48°F
***Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Liquid Line (in.)
3
/8
Suction Line (in.)
7
/
8
Estimated Charge (lbs)****
P4EP
LUS
8 ft 3.7
12 ft 5.1
****This is an average for all refrigerant
types actual refrigerant charge may vary by
approximately half a pound.
Length (in.) Added to Lineup
by Each End or Insulated
Partition 1
1
/
2
† This is test data for one third-party insert. Contact your Hussmann representative
for further information.

4 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P4EPLUS Data Sheet
Impact P4EPLUS
Bulk Produce
Electrical Data
8 Ft 12 Ft
Number of Fans — 6W 2 3
Amperes Watts
Merchandiser 8 Ft 12 Ft 8 Ft 12 Ft
Fans
Standard (120V 60Hz) 2.80 4.20 210 320
Energy Efficient (120V 60Hz) 1.52 2.28 100 150
Export (230V 50Hz) 1.52 2.28 228 342
Constant on Anti-sweat Heaters NA
Cycling Anti-sweat Heaters NA
Min. Circuit Ampacity
With Standard Fans (120V 60Hz) 3.00 4.40
Export (230V 50Hz) 1.72 2.48
With Energy Efficient Fans (120V 60Hz) 1.72 2.48
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Supplemental Gas Heaters NA
208V 1ΦΦElectric Defrost NA
Standard Lighting
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Rail 1.02 1.54 118 170
2 Rows Canopy 1.02 1.54 118 170
2 Rows Canopy and 1 Row Rail 1.53 2.31 177 255
Optional Shelf Lighting
1 Row of Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255

P/N 0457240A
5 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Refrigeration
Thermostat
2
To
Condensing
Unit
}
Light Blue
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
=
120V POWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring
Offtime Defrost
4 & 6 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
BROWN BAND
Connector
Connector
G
Connector
Connector
Connector
Connector
Connector
Optional Shelf Harness and Light Circuits for
One Row of Shelves
120 V
Power
B
W
G
B
BL
BL
BL
G
G
R
R
BL
BL G
W
BL
Shelf Harness
Shelf Light Circuits
BL
G
R
4
3
W
BL
R
4
BL
R
G
G
R
R
R
G
Shelf Lighting
G G
R
BL
4
BL
Connector
Connector
B

P4EPLUS Data Sheet
6 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting — 1 Row Canopy (Standard on Multi-deck)
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
Light
Switch
W
B
3
BL
Optional Lighting — 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
Light
Switch
B
W
3
W
B
3
BL
BL
BL
R
R
R
BL
44
BL
4
BL
4
R
BL
R
4
BL
R
4
R
4
R
4
R
4
Optional Lighting — 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN
BAND
B
Light
Switch
All components must have mechanical ground, and the merchandiser must be grounded.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
W
3
R
BL
BL
4
4
WARNING
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
= 120V POWER = 120V NEUTRAL
BL
R
R
4