P2X-EP
Technical Data Sheet
P/N 0463873_D
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES
8 Ft & 12 Ft
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780)
7W Energy Efficient Fan Assembly (1)
0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
LAMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676)
0480131 3 lamps (BA.4481654)
0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision F adds EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other
changes marked by bar, underline or circle.
We reserve the right to change or revise specifications
and product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
2 of 10 P2X-EP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as inches and (mm).
Produce
10-2004
NOTE: Case-to-Case Electrical Connections
are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical
Field
Connection
30 1/4
(768)
P2X
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/8
(2448) 144
1
/2
(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851)
Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768)
Distance between edges of external legs and center legs 41 1/2
(1054) 41
1
/2
(1054)
Distance between edges of center legs NA 43
7
/8 (1114)
Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612)
Length of electrical wireway 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 84
1
/4
(2140) 132
3
/8
(3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307)
Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665)
RH end of case to center of refrigeration outlet 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4
Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
P2X-EP UNLIT
LIT
Discharge Air °F 39 39
Evaporator °F 34 34
Unit Sizing °F 32 32
Btu/hr/ft
‡
— Unlit Shelves
‡‡
P2X-EP Parallel Conventional
U
NLIT 910 910
‡
Optional energy efficient motors reduce the
refrigeration load by 21 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
P2X-EP
Frequency (hr) N
ONE
Defrost Water (lb/ft/day) 6
(± 15% based on case configuration and
product loading).
O
FFTIME P2X-EP
Time (minutes) N
ONE
E
LECTRIC OR GAS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
P2X-EP
CI/CO* 27°F / 17°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge** P2X-EP
8 ft 2.7 lb 43 oz 1.2 kg
12 ft 3.9 lb 62 oz 1.8 kg
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
3 of 10P/N 0463873_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
4 3/4 (120)
31 5/8 (804)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
Refrigeration
Outlet
30 1/4
(768)
42 1/2
(1080)
34 5/8
(878)
36 1/4
(920)
FAN
C
O
I
L
P2X-EP
28 5/8
(727)
3 In. (77 mm)
Required
Air Gap
7 1/4 (183)
31
(787)
15
(381)
16 1/4
(412)
Electrical
Case to Case
Connections
74 3/8
(1890)
Impact
Excel
P2X-EP
Bulk Produce
Multi-deck, 2 Display Levels
Dimensions shown as inches and (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.