Hussmann P2 Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0378424B
Item Part # Description Wiring Item # F
AN ASSEMBLIES AND THERMOSTATS
A. 6W Fan Assembly 1
0058698 Fan Motor, Evaporator 0142780 Fan Blade
B. 0411744 Standard Non-adjustable 2
Thermostat
C. 0137880 Optional Adjustable 3
Refrigeration Thermostat
Note: Changed items have been underlined.
Merchandisers
®
D
E
B
D
C
E
A
P2
Data Sheet Set
P/N 0378424B
NSF
®
Certified
December, 2003
Item Part # Description Wiring Item # L
AMPS AND BALLASTS
D. 0428648 Ballast 2 lamps 4
D. 0428649 Ballast 3 lamps 4
E. Fluorescent Lamp 5
Replace with like fixtures
Page 2
2 of 6
P2 Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical
Refrigeration
72 1/4 (1835)
4
1
/8 (105)
24
1
/8 (613)
5
1
/2 (140)
1
3
/8 (35)
4
1
/2 (114)
29 1/2 (749)
35
1
/8
(891)
46
1
/4
(
1174)
9
(230)
30
5
/8
(778)
27
1
/2
(699)
40
5
/8
(1032)
4 (102)
Water Seal
(See Note*)
Waste Outlet
4 (102)
40
5
/8
(1032)
30
1
/2
(775)
96
3
/8 (2448)
88
3
/8 (2245)
Dimensions shown as inches and (mm).
8 Ft 12 ft
General
Length of Case (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670) Maximum outside dimensions of case back to front (includes bumper) 46 1/
4 (1174) 46
1
/
4 (1174)
Back of case to front of splashguard 35
1
/8 (891) 35 1/8 (891) Back of case to outside edge of front skidrail 29 1/2 (749) 29 1/2 (749) Width of skidrail 4 1/
2 (114) 4
1
/
2 (114)
Right end of case to outside edge of external support 5
1
/2 (140) 5 1/2 (140) Distance between inside edges of external support and center support 40 5/8 (1032) 40 5/8 (1032) Distance between inside edges of center supports NA 44 (1118) Width of external support 4 1/8 (105) 4 1/8 (105) Stub-up area between front skidrail and splashguard 4 (102) 4 (102) Right edge of case (excluding end) to inside edge of external support 1 3/8 (35) 1 3/8 (35)
Electrical Service
Right end of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467) Back outside of case to center of knockout 30 1/
2 (775) 30
1
/
2 (775)
Length of electrical raceway 34
1
/2 (876) 34 1/2 (876)
Waste Outlet
Right end of case to center of waste outlet 24 1/8 (613) 72 1/4 (1835) Left end of case to center of waste outlet 72 1/4 (1835) 72 1/4 (1835) Back outside of case to center of waste outlet 27 1/
2 (699) 27
1
/
2 (699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of drip pipe 1
1
/
2 (38) 1
1
/
2 (38)
*Note: Water seal outlet must clear front skid rail.
Refrigeration Outlet
Right end of case to center of refrigeration outlet 9 (230) 9 (230) Back outside of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778)
Engineering
Plan Views
Produce
12-2003
Page 3
3 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0378424B
C O
I
L
P2
38
1
/
8
(969)
7
1
/
2
(152)
30
1
/
2
(774)
3
1
/
8
(079)
39
1
/
2
(1002)
42
1
/
2
(1079)
74
(1878)
27 1/
2
(699)
29 1/
2
(749)
35 (891)
46
1
/
2
(1174)
30
1
/
4
(770)
25
1
/
2
(647)
17
3
/
8
(441)
REFRIGERATION DATA
Note: This data is based on store
temperature and humidity that does not exceed 75°F and 55% R.H.
P2 P2E
Discharge Air °F 37 33
Evaporator °F 21 24
Unit Sizing °F 19 22
Btu/hr/ft** P2 P2E Parallel 1015 970 Conventional 1090 1050
**For all refrigeration equipment other than Husssmann, use conventional BTU values.
DEFROST DATA
P2 P2E
Frequency (hr) 68 Defrost Water (lb/ft/day)66
(±15% based on case configuration and product loading.
OFFTIME
P2 P2E
Temp Term °F 48°F 48°F Failsafe Minutes 30 30
E
LECTRIC OR G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
P2 P2E
CI/CO** 14/4°F 17/7°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2 Liquid Line (in.)
3
/8
Suction Line (in.)
7
/8
Estimated Charge (lbs)***
P2 P2E
8 ft 1.5 2.3 12 ft 2.0 3.3
***This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound.
Length (in.) Added to Lineup by Each End or Insulated Partition 1
1
/2
Impact P2
Bulk Produce
Single Deck, 1 Display Level
Dimensions shown as inches and (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ®) Standard #7 requirements.
Page 4
4 of 6
P2 Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
P2
Bulk Produce
Electrical Data
8 ft 12 ft
Number of Fans — 6W 2 3
Amperes Watts
Merchandiser 8 ft 12 ft 8 ft 12 ft
Fans
Standard (120V 60Hz) 1.00 1.50 78 117 Export (230V 50Hz) 0.56 0.84 88 132
Energy Efficient (120V 60Hz) 0.52 0.78 36 54 Constant on Anti-sweat Heaters NA Cycling Anti-sweat Heaters NA Min. Circuit Ampacity
With Standard Fans (120V60Hz) 1.20 1.70
Export (230V 50Hz) 0.76 1.04
With Energy Efficient Fans (120V 60Hz) 0.72 0.98
Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15
Supplemental Gas Heaters NA
208V 1
ΦΦ
Electric Defrost NA
Optional Shelf Lighting 1 Row of Shelves 0.51 0.77 59
Page 5
P/N 0378424B
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
5 of 6
Defrost
Termination
Thermostat
2
To Condensing Unit
}
Dark Blue
Fan Wiring
Offtime Defrost
2 & 3 Fans
120V NEUTRAL
BROWN BAND
120V POWER
Fans
1
B
ROWN BAND
Light Blue
3
Refrigeration
Thermostat
Optional Shelf Harness and Light Circuits for One Row of Shelves
Shelf Harness
Connector
W
B
120 V
Power
Connector
G
B
W
4
BL
R
BL
BL
W
G
G
G
R
BL
Connector
Shelf Lighting
B
G
BL
R
Connector
BL G
R
Connector
G
BL
R
G
R
BL
Connector
Shelf Light Circuits
BL
Connector
G
Connector
G G
R
5
BL
R
5
Connector
BL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
R
5
Page 6
6 of 6
P2 Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting 1 Row Canopy (Standard on Multideck)
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
4
BL
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
4
W
B
4
BL
R
BL
BL
R
BL
BL
BL
R
R R
BL
R
BL
R R
R
Optional Lighting 1 Row Rail
120V NEUTRAL
120V POWER
ORANGE OR TAN BAND
B
Light
Switch
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
ORANGE OR TAN BAND
W
4
R
BL
BL
WARNING
Grayed components in 12 foot models only.
= 120V POWER = 120V NEUTRAL
BL
R
R