REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H. Schedule defrost at night while
lights are off.
P1X49MOB-B
Discharge Air °F 31
Evaporator °F 24
Unit Sizing °F 22
Btu/hr/case 594
DEFROST DATA
P1X49MOB-B
Frequency (hr) 8
Defrost Water (lb/ft/day) NA
(±15% based on case configuration and
product loading.)
O
FFTIME
P1X49MOB-B
Temp Term °F 43°F
Failsafe Minutes 35
E
LECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
P1X49MOB-B
CI/CO** 14 / 4°F
Indoor Unit Only, Pressure Defrost
Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.) 1 1/
2
Liquid Line (in.)
3
/8
Suction Line (in.)
5
/8
Estimated Charge (lbs)***
P1X49MOB-B
6 ft 3.6
8 ft 4.0
***This is an average for all refrigerant types
actual refrigerant charge may vary by approximately half a pound.
Length (in.) Added to Lineup by Each
End or Insulated Partition 1
1
/2
Impact P1X49MOB-B
Bulk Produce, Self-Contained
Single Deck, 49 Inch High Back, 1 Display Level
Mobile Self-Contained
Dimensions shown as inches and (mm).
3 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0457222