REFRIGERATION DATA
Note: This data is based on store tempera-
ture and humidity that does not exceed
75°F and 55% R.H.
P1X49
Discharge Air °F 31
Evaporator °F 24
Unit Sizing °F 22
Btu/hr/ft** P1X49
Parallel 559
Conventional 594
**For all refrigeration equipment other than
Hussmann, use conventional BTU values.
DEFROST DATA
P1X49
Frequency (hr) 8
Defrost Water(lb/ft/day) 4
(±15% based on case configuration and
product loading.)
O
FFTIME P1X49
Temp Term °F 43°F
Failsafe Minutes 35
E
LECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONALCONTROLS
Low Pressure Backup Control
P1X49
CI/CO** 14/4°F
Indoor Unit Only, Pressure Defrost
Termination** 48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/2
Liquid Line (in.)
3
/8
Suction Line (in.)
5
/8
Estimated Charge (lbs)***
P1X49
8 ft 1.5
12 ft 2.0
***This is an average for all refrigerant
types actual refrigerant charge may vary by
approximately half a pound.
Length (in.) Added to Lineup by Each
End or Insulated Partition 1
1
/2
Impact P1X49
Bulk Produce
Single Deck, 49 Inch High Back, 1 Display Level
Dimensions shown as inches and (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF ®) Standard #7 requirements.
3 of 4
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 00457221