P1NX-E
Technical Data Sheet
P/N 0480163_D
NSF
®
March 2010
Item Part # Description Wiring Item #
FAN ASSEMBLIES 4 Ft, 8 Ft 10 Ft& 12 Ft
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0464847 Fan Blade (FB.4780649)
6 Ft and 10 FtOnly
A. 4W Standard Fan Assembly (1)
0392457 Fan Motor, Evaporator
(MO.4410101)
0252116 Fan Blade (FB.4780611) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator
(MO.4410544)
0252116 Fan Blade (FB.4780611)
10 Ft uses both.
Item Part # Description Wiring Item #
THERMOSTATS
B. 0382028 Standard Non-adjustable (2)
Defrost Thermostat (CT.0382028)
C. Optional Adjustable
Refrigeration Thermostat (3)
LAMPS AND BALLASTS
None
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision D adds Btu note (page 3). Other changes marked by bar, underline or circle.
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Page 2
2 of 5 P1NX-E Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as in. and (mm).
Bulk Produce
09-2005
Wireway
26 3/4
(680)
25 1/4
(641)
37
(940)
A
41 1/2
(1054)
28 1/2
(724)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
4 3/4 (120)
21 1/4
(540)
D
C
8 (203)
12 1/8 (307)
4 1/4 (108)
41 1/2
(1054)
43 7/8
(1114)
B
Splashguard
19
(483)
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Electrical
Stub Up Area
6 x 6
(152x152)
Electrical Field Connection
26 1/2
(673)
4 3/4 (120)
4 1/2 (115)
P1NX
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
5
/8
4 ft 6 ft 8 ft 10 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/8 (1229) 72 3/8 (1838) 96 3/8 (2448) 120 3/8 (3058) 144 1/2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 37 (940) 37(940) 37 (940) 37 (940) 37 (940)
Back of case to front of splashguard 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) 28 1/2 (724)
Back of case to O/S edge of front leg 25 1/
4 (641) 25
1
/
4 (641) 25
1
/
4 (641) 25
1
/
4 (641) 25
1
/
4 (641)
Distance between edges of external legs and center legs NA 29
1
/2 (750) 41 1/2 (1054) 29 1/2 (749) 41 1/2 (1054)
Distance between edges of center legs NA NA NA 43 7/8 (1114) 43 7/8 (1114)
Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 108 1/4 (2750) 132 3/8 (3363)
Back of case to center of stub up area 19 (483) 19 (483) 19 (483) 19 (483) 19 (483)
Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42 1/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 114 1/4 (2902) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 108 1/4 (2750) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307)
Back O/S of case to center of waste outlets 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) 26 3/4 (680)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) 21 1/4 (540)
RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203) 8 (203)
Wireway
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
P1NX-E
Discharge Air (°F) 31
Evaporator (°F) 24
Unit Sizing (°F) 22
Btu/hr/ft
P1NX-E
Parallel 575
Conventional 610
Optional energy efficient motors reduce the
refrigeration load by 14 Btu/hr/ft.
DEFROST DATA
P1NX-E
Frequency (hr) 8
Defrost Water (lb/ft/day) 4
(± 15% based on case configuration and
product loading).
OFFTIME P1NX-E
Temp Term (°F) 43°F
Failsafe (minutes) 35
ELECTRIC OR GAS Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
P1NX-E
CI/CO** 17°F / 7°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** P1NX-E
4 ft 0.9 lb 14 oz 0.4 kg
6 ft 1.2 lb 19 oz 0.5 kg
8 ft 1.7 lb 27 oz 0.8 kg
10 ft 2.1 lb 34 oz 1.0 kg
12 ft 2.3 lb 37 oz 1.0 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 5
P/N 0480163_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
17 1/4
(438)
43 1/8
(1095)
25 1/4 (641)
26 3/4 (680)
37
(940)
4 3/4
(120)
28 1/2 (724)
21 1/4 (540)
Electrical
Case to Case
Connections
FAN
C O
I
L
3 In.
(77 mm)
Required
Air Gap
Refrigeration Outlet
28 5/8
(727)
31
(787)
15
(381)
12 1/8
(308)
6 7/8
(175)
9 3/4 (246)
25 1/4 (641)
2 1/8
(54)
12 7/8
(327)
5 1/8 (130)
Dimensions shown as inches and (mm).
Narrow Footprint, Single Deck, 1 Display Level
Impact
Excel
P1NX-E
Bulk Produce
P1NX-E
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
4 of 5 P1NX-E Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Impact
Excel
P1NX-E
Bulk Produce
Electrical Data
4 ft 6 ft 8 ft 10 ft 12 ft
Number of Fans – 4W 12233
Amperes Watts
4 ft 6 ft 8 ft 10 ft 12 ft 4 ft 6 ft 8 ft 10 ft 12 ft
Evaporator Fans
120V 60Hz Standard 0.31 0.62 0.62 0.93 0.93 24 48 48 72 72
120V 50Hz Standard 0.38 0.76 0.76 1.14 1.14 27 54 54 81 81
230V 60Hz Export 0.15 0.30 0.30 0.45 0.45 24 48 48 72 72
230V 50Hz Export 0.18 0.36 0.36 0.54 0.54 27 54 54 81 81
120V 60Hz Energy Efficient 0.12 0.24 0.24 0.36 0.36 8 16 16 24 24
230V 60Hz Energy Efficient 0.06 0.12 0.12 0.18 0.18 8 16 16 24 24
Minimum Circuit Ampacity
120V 60Hz Standard 0.51 0.82 0.82 1.13 1.13
120V 50Hz Standard 0.58 0.96 0.96 1.34 1.34
230V 60Hz Export 0.35 0.50 0.50 0.65 0.65
230V 50Hz Export 0.38 0.56 0.56 0.74 0.74
120V 60Hz Energy Efficient 0.32 0.44 0.44 0.56 0.56
230V 60Hz Energy Efficient 0.26 0.32 0.32 0.38 0.38
Maximum Over Current Protection 120V 20 20 20 20 20
Maximum Over Current Protection 230V 15 15 15 15 15
Page 5
5 of 5P/N 0480163_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact
Excel
P1NX-E
Bulk Produce
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
4 ft 6 ft 8 ft 10 ft 12 ft (each)
lb (kg) 500 (227) 700 (318) 900 (408) 950 (431) 1000 (454) 50 (23)
4
Actual weights will vary according to optional kits included.
Defrost
Termination
Thermostat
2
To Condensing Unit
}
Dark Blue
Light
Blue
3
Refrigeration
Thermostat
= 120V POWER = 120V NEUTRAL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS GRAYED COMPONENTS IN 12 FOOT MODELS ONLY.
120V
N
EUTRAL
120V
P
OWER
Fans
1
BROWN BAND
BROWN BAND
4 ft 6 ft
8 ft 10 ft 12 ft
Fan Wiring
Offtime Defrost
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 0.78 ft3 /ft (0.07 m3 /m)
AHRI Total Display Area
2
(Sq Ft/Ft) 2.22 ft2/ft (0.68 m2 /m)
Shelf Area 3(Sq Ft/Ft) 2.11 ft2/ft (0.64 m2 /m)
1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft
3
/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann
Product Reference Guide. The standard shelf complement for this model is NONE.
Loading...