Hussmann NIM, NIM-4, NIM-6 Installation & Operation Manual

SERIES NIM
Low Temperature Merchandisers
PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT
Hussmann Monterrey, Mexico
Carretera Mexico-Laredo KM. 1009
Cienga de Flores, Nuevo Leon 65550
Mexico Phone: (52) 81-8318-6400 Fax: (52) 81-8318-6496
Installation &
P/N 2402195
NIM-6 January 2003
TABLE OF CONTENTS
Page
Introduction 1 Inspection 1 Location 1 Clearance 1 Shipping Braces 1 Placement of Doors 1 Leveling of the Cabinet 2 Sealing Splashguard to Floor 2 Grills 2 Drain 3 Tempered Glass Doors 3 Display Pan 3 Air Distribution 3 Electric connections 4 Serial plate 4 Control of temperature 4 Defrost time Clock 4 Maintenance 5 Technical Data Sheets 5
IMPORTANT KEEP IN STORE FOR FUTURE REFERENCE
INTRODUCTION
The NIM – 6 and NIM-4 are low temperature self-contained cabinets, designed for pre-packaged frozen foods or Novelty Ice Cream products.
Design features include self closing glass doors, CFC Free insulating foam, low rail height for ease of access, and a balanced refrigeration system for optimum energy savings.
INSPECTION
a) General All the cabinets should be thoroughly examined to detect damages before and during unloading from the delivering carrier.
This cabinet has been inspected carefully at our factory. Any claim for loss or damage must be made to the carrier. The carrier will provide any necessary inspection reports and/or claim forms.
b) Apparent Loss or Damage
If there is an obvious loss or damage, it must be noted on the freight bill or express receipt and signed by the carrier’s agent; otherwise, carrier may refuse claim.
c) Concealed Loss or Damage
When loss or damage is not apparent until after the cabinets is uncrated, retain all packing materials and submit a written request to the carrier for inspection, within 5 days.
LOCATION Avoid locating where the light of the sun is direct, where air conditioning grills exist, or near electric fans, doors, and open windows, that can create currents of air around these cabinets.
CLEARANCE
To prevent sweating on the exterior surfaces, there must be a minimum clearance of 4in. (102mm) between merchandisers, other fixtures and store walls.
SHIPPING BRACES
Move the cabinet as close as possible to its permanent location and then remove all packaging. Check for damage before discarding packaging. Remove all separately packed accessories such and kits.
PLACEMENT OF DOORS
The case doors are packed in cabinet. Install them in the following manner:
1. Install the left door first (interior).
2. Hook the door in the right interior upper corner with the hooks of automatic closing mechanism and push toward the right. (fig.1)
3. Place the top in the interior upper rail leaving at an angle (fig 2.)
4. To align, push up and in to the back bottom rail (fig. 3)
5. Place the right or external door in the same way