4
Specialty Products
ETL Sanitation
These merchandisers are manufactured to meet ANSI/National Sanitation
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
roduct design in connection with any feature of our
roducts. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
40427
ETL Listed
ETL Sanitation
40427
MZ3
1 of 4
MZ3
Technical Data Sheet
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Medium Temp
Discharge Air (F) 28
Evaporator (F) 20
ote: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
tu/hr/ft*
Parallel 400
Conventional 460
Discharge Air (F) -10
Evaporator (F) -20
ote: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
tu/hr/ft*
Parallel 600
Conventional 690
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
Frequency Hrs 8
OFFTIME
Temp Term °F 54
Failsafe Minutes 35
Frequency Hrs 12
OFFTIME
Temp Term °F 54
Failsafe Minutes 30
ELECTRIC or GAS Not Recommended
Merchandiser Drip Pipe (in.) 1 1/2
Merchandiser Liquid Line (in.) 3/8
Merchandiser Suction Line (in.) 5/8
Estimated Charge (lb)***
4ft 1.2
5ft 1.5
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
ound.
GPM PSI
NA NA
6ft 1.8
GLYCOL REQUIREMENTS
Low Temp
DEFROST DATA
Medium Temp
Low Temp
PHYSICAL DATA
Rev A