Item Part # Description Wiring Item #
F
AN ASSEMBLIES
ONLY ENERGY EFFICIENT FANS ARE AVAILABLE
4 Ft, 8 Ft & 12 Ft
A. 16W Energy Efficient Fan Assembly (1)
0477657 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
6 Ft Only
A. 12W Energy Efficient Fan Assembly (1)
0477655 Fan Motor, Evaporator
(MO.4410546)
0463643 Fan Blade (FB.4780648)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
Note: Revision A is original issue.
XtraLife
Page 2
2 of 10 ME5X-GP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Meat and Produce
05-2010
31 5/8
(804)
30 1/4
(766)
42
(1064)
A
41 1/2
(1054)
33 3/4
(857)
Electrical Knockouts
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
Electrical Connection
4 3/4 (120)
26 1/4
(665)
D
C
2 (51)
8 (203)
1
/4 (7)
4 1/4 (108)
12 1/8 (307)
4 1/4 (108)
4 1/4
(108)
41 1/2
(1054)
43 7/8
(1114)
B
Splashguard
ME5X
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
6 ft 8 ft 10 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/
8 (1838) 96
3
/
8 (2448) 120
1
/
2 (3061) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 29 1/2 (750) 41 1/2 (1054) 29 1/2 (749) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/
8 (1114) 43
7
/
8 (1114)
Distance between front legs and splashguard 2
3
/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 60 1/4 (1530) 84 1/4 (2140) 108 1/4 (2750) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 66 1/8 (1680) 90 1/8 (2289) 114 1/4 (2902) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 60 1/4 (1530) 84 1/4 (2140) 108 1/4 (2750) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307)
Back O/S of case to center of waste outlets 31
5
/8 (804) 31 5/8 (804) 31 5/8 (804) 31 5/8 (804)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
Wireway
Dimensions shown as inches and (mm).
Page 3
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
OPTIMAL SHELF LIFE AHRI 1200 RATING POINT
ME5X-GP U
NLIT LIT UNLIT LIT
Discharge Air °F 29 27 37 35
Evaporator °F 24 22 32 30
Unit Sizing °F 22 20 30 28
Btu/hr/ft — Unlit Shelves
Parallel Conventional Parallel Conventional
U
NLIT 1150 1285 945 1055
Add 10 Btu/hr/ft per shelf row for LED fixtures.
† For energy consumption comparison only.
DEFROST DATA
Frequency Hr 4
Defrost Water (lb/ft/day) 9
(± 15% based on case configuration and product loading).
O
FFTIME ME5X-GP
Time (minutes) 25
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
ME5X-GP
CI/CO* 15°F / 5°F
Indoor Unit Only,
Pressure Defrost Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** ME5X-GP
4ft 1.9 lb 30 oz 0.9 kg
6 ft 2.5 lb 40 oz 1.1 kg
8 ft 3.7 lb 59 oz 1.7 kg
12 ft 5.1 lb 82 oz 2.3 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 10
P/N 0516007_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Shown with Optional Shelf Lights
4 3/4 (120)
21 1/4
(540)
40 5/8
(1032)
30 7/8
(785)
78 3/8
(1991)
31 5/8 (804)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
Refrigeration
Outlet
ME5X-GP
30
(762)
53 7/8
(1369)
34 5/8
(878)
FAN
C O
I
L
3 In.
(77 mm)
Required
Air Gap
7 1/4 (183)
7 5/8 (194)
8 7/8
(225)
Electrical
Case to Case
Connections
7 1/4
(184)
Multi-deck with Duct Shelf, 3 to 5 Display Levels, and Front Glass
Excel
ME5X-GP
Extra Life Meat
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Page 4
Electrical Data
4 ft 6 ft 8 ft 12 ft
Number of Fans – 16W 2 4 6
Number of Fans – 12W 4
Amperes Watts
4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft
Evaporator Fans
120V 60Hz Standard Energy Efficient 0.8 1.2 1.6 2.4 60 72 120 180
120V 50Hz Standard Energy Efficient
230V 60Hz Export NA
230V 50Hz Export NA
Minimum Circuit Ampacity
120V 60Hz Standard Energy Efficient 1.0 1.4 1.8 2.6
120V 50Hz Standard Energy Efficient
230V 60Hz Export NA
230V 50Hz Export NA
Maximum Over Current Protection 120V 20 20 20 20
Maximum Over Current Protection 230V 15 15 15 15
Standard Lighting (T-8 fluorescent)
1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85
Additional 2 Row Canopy 0.51 1.02 1.02 1.54 59 118 118 170
Additional 3 Row Canopy 0.77 1.53 1.53 2.31 89 177 177 255
1 Row Rail Light NA — Glass front does not accept rail light
Fluorescent Shelf Lighting is not available on ExtraLife Merchandisers.
EcoShine Multi-deck Canopy Normal CRI — 120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.28 0.41 0.55 0.82 33 49 66 98
3 Rows of Shelves 0.29 0.44 0.58 0.88 35 53 70 105
4 Rows of Shelves 0.39 0.58 0.78 1.17 47 70 93 140
5 Rows of Shelves 0.48 0.73 0.97 1.45 58 87 116 174
EcoShine Multi-deck Canopy High CRI — 120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.32 0.47 0.63 0.93 38 56 75 112
3 Rows of Shelves 0.35 0.53 0.70 1.05 42 63 84 126
4 Rows of Shelves 0.47 0.70 0.93 1.40 56 84 112 168
5 Rows of Shelves 0.58 0.88 1.17 1.75 70 105 140 210
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
4 of 10 ME5X-GP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Excel
ME5X-GP
Extra Life Meat
Page 5
ESTIMATED SHIPPING WEIGHT
4
Case Solid End
6 ft 8 ft 10 ft 12 ft (each)
lb (kg) 1000 (454) 1100 (499) 1300 (590) 1500 (680) 100 (45)
4
Actual weights will vary according to optional kits included.
5 of 10P/N 0516007_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Excel
ME5X-GP
Extra Life Meat
Product Data
Recommended Usable Cube
1
(Cu Ft/Ft) 6.95 ft3 /ft (0.65 m3 /m)
AHRI Total Display Area
2
(Sq Ft/Ft) 4.40 ft2/ft (1.34 m2 /m)
Shelf Area 3(Sq Ft/Ft) 8.36 ft2/ft (2.55 m2 /m)
1
AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
2
Computed using AHRI 1200 standard methodology: Total Display Area, ft2[m2]/Unit of Length, ft [m]
3
Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (2) rows of 16-inch shelves and (2) rows of 18-inch shelves.
PARTS LIST (Continued from Page 1)
Item Part # Description
LED FIXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. EcoShine LED Canopy Fixture (6)
4441720 Front 48-inch 2900K HCRI 4441722 Front 48-inch 3500K HCRI 4441724 Front 48-inch 3500K 4441726 Front 48-inch 4100K 4441721 Rear 48-inch 2900K HCRI 4441723 Rear 48-inch 3500K HCRI 4441725 Rear 48-inch 3500K 4441727 Rear 48-inch 4100K
4441712 Front 36-inch 2900K HCRI 4441714 Front 36-inch 3500K HCRI 4441716 Front 36-inch 3500K 4441718 Front 36-inch 4100K
Item Part # Description
F. (CONTINUED) EcoShine LED Canopy Fixture
4441713 Rear 36-inch 2900K HCRI 4441715 Rear 36-inch 3500K HCRI 4441717 Rear 36-inch 3500K 4441719 Rear 36-inch 4100K
G. EcoShine LED Shelf Fixture (7)
4441590 48-inch 2900K HCRI 4441591 48-inch 3500K HCRI 4441592 48-inch 3500K 4441593 48-inch 4100K
4441586 36-inch 2900K HCRI 4441587 36-inch 3500K HCRI 4441588 36-inch 3500K 4441589 36-inch 4100K
Page 6
2
Refrigeration
Thermostat
To Condensing Unit
}
Light Blue
2, 4 & 6 Fans
120V
N
EUTRAL
B
ROWN BAND
120V
P
OWER
Fans
BROWN BAND
4 ft 6 ft 8 ft
12 ft
1
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring Offtime Defrost
ME5X-GP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
6 of 10
Light Circuits — Fluorescent Fixtures
4
4
3
3
4
4
4
4
Optional
Two Row
Canopy
Connector
BL
BL
W
G
R
BL
W
R
R
R
BL
BL
R
BL
R
R
R
BK
BK
Orange or Tan Band
BK
6 ft or 8 ft 12 ft
Ballast Plug for Optional Light Rail (if applied)
W
BK
Field Connections
Case
Ground
Bar
4 ft
4
3
44
Optional
Two Row
Canopy
W
BL
BL
R
BL
R
R
R
BK
Page 7
7 of 10P/N 0516007_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
R = Red Y = Yellow G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
6
6
6
6
6
6
6
6
6
6
6
6
5
5
5
5
Optional Canopy Lighting
LED Fixtures
Page 8
ME5X-GP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
8 of 10
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
7
7
7
7
7
7
7
R
BL
5
BK
BK
W
W
BL
R
G
4 ft case
6 ft or 8 ft case
12 ft case
(TYP)
Shelf Light
Plug & Receptacle
BK
Connector
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
7
7
7
7
7
7
7
R
BL
5
BK
BK
W
W
BL
R
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
R
BL
7
7
7
7
7
7
7
R
BL
5
BK
BK
W
W
BL
R
R = Red G = Green BL = Blue BK = Black W = White
= 120V P
OWER = 120V NEUTRAL = FIELD GROUND
= CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
W
Connector
Optional Shelf Harness and LED Light Circuits for 3, 4, 5, 6 & 7 Rows of Shelves
Optional Shelf Lighting LED Fixtures
Page 9
9 of 10P/N 0516007_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Excel
ME5X-GP
Extra Life Meat
Lower Rear Panel
Upper Rear Panel
20th
23rd
SHELF CONFIGURATION
This merchandiser is designed for three, four, or five shelves.
Hussmann recommends the top shelf be not more than 16-inches deep.
The Duct Shelf is easier to install if the duct assembly is inserted AFTER the Duct Shelf is installed.
The duct shelf must be installed at a 10– or 15–degree tilt with the bottom hook of each bracket inserted above slot 20 and below slot 23 (counting from the bottom of the interior back panel).
When properly installed, the duct will cover the large moiré pattern in the lower back panel. The duct is designed so that the shelf can move up or down within three positions and still cover the moiré pattern.
After sliding duct in completely, tabs at rear of shelf must be rotated downward to hold the duct in position.
An exploded view of the Duct Shelf Assembly is shown on the next page.
Bottom Hook
18-Inch Shelf
Duct
Mounting Track
Honeycomb
Insert Duct Assembly
Page 10
Exploded View (Rear) of the
Air Shelf Duct Assembly
ME5X-GP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
10 of 10
Push Rivet
Latch
Air Shelf Latch
Air Shelf Duct Assembly
Optional LED Light Bar
18-inch shelf
Mounting Track-LH
Mounting Track-RH
Plastic Push Rivet
Loading...