Hussmann ME5X-GP Specifications

C
B
A
C
D
E
F
G
P/N_0516007_A
ME5X-GP
Technical Data Sheet
NSF
®
Certified
July 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
ONLY ENERGY EFFICIENT FANS ARE AVAILABLE
4 Ft, 8 Ft & 12 Ft
A. 16W Energy Efficient Fan Assembly (1)
0477657 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
6 Ft Only
A. 12W Energy Efficient Fan Assembly (1)
0477655 Fan Motor, Evaporator
(MO.4410546)
0463643 Fan Blade (FB.4780648)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
Note: Revision A is original issue.
XtraLife
2 of 10 ME5X-GP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Meat and Produce
05-2010
31 5/8
(804)
30 1/4
(766)
42
(1064)
A
41 1/2
(1054)
33 3/4
(857)
Electrical Knockouts
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
Electrical Connection
4 3/4 (120)
26 1/4
(665)
D
C
2 (51)
8 (203)
1
/4 (7)
4 1/4 (108)
12 1/8 (307)
4 1/4 (108)
4 1/4
(108)
41 1/2
(1054)
43 7/8
(1114)
B
Splashguard
ME5X
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
6 ft 8 ft 10 ft 12 ft
General
(A) Case Length (without ends or partitions) 72 3/
8 (1838) 96
3
/
8 (2448) 120
1
/
2 (3061) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 29 1/2 (750) 41 1/2 (1054) 29 1/2 (749) 41 1/2 (1054) Distance between edges of center legs NA NA 43 7/
8 (1114) 43
7
/
8 (1114)
Distance between front legs and splashguard 2
3
/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 60 1/4 (1530) 84 1/4 (2140) 108 1/4 (2750) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) 24 (612) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 66 1/8 (1680) 90 1/8 (2289) 114 1/4 (2902) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 60 1/4 (1530) 84 1/4 (2140) 108 1/4 (2750) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307)
Back O/S of case to center of waste outlets 31
5
/8 (804) 31 5/8 (804) 31 5/8 (804) 31 5/8 (804)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
Wireway
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
OPTIMAL SHELF LIFE AHRI 1200 RATING POINT
ME5X-GP U
NLIT LIT UNLIT LIT
Discharge Air °F 29 27 37 35
Evaporator °F 24 22 32 30
Unit Sizing °F 22 20 30 28
Btu/hr/ft — Unlit Shelves
Parallel Conventional Parallel Conventional
U
NLIT 1150 1285 945 1055
Add 10 Btu/hr/ft per shelf row for LED fixtures.
† For energy consumption comparison only.
DEFROST DATA
Frequency Hr 4
Defrost Water (lb/ft/day) 9
(± 15% based on case configuration and product loading).
O
FFTIME ME5X-GP
Time (minutes) 25
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
ME5X-GP
CI/CO* 15°F / 5°F
Indoor Unit Only,
Pressure Defrost Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** ME5X-GP
4ft 1.9 lb 30 oz 0.9 kg
6 ft 2.5 lb 40 oz 1.1 kg
8 ft 3.7 lb 59 oz 1.7 kg
12 ft 5.1 lb 82 oz 2.3 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 10
P/N 0516007_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Shown with Optional Shelf Lights
4 3/4 (120)
21 1/4
(540)
40 5/8
(1032)
30 7/8
(785)
78 3/8
(1991)
31 5/8 (804)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
Refrigeration
Outlet
ME5X-GP
30
(762)
53 7/8
(1369)
34 5/8
(878)
FAN
C O
I
L
3 In.
(77 mm)
Required
Air Gap
7 1/4 (183)
7 5/8 (194)
8 7/8
(225)
Electrical
Case to Case
Connections
7 1/4
(184)
Multi-deck with Duct Shelf, 3 to 5 Display Levels, and Front Glass
Excel
ME5X-GP
Extra Life Meat
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.