Hussmann M5X-GEP Specifications

C
B
A
C
D
E
G
D
F
P/N_0463888_I
M5X-GEP
Technical Data Sheet
NSF
®
Certified
April 2010
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Item Part # Description Wiring Item #
FAN ASSEMBLIES 8 Ft, 10 Ft& 12 Ft
A. 25W Standard Fan Assembly (1)
0501486 Fan Motor, Evaporator
(MO.4410702)
0501484 Fan Blade (FB.4780657) 25W Energy Efficient Fan Assembly (1) 0501485 Fan Motor, Evaporator
(MO.4410701)
0501484 Fan Blade (FB.4780657)
6 Ft and 10 Ft
Only
A. 7W Standard Fan Assembly (1)
0058698 Fan Motor, Evaporator
(MO.4410102)
0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator
(MO.4410545)
0142780 Fan Blade (FB.0142780)
10 Ft uses both.
Item Part # Description Wiring Item #
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
Note: Revision H added EcoShine LED (page 4) and parts (page 5), and revises canopy wiring diagram (page 6). Other changes marked by bar, underline or circle. Revision I restores 4 ft length.
2 of 9 M5X-GEP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Dimensions shown as inches and (mm).
Meat and Produce
10-2004
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical Field Connection
30 1/4
(768)
M5X
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
4 ft 6 ft 8 ft 10 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/
8 (1229) 72
3
/
8 (1838) 96
3
/
8 (2448) 120
1
/
2 (3061) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064) 42(1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) 33 1/2 (851))
Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768)
Distance between edges of external legs and center legs NA 29 1/2 (750) 41 1/2 (1054) 29 1/2 (749) 41 1/2 (1054)
Distance between edges of center legs NA NA NA 43 7/8 (1114) 43 7/8 (1114)
Distance between front legs and splashguard 2
3
/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 108 1/4 (2750) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) 24 (612) 24 (612)
Length of electrical wireway 26
1
/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42
1
/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 114 1/4 (2902) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36 1/4
(921) 60
1
/4
(1530) 84
1
/4
(2140) 108
1
/4
(2750) 132
3
/8
(3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307)
Back O/S of case to center of waste outlets 31
5
/8 (804) 31 5/8 (804) 31 5/8 (804) 31 5/8 (804) 31 5/8 (804)
Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) 26 1/4 (665)
RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203) 8 (203)
Wireway
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
M5X-GEP U
NLIT
LIT
Discharge Air °F 32 30
Evaporator °F 28 26
Unit Sizing °F 26 24
Btu/hr/ft
— Unlit Shelves
‡‡
M5X-GEP Parallel Conventional
U
NLIT 1210 1320
Optional energy efficient motors reduce the
refrigeration load by 46 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
Frequency Hr 6
Defrost Water (lb/ft/day) 9
(± 15% based on case configuration and product loading).
O
FFTIME M5X-GEP
Time (minutes) 35
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO* M5X-GEP
19°F / 9°F
Indoor Unit Only,
Pressure Defrost Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** M5X-GEP
4ft 1.9 lb 30 oz 0.9 kg
6 ft 2.5 lb 40 oz 1.1 kg
8 ft 3.7 lb 59 oz 1.7 kg
10 ft 4.4 lb 70 oz 2.0 kg
12 ft 5.1 lb 82 oz 2.3 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 9
P/N 0463888_I
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
4 3/4 (120)
21 1/4
(540)
40 5/8
(1032)
30 7/8
(785)
78 3/8
(1991)
31 5/8 (804)
30 1/4 (768)
42 (1064)
33 1/2 (851)
26 1/4 (665)
Refrigeration
Outlet
M5X-GEP
30
(762)
53 7/8
(1369)
34 5/8
(878)
FAN
C O
I
L
3 In.
(77 mm)
Required
Air Gap
7 1/4 (183)
7 5/8 (194)
8 7/8
(225)
Electrical
Case to Case
Connections
7 1/4
(184)
Dimensions shown as inches and (mm).
Multi-deck, 5 Display Levels, and Front Glass
Impact
Excel
M5X-GEP
Meat and Delicatessen
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.
Loading...
+ 6 hidden pages