Hussmann M5NX-GEP Specifications

C
B
A
C
D
E
G
D
F
P/N_0486353_D
M5NX-GEP
Technical Data Sheet
NSF
®
Certified
March 2010
Item Part # Description Wiring Item #
F
AN ASSEMBLIES
8 Ft & 12 Ft
A. 12W Standard Fan Assembly (1)
0047000 Fan Motor, Evaporator
(MO.4410103)
0461805 Fan Blade (FB.4780446) 12W Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator
(MO.4410546)
0461805 Fan Blade (FB.4780446)
T
HERMOSTATS
B. Optional Adjustable Refrigeration Thermostat (2)
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
C. Ballast, Electronic (3)
0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677)
D. Fluorescent Lamp (4)
Replace with like fixtures
LED F
IXTURES AND POWER SUPPLY
E. 0501213 Power Supply (EP.4481861) (5)
F. LED Canopy Fixture (6)
Replace with like fixtures — See Page 5.
G. LED Shelf Fixture (7)
Replace with like fixtures — See Page 5.
©2010 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Note: Revision D adds EcoShine LED (page 4) and parts (page 5), and revises Btu note (page 3), canopy wiring diagram (page 6). Other changes marked by bar, underline or circle.
Wireway
Splashguard
26 3/4
(680)
25 1/4
(641)
37
(940)
A
41 1/2
(1054)
28 1/2
(724)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Waste Outlet
Waste Outlet
FRONT
4 3/4 (120)
21 1/4
(540)
D
C
8 (203)
12 1/8 (307)
4 1/4 (108)
41 1/2
(1054)
43 7/8
(1114)
B
19
(483)
NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD.
Electrical
Stub Up Area
6 x 6
(152x152)
Electrical Field Connection
26 1/2
(673)
4 3/4 (120)
4 1/2 (115)
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/
8 (2448) 144
1
/
2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 37 (940) 37 (940)
Back of case to front of splashguard 28 1/2 (724) 28 1/2 (724) Back of case to O/S edge of front leg 25 1/4 (641) 25 1/4 (641) Distance between edges of external legs and center legs 41 1/
2 (1054) 41
1
/
2 (1054)
Distance between edges of center legs NA 43
7
/8 (1114)
Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 19 (483) 19 (483) Length of electrical wireway 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 84 1/
4 (2140) 132
3
/
8 (3363)
RH End of case to the center of RH waste outlet 12
1
/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 26 3/4 (680) 26 3/4 (680) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet 21 1/4 (540) 21 1/4 (540) RH end of case to center of refrigeration outlet 8 (203) 8 (203)
2 of 10 M5NX-GEP Technical Data Sheet
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900
Engineering
Plan Views
Meat / Delicatessen
10-2004
M5NX
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.)
3
/8
Merchandiser Suction Line (in.)
7
/8
Wireway
Dimensions shown as inches and (mm).
REFRIGERATION DATA
Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
M5NX-GEP UNLIT LIT
Discharge Air °F 32 30
Evaporator °F 28 26
Unit Sizing °F 26 24
Btu/hr/ft
— Unlit Shelves
‡‡
M5NX-GEP Parallel Conventional
U
NLIT 1260 1400
Optional energy efficient motors reduce the
refrigeration load by 27 Btu/hr/ft.
‡‡
Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
Frequency Hr 6
Defrost Water (lb/ft/day) 9
(± 15% based on case configuration and
product loading).
O
FFTIME
M5NX-GEP
Time (minutes) 35
E
LECTRIC OR GAS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO* M5NX-GEP
19°F / 9°F
Indoor Unit Only, Pressure Defrost
Termination* 48°F
*Use a Temperature Pressure Chart to determine PSIG conversions.
Estimated Charge** M5NX-GEP
8 ft 3.7 lb 59 oz 1.7 kg
12 ft 5.1 lb 82 oz 2.3 kg
**This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
3 of 10
P/N 0486353_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
4 3/4 (120)
25
(635)
21 1/4
(540)
40 1/4
(1022)
30 7/8
(785)
Refrigeration
Outlet
53 7/8
(1369)
34 5/8
(878)
FAN
C O
I
L
M5NX-GEP
3 In. (77 mm)
Required
Air Gap
7 1/4 (183)
7 5/8 (194)
8 7/8
(225)
Electrical
Case to Case
Connections
26 3/4 (680)
25 1/4 (641)
37 (940)
28 1/2 (724)
21 1/4 (540)
78 3/8
(1991)
7 1/4
(184)
Dimensions shown as inches and (mm).
Narrow Footprint, Multi-deck, 5 Display Levels, and Front Glass
Impact
Excel
M5NX-GEP
Meat and Delicatessen
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.