Hussmann M5NGE Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0404844A
Item Part # Description Wiring Item # F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly 1
0047000 Fan Motor, Evaporator 0315470 Fan Blade
B. 0411744 Standard Non-adjustable 2
Thermostat
C. 0137880 Optional Adjustable 3
Refrigeration Thermostat
Note: Changed items have been underlined.
Merchandisers
®
D
E
E
A
E
C
B
D
M5NGE
Data Sheet Set
P/N 0404844A
NSF
®
Certified
August 2004
Item Part # Description Wiring Item # L
AMPS AND BALLASTS
D. 0428648 Ballast, Electronic
2 lamps 4
D. 0428649 Ballast Electronic
3 lamps 4
E. Fluorescent Lamp 5
Replace with like fixtures
Page 2
8 Ft 12 ft
General
(A) Length of Case (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
Maximum outside dimensions of case back to front (includes bumper) 40 1/2
(1030) 40
1
/2
(1030)
Back of case to front of splashguard 33
1
/2 (851) 33 1/2 (851) Back of case to outside edge of rear skidrail 4 3/8 (111) 4 3/8 (111) Back of case to outside edge of front skidrail 29 1/2
(749) 29
1
/2
(749)
Width of skidrail 4
1
/2 (114) 4 1/2 (114)
Stub-up area between front skidrail and splashguard 4 (102) 4 (102)
Electrical Service
(B) Right end of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467)
Back outside of case to center of knockout 31 (787) 31 (787) Length of electrical raceway 34 1/2 (878) 34 1/2 (878)
*Note: Electrical Field Wiring Connection Point
Waste Outlet
(C) Right end of case to center of waste outlet 24 1/8 (613) 72 1/4 (1835)
Left end of case to center of waste outlet 72 1/4 (1835) 72 1/4 (1835) Back outside of case to center of waste outlet 27 (686) 27 (686)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of drip pipe 1 1/2 (38) 1 1/2 (38) *Note: Water seal outlet must clear front skid rail.
Refrigeration Outlet
Right end of case to center of refrigeration outlet 9 (230) 9 (230) Back outside of case to center of refrigeration outlet 27 1/2 (699) 27 1/2 (699)
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
M5NGE Data Sheet
4 (102)
9
(230)
27 1/2
(699)
27
(686)
B
C
Skid/ External Base
A
72
1/4 (1835)
4 3/8 (111)
Refrigeration
Outlet
Waste Outlet
Water Seal
Electrical
31
(787)
Access Area
40 1/2
(1030)
Front
(See Note*)
29 1/2
(749)
33 1/2
(851)
Dimensions shown as inches and (mm).
Engineering
Plan View
Narrow
Meat and Delicatessen
09-2003
Page 3
P/N 0404844A
3 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
5 5/8 (142)
FAN
M5NGE
38
(966)
30
(762)
7 1/2
(190)
53 5/8
(1363)
24 1/4
(617)
16
(406)
14
(356)
42 1/4
(1074)
18 1/8
(461)
C O
I
L
9 1/4
(234)
4 3/8
(111)
27 (686)
27 1/2 (699)
29 1/2 (748)
33 7/8 (861)
40 5/8 (1031)
77 7/8
(1978)
Refrigeration Outlet
18 1/8
(461)
REFRIGERATION DATA
Note: This data is based on store
temperature and humidity that does not exceed 75°F and 55% R.H.
M5NE Discharge Air °F 29 Evaporator °F 21 Unit Sizing °F 19
Btu/hr/ft** M5NE Parallel 1470 Conventional 1575
**For all refrigeration equipment other than Husssmann, use conventional BTU values.
DEFROST DATA
M5NE Frequency (hr) 6 Defrost Water (lb/ft/day) 9
(±15% based on case configuration and product loading.
O
FFTIME
M5NE Temp Term °F 48°F Failsafe Minutes 30
E
LECTRIC OR G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO** 14/4°F
Indoor Unit Only, Pressure Defrost Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
M5NE Drip Pipe (in.) 1
1
/2
Liquid Line (in.)
3
/8
Suction Line (in.)
7
/8
Estimated Charge (lbs)***
M5NE 8 ft 2.7 12 ft 3.9
***This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound.
Length (in.) Added to Lineup by Each End or Insulated Partition 1
1
/2
Impact M5NGE
Narrow
Meat and Delicatessen
Multi-deck, 5 Display Levels and Front Glass
Dimensions shown as inches and (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements.
Page 4
4 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
M5NGE Data Sheet
Impact M5NGE
Narrow Meat and Delicatessen
Electrical Data
8 Ft 12 Ft
Number of Fans — 9W 2 3
Amperes Watts
Merchandiser 8 Ft 12 Ft 8 Ft 12 Ft
Fans
Standard (120V 60Hz) 1.40 2.10 110 165
Energy Efficient (120V 60Hz) 0.76 1.14 50 75
Export (230V 50Hz) 0.76 1.14 114 171
Constant on Anti-sweat Heaters NA
Cycling Anti-sweat Heaters NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 1.60 2.30
Export (230V 50Hz) 0.96 1.34
With Energy Efficient Fans (120V 60Hz) 0.96 1.34
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Supplemental Gas Heaters NA
208V 1ΦΦElectric Defrost NA
Standard Lighting
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Rail 1.02 1.54 118 170
2 Rows Canopy 1.02 1.54 118 170
2 Rows Canopy and 1 Row Rail 1.53 2.31 177 255
Optional Shelf Lighting
1 Row of Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255
Page 5
P/N 0404844A
5 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Defrost
Termination
Thermostat
Refrigeration
Thermostat
Dark Blue
3
To Condensing Unit
}
Light Blue
2
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V P
OWER = 120V NEUTRAL = Field GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring
Offtime Defrost
2 & 3 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
B
ROWN BAND
= Case GROUND
Connector
Connector
G
Connector
Connector
Connector
Connector
Connector
Optional Shelf Harness and Light Circuits for One Row of Shelves
120 V
Power
B
W
G
B
BL
BL
BL
G
G
R
R
BL
BL G
W
BL
Shelf Harness
Shelf Light Circuits
BL
G
R
5
4
W
BL
R
5
BL
R
G
G
R
R
R
G
Shelf Lighting
G G
R
BL
5
BL
Connector
Connector
B
Page 6
M5NGE Data Sheet
6 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting 1 Row Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
Optional Lighting 2 Row Canopy
120V NEUTRAL
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
ORANGE OR TAN BAND
B
B
4
W
4
W
4
BL
R
BL
BL
BL
R
BL
BL
BL
R
R
BL
R
BL
R
R
5
R
5
R
5
Optional Lighting 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
B
Light
Switch
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
W
4
R
BL
BL
WARNING
Grayed components in 12 foot models only.
= 120V POWER = 120V NEUTRAL
BL
R
R
5
Loading...