![](/html/9f/9fe4/9fe4fbaf9afc99275218e92d14dca4b642be80b7a9a103ebcb0d3312ed2770f2/bg1.png)
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0404844A
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly 1
0047000 Fan Motor, Evaporator
0315470 Fan Blade
embossing toward motor
B. 0411744 Standard Non-adjustable 2
Thermostat
C. 0137880 Optional Adjustable 3
Refrigeration Thermostat
Note: Changed items have been underlined.
M5NGE
Data Sheet Set
P/N 0404844A
NSF
®
Certified
August 2004
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. 0428648 Ballast, Electronic
2 lamps 4
D. 0428649 Ballast Electronic
3 lamps 4
E. Fluorescent Lamp 5
Replace with like fixtures
![](/html/9f/9fe4/9fe4fbaf9afc99275218e92d14dca4b642be80b7a9a103ebcb0d3312ed2770f2/bg2.png)
8 Ft 12 ft
General
(A) Length of Case (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
Maximum outside dimensions of case back to front (includes bumper) 40 1/2
(1030) 40
1
/2
(1030)
Back of case to front of splashguard 33
1
/2 (851) 33 1/2 (851)
Back of case to outside edge of rear skidrail 4 3/8 (111) 4 3/8 (111)
Back of case to outside edge of front skidrail 29 1/2
(749) 29
1
/2
(749)
Width of skidrail 4
1
/2 (114) 4 1/2 (114)
Stub-up area between front skidrail and splashguard 4 (102) 4 (102)
Electrical Service
(B) Right end of case to center of farthest knockout 88 3/8 (2245) 136 1/2 (3467)
Back outside of case to center of knockout 31 (787) 31 (787)
Length of electrical raceway 34 1/2 (878) 34 1/2 (878)
*Note: Electrical Field Wiring Connection Point
Waste Outlet
(C) Right end of case to center of waste outlet 24 1/8 (613) 72 1/4 (1835)
Left end of case to center of waste outlet 72 1/4 (1835) 72 1/4 (1835)
Back outside of case to center of waste outlet 27 (686) 27 (686)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102)
Outside diameter of drip pipe 1 1/2 (38) 1 1/2 (38)
*Note: Water seal outlet must clear front skid rail.
Refrigeration Outlet
Right end of case to center of refrigeration outlet 9 (230) 9 (230)
Back outside of case to center of refrigeration outlet 27 1/2 (699) 27 1/2 (699)
2 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
M5NGE Data Sheet
4 (102)
9
(230)
27 1/2
(699)
27
(686)
B
C
Skid/ External Base
A
72
1/4 (1835)
4 3/8 (111)
Refrigeration
Outlet
Waste Outlet
Water Seal
Electrical
31
(787)
Access Area
40 1/2
(1030)
Front
(See Note*)
29 1/2
(749)
33 1/2
(851)
Dimensions shown as inches and (mm).
Engineering
Plan View
Narrow
Meat and Delicatessen
09-2003