Hussmann M5GEPLUS Datasheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
A
B
C
C
D
D
D
P/N 0457238A
Merchandisers
Note: Changed items have been underlined.
M5GEPLUS
P/N 0457238A
NSF
®
Certified
March 2004
Item Part # Description Wiring Item #
F
AN A
SSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0380485 Fan Blade
embossing toward motor
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND
BALLASTS
D. 0428648 Ballast, Electronic
2 lamps (4)
D. 0428649 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
®
8 ft 12 ft
General
(A) Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670)
Maximum O/S dimension of case back to front (includes bumper) 46 5/
8 (1184) 46
5
/
8 (1184)
Back of case to front of splashguard 35
3
/
8 (897) 35
3
/
8 (897)
Back of case to O/S edge of front skid rail 29
3
/8 (747) 29 3/8 (747) Width of skid rail 4 1/2 (114) 4 1/2 (114) Right-hand end of case to inside edge of external support 5 1/
2 (140) 5
1
/
2 (140)
Distance between edges of external support and center support 40
5
/8 (1032) 40 5/8 (1032) Distance between edges of center supports NA 44 (1118) Stub-up area between front skid rail and splashguard 4 1/
2 (114) 4
1
/
2 (114)
Electrical Service (Electrical Field Wiring connection point)
(B) Right-hand end of case to center of farthest knockout 88
3
/8 (2245) 136 1/2 (3467) Back of case to center of knockout 30 1/2 (775) 30 1/2 (775) Length of electrical raceway 31 5/8 (803) 31 5/8 (803)
Waste Outlet
(C) Right-hand end of case to the center of waste outlet 24 1/8 (613) 72 1/4 (1835)
Left-hand end of case to the center of waste outlet 72 1/4 (1835) 72 1/4 (1835) Back outside of case to center of waste outlet 27 5/8 (703) 27 5/8 (703)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet 30 5/8 (778) 30 5/8 (778)
(D) Right-hand end of case to center of refrigeration outlet 9 (230) 9 (230)
2 of 6 M5GEP
LUS
Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
Meat &
Delicatessen
09-2003
30 1/2
(775)
Electrical
A
40 5/8
(1032)
4 1/2 (114)
B
72 1/4 (1835)
Waste Outlet
Water Seal
(see note)
FRONT
4 1/8 (105)
27 5/8
(703)
40 5/8
(1032)
C
4
(102)
Refrigeration
Outlet
5 1/2 (140)
1 3/8 (35)
4 1/2 (114)
29 3/8
D
(747)
30 5/8
(778)
35 3/8
(897)
46 1/4
(1174)
Loading...