Electrical Data
8 ft 12 ft
Number of Fans—12W 2 3
Amperes Watts
8 ft 12 ft 8 ft 12 ft
Evaporator Fan
120V 60Hz Standard 1.30 1.95 100 150
120V 50Hz Standard 1.50 2.25 114 171
230V 60Hz Export 0.66 0.99 100 150
230V 50Hz Export 0.76 1.14 114 171
120V 60Hz Energy Efficient 0.60 0.90 36 54
230V 60Hz Energy Efficient 0.30 0.45 36 54
Minimum Circuit Ampacity
120V 60Hz Standard 1.50 2.15
120V 50Hz Standard 1.70 2.45
230V 60Hz Export 0.86 1.19
230V 50Hz Export 0.96 1.34
120V 60Hz Energy Efficient 0.80 1.10
230V 60Hz Energy Efficient 0.50 0.65
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Standard Lighting (T-8 fluorescent)
1 Row Canopy 0.51 0.77 59 85
Optional Lighting (T-8 fluorescent)
Additional 1 Row Canopy 0.51 0.77 59 85
Additional 2 Row Canopy 1.02 1.54 118 170
Additional 3 Row Canopy 1.53 2.31 177 255
1 Row Rail Light NA — Glass front does not accept rail light
1 Row of Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255
4 Rows of Shelves 2.04 3.08 236 340
EcoShine Multi-deck — Normal CRI—120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.55 0.82 66 98
2 Rows of Shelves 0.39 0.58 47 70
3 Rows of Shelves 0.58 0.88 70 105
4 Rows of Shelves 0.78 1.17 93 140
EcoShine Multi-deck — High CRI — 120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.63 0.93 75 112
2 Rows of Shelves 0.47 0.70 56 84
3 Rows of Shelves 0.70 1.05 84 126
4 Rows of Shelves 0.93 1.40 112 168
Always*Bright Multi-deck Lighting — 120VAC, 50/60Hz
2 Row Canopy (Front & Rear) 0.71 1.08 85 130
2 Rows of Shelves 0.47 0.67 56 80
3 Rows of Shelves 0.74 1.11 89 133
4 Rows of Shelves 0.93 1.40 112 168
120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52
4 of 10 M4NX-GEP Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
Excel
M4NX-GEP
Meat and Delicatessen