Hussmann M4GEPLUS Datasheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0457236B
Note: Changed items have been underlined
.
Merchandisers
®
M4GEPLUS
Data Sheet Set
P/N 0457236B
NSF
®
Certified
March 2005
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0407532 Fan Blade
embossing toward motor
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. 0428648 Ballast, Electronic
2 lamps (4)
D. 0428649 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
2 of 6
M4GEPLUS Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical
Refrigeration
4 1/8 (105)
72 1/4 (1835)
5
1
/2 (140)
1
3
/8 (35)
4
1
/2 (114)
29 1/2 (749)
35
1
/8
(891)
46
1
/4
(
1174)
9
(230)
30
5
/8
(778)
27
1
/2
(699)
40
5
/8
(1032)
4 (102)
Water Seal
Waste Outlet
4 (102)
40
5
/8
(1032)
30
1
/2
(775)
A
B
C
Front
Dimensions shown as inches and (mm).
8 Ft 12 ft
General
(A) Length of Case (without ends or partitions) 96
3
/8 (2448) 144 1/2 (3670)
Maximum outside dimensions of case back to front (includes bumper) 46
1
/
4 (1174) 46
1
/
4 (1174)
Back of case to front of splashguard 35
1
/8 (891) 35 1/8 (891)
Back of case to outside edge of front skidrail 29
1
/2 (749) 29 1/2 (749)
Width of skidrail 4
1
/
2 (114) 4
1
/
2 (114)
Right end of case to inside edge of external support 5
1
/2 (140) 5 1/2 (140)
Distance between inside edges of external support and center support 40
5
/8 (1032) 40 5/8 (1032) Distance between inside edges of center supports NA 44 (1118) Width of external support 4
1
/8 (105) 4 1/8 (105) Stub-up area between front skidrail and splashguard 4 (102) 4 (102) Right edge of case (excluding end) to inside edge of external support 1
3
/8 (35) 1 3/8 (35)
Electrical Service (Electrical Field Wiring connection point)
(B) Right end of case to center of farthest knockout 88
3
/8 (2245) 136 1/2 (3467) Back outside of case to center of knockout 30
1
/2
(775) 30
1
/2
(775)
Length of electrical raceway 34
1
/2 (878) 34 1/2 (878)
Waste Outlet
(C) Right end of case to center of waste outlet 24
1
/8 (613) 72 1/4 (1835)
Left end of case to center of waste outlet 72
1
/4 (1835) 72 1/4 (1835) Back outside of case to center of waste outlet 27
1
/2
(699) 27
1
/2
(699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of drip pipe 1
1
/2 (38) 1 1/2 (38)
Refrigeration Outlet
Right end of case to center of refrigeration outlet 9 (230) 9 (230) Back outside of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778)
Engineering
Plan View
Meat and Produce
12-2003
Loading...
+ 4 hidden pages