Hussmann M4GEPLUS Datasheet

Page 1
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0457236B
Note: Changed items have been underlined
.
Merchandisers
®
M4GEPLUS
Data Sheet Set
P/N 0457236B
NSF
®
Certified
March 2005
Item Part # Description Wiring Item #
F
AN ASSEMBLIES AND THERMOSTATS
A. 9W Fan Assembly (1)
0047000 Fan Motor, Evaporator 0407532 Fan Blade
embossing toward motor
C. 0137880 Optional Adjustable (3)
Refrigeration Thermostat
Item Part # Description Wiring Item #
L
AMPS AND BALLASTS
D. 0428648 Ballast, Electronic
2 lamps (4)
D. 0428649 Ballast, Electronic
3 lamps (4)
E. Fluorescent Lamp (5)
Replace with like fixtures
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.
Page 2
2 of 6
M4GEPLUS Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Electrical
Refrigeration
4 1/8 (105)
72 1/4 (1835)
5
1
/2 (140)
1
3
/8 (35)
4
1
/2 (114)
29 1/2 (749)
35
1
/8
(891)
46
1
/4
(
1174)
9
(230)
30
5
/8
(778)
27
1
/2
(699)
40
5
/8
(1032)
4 (102)
Water Seal
Waste Outlet
4 (102)
40
5
/8
(1032)
30
1
/2
(775)
A
B
C
Front
Dimensions shown as inches and (mm).
8 Ft 12 ft
General
(A) Length of Case (without ends or partitions) 96
3
/8 (2448) 144 1/2 (3670)
Maximum outside dimensions of case back to front (includes bumper) 46
1
/
4 (1174) 46
1
/
4 (1174)
Back of case to front of splashguard 35
1
/8 (891) 35 1/8 (891)
Back of case to outside edge of front skidrail 29
1
/2 (749) 29 1/2 (749)
Width of skidrail 4
1
/
2 (114) 4
1
/
2 (114)
Right end of case to inside edge of external support 5
1
/2 (140) 5 1/2 (140)
Distance between inside edges of external support and center support 40
5
/8 (1032) 40 5/8 (1032) Distance between inside edges of center supports NA 44 (1118) Width of external support 4
1
/8 (105) 4 1/8 (105) Stub-up area between front skidrail and splashguard 4 (102) 4 (102) Right edge of case (excluding end) to inside edge of external support 1
3
/8 (35) 1 3/8 (35)
Electrical Service (Electrical Field Wiring connection point)
(B) Right end of case to center of farthest knockout 88
3
/8 (2245) 136 1/2 (3467) Back outside of case to center of knockout 30
1
/2
(775) 30
1
/2
(775)
Length of electrical raceway 34
1
/2 (878) 34 1/2 (878)
Waste Outlet
(C) Right end of case to center of waste outlet 24
1
/8 (613) 72 1/4 (1835)
Left end of case to center of waste outlet 72
1
/4 (1835) 72 1/4 (1835) Back outside of case to center of waste outlet 27
1
/2
(699) 27
1
/2
(699)
Water Seal
Edge of water seal to center of waste outlet 4 (102) 4 (102) Outside diameter of drip pipe 1
1
/2 (38) 1 1/2 (38)
Refrigeration Outlet
Right end of case to center of refrigeration outlet 9 (230) 9 (230) Back outside of case to center of refrigeration outlet 30
5
/8 (778) 30 5/8 (778)
Engineering
Plan View
Meat and Produce
12-2003
Page 3
3 of 6
P/N 0457236B
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
C O
I
L
FAN
38 1/8
(969)
7
1
/2
(152)
3
1
/8
(079)
4 (102)
36 1/2
(926)
46 1/2
(1181)
73 7/8
(1877)
40 3/4
(1035)
12 5/8
(319)
27 1/2 (699)
29 1/2 (749)
35 1/4 (897)
46 1/2 (1180)
33 3/8
(847)
11 3/8
(289)
30 1/8
(766)
39 7/8
(1012)
4
1
/
2
(114)
4
(102)
21 1/2
(548)
13 1/4
(337)
M4GEPLUS
Impact M4GEPLUS
Meat and Delicatessen
Multi-deck, 4 Display Levels, and Front Glass
Dimensions shown as inches and (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF
®
) Standard #7 requirements.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and 55% R.H.
M4GEP
LUS UNLIT LIT
Discharge Air °F 31 29
Evaporator °F 28 26
Unit Sizing °F 26 24
Btu/hr/ft* M4GEP
LUS
UNLIT LIT
Parallel 1000 1045
Conventional 1090 1140
*For all refrigeration equipment other than Hussmann, use conventional Btu values.
DEFROST DATA
Frequency Hrs 6
Defrost Water (lb/ft/day) 8
(± 15% based on case configuration and product
loading).
OFFTIME M4GEPLUS
Time (minutes) 35
ELECTRIC OR GAS Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO** M4GEP
LUS
19°F / 9°F
Indoor Unit Only, Pressure Defrost
Termination** 48°F
**Use a Temperature Pressure Chart to determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.) 1 1/2
Liquid Line (in.)
3
/8
Suction Line (in.)
7
/8
Estimated Charge (lb)***
M4GEP
LUS
8 ft 3.1
12 ft 4.5
***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound.
Length Added to Lineup by
Each End (in.) 1
1
/2
Each Insulated Partition (in.) 1 1/2
Page 4
4 of 6
M4GEPLUS Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
M4GEPLUS
Meat and Delicatessen
Electrical Data
8 Ft 12 Ft
Number of Fans — 9W 4 6
Amperes Watts
Merchandiser 8 Ft 12 Ft 8 Ft 12 Ft
Fans
Standard (120V 60Hz) 2.80 4.20 220 330
Energy Efficient (120V 60Hz) 1.52 2.28 100 150
Export (230V 50Hz) 1.52 2.28 228 342
Constant on Anti-sweat Heaters NA
Cycling Anti-sweat Heaters NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 3.00 4.40
Export (230V 50Hz) 1.72 2.48
With Energy Efficient Fans (120V 60Hz) 1.72 2.48
Maximum Over Current Protection 120V 20 20
Maximum Over Current Protection 230V 15 15
Supplemental Gas Heaters NA
208V 1ΦΦElectric Defrost NA
Standard Lighting
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Rail 1.02 1.54 118 170
2 Row Canopy 1.02 1.54 118 170
2 Row Canopy and 1 Row Rail 1.53 2.31 177 255
3 Row Canopy 1.53 2.31 177 255
3 Row Canopy and 1 Rail 2.04 3.08 236 340
Optional Shelf Lighting
1 Row of Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255
Page 5
P/N 0457236B
5 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Refrigeration
Thermostat
2
To Condensing Unit
}
Light Blue
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
=
120V POWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring
Offtime Defrost
4 & 6 Fans
120V NEUTRAL
B
ROWN BAND
120V POWER
Fans
1
BROWN BAND
Connector
Connector
G
Connector
Connector
Connector
Connector
Connector
Optional Shelf Harness and Light Circuits for One Row of Shelves
120 V Power
B
W
G
B
BL
BL
BL
G
G
R
R
BL
BL G
W
BL
Shelf Harness
Shelf Light Circuits
BL
G
R
4
3
W
BL
R
4
BL
R
G
G
R
R
R
G
Shelf Lighting
G G
R
BL
4
BL
Connector
Connector
B
Page 6
M4GEPLUS Data Sheet
6 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Light Circuits
Standard Lighting 1 Row Canopy or Optional 1 Row Rail
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
3
Optional Lighting 2 Rows Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
B
W
3
W
B
3
Optional Lighting 3 Row Canopy
120V NEUTRAL
ORANGE OR TAN BAND
120V POWER
ORANGE OR TAN BAND
Light
Switch
W
B
B
B
3
W
3
W
3
BL
R
BL
44
BL
R
BL
4
BL
R
BL
44
BL
R
BL
4
BL
R
BL
4
R
BL
BL
4
BL
R
BL
R
4
BL
R
BL
R
4
BL
R
4
BL
R
4
R
4
R
4
R
4
R
4
R
4
R
4
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
C
IRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER
= 120V NEUTRAL
Loading...